This manual is effective for all filters of the type series  DNR 405-635, DNR 630, DNR 1001-8201, DNR 1005-8205, DNA 250-2050, 
DNL  630,  EDNR,  EDNA  and  EDNL  and  related  specifications.  It  contains  certain  requirements  and  instructions  which  ensure 
unobjectionable operation of the filter. It can be completed with specific additional instructions by the operator himself if necessary. 
The pressure filters listed above are intended for the filtering of liquid media. 

1. Safety instructions

 

 

-  Prior to operating the filter, manual and maintenance instructions have to be read carefully. 
-  Follow the instructions of this manual under any circumstances! 
-  The manufacturer does not assume liability for any damage, which occurs due to disregarding these instructions. 
-  If operations are carried out differently, the safety of the pressurized device can not be assured! 
-  Operating  conditions  given  in  the  data  sheet,  especially  excess  pressure,  temperature  range  and  operating  fluid,  have  to  be 
  followed unconditionally. Variation of these parameters can cause damage to important pressure holding parts and sealing. Also 
  take in consideration the compatibility of filter components with the operating fluid. 
-  Under working conditions the filter housing is pressurized. Do not try to loosen or remove any part of the filter or the filter housing 
  during operation. The operating fluid could escape at high pressure and high temperatures. 
 

This does not apply for parts of the decompressed or the turned off side of the filter (see „Maintenance“). 

-  Leaking operating fluid always bears the danger of injuries and burns! 
-  Do not open the filter housing until you made sure it is not pressurized any more! 
-  Touching parts of the filter may cause burning, depending on the operating temperature. 
-  When exchanging the filter keep in mind that it might have operating temperature. Danger of burning! 
-  Always wear safety goggles and gloves when working on the filter! 
-  If you come into contact with the operating fluid please follow the instructions of the fluid manufacturer!!  
- Only use original spare parts. 

 

 

2. Installation

 

 

The  filter  is  supplied  and  delivered  ready  to  be  installed.  The  fitting  position  of  the  filter  is  vertical.  The  filter  has  to  be  fitted  with 
fastening screws in size and amount according to the corresponding fastening bore holes of the filter housings. The fitting of the filter 
has to be carried out in the way that the least possible transmission of tensible forces on the filter housing and the change-over valve 
is given. The connection of the pipework has to be made with flanges for pipework. 
Ensure upon assembling that 

 

- no dirt and no impurities of foreign fluids penetrate the filter 
- the connections for input and output are correctly connected to the pipe system 
- the pipe system is connected with the filter; as stress-free as possible 
- the extension to demount and the accessibility to the service elements is guaranteed 

 

Filter with electrical respectively electronical clogging indicators have to be installed according to the unit specific conditions and 
according to the technical parameters of the corresponding data sheets. 

 

3. Commissioning

 

 

Before commissioning the completeness of the filter (filter elements and seals) and the cleanness have to be controlled. 
Air bleeding of the controlled filter has to be carried out to the following instructions: 

 

-  The positioning pin of the selector shaft has to be located in the middle position 
-  Opening  of  the  air-bleed  screws  or  air-bleed  connections  (air-bleed  connections  according  to  data  sheet  1651  and 
  connection of suitable airbleeding tubes with collecting pan for the flow out of the operating fluid 
-  Connection of the unit volume flow (reduced volume flow; from 10 to 50 l/min) until bubble-free operating fluid flows out of both 
  airbleeding tubes 
-  Disconnection of the unit volume flow 
-  Remove  the  airbleeding  tubes  and  close  the  air-bleed  bore  holes  or  air-bleed  connections  (air-bleed  connections 
  according to data sheet 1651) 
-  Connection to the required filter side at the positioning pin of the selector shaft 
 
  Take a look at the indicating labels and change-over indications at the filter. 

 

4. Change of Elements

 

 

The  changing  of  the  filter  elements  is  necessary  when  reaching  the  unit  specific  pressure  difference  respectively  reaching  the 
maximum  pressure  difference  given  by  the  clogging  indicator.    If  there  is  no  unit  specific  definition,  the  change  of  the  elements 
should be done at a maximum of  p 6 bar. 
The filter element can be changed during operation. This has to be carried out as follows: 
-  Opening of the pressure balance valve 
-  Switching over the positioning pin from the operating side through the other side 
  (Take a look at the indicating labels and change-over indications at the filter) 
-  Closing the pressure balance valve 
-  Connect  the  air-bleed  and  the  drain  plug  of  filter  side  to  be  maintained  with  suitable  pipes  and  place  a  collecting  pan  for  the 
  operating fluid flowing out 

 

 
 
 
 

 

 
 
 
 
 
 
 

 

Manual and maintenance instructions 

for INTERNORMEN-Pressure filter, change-over  
DNR, DNA, DNL, EDNR, EDNA, EDNL, relatd specifications

 

 

Sheet No. 

21682-4D

 

Page 1/3

 

 