Summary of Contents for HMi VU Series

Page 1: ...tion Leaflet Instruction Leaflet IL04801003E Effective February 2012 Contents Description Page Preface 1 Safety Precautions 1 Installation 3 Wiring 4 Basic Inspection 4 Hardware Features 7 Panel Cut Out 15 Specifications 17 ...

Page 2: ...t guide may be revised without notice Please consult an authorized distributor or download the most up to date version at www eaton com oi Carefully note and observe the following safety precautions when receiving inspecting installing operating maintaining and troubleshooting The following words DANGER WARNING and STOP are used to mark safety precautions when using Eaton s operator interface Fail...

Page 3: ...damage to unit Accessing the unit s internal electric assemblies will void the warranty In addition an electrical charge with hazardous voltages may reside in the operator interface after power has been removed for 10 minutes or longer which may result in electrical shock and damage to the unit Turn the power off before changing backup battery and check system settings after changes are made Note ...

Page 4: ...sent and properly aligned Step 2 Insert fasteners into the operator interface slots All should be finger tight initially Step 3 Torque all fasteners to 6 17lb inch 0 7N M Over torque may cause damage to the operator interface housing Step 4 Maintain a minimum spacing of 60mm from the back of the operator interface ventilation holes fastener 16 16 3 20 4 Units mm Units mm EATON CORPORATION www eato...

Page 5: ...e to vibration and varying temperatures Ensure that oil water metallic particles or any foreign objects do not fall inside the operator interface ventilation slots and holes as this may cause damage to the unit Ensure the enclosure is free from harmful dust gases and liquids Inspection before system operation power not applied Ensure that all wiring terminals are correctly insulated Visually check...

Page 6: ...t support RS 422 flow control function HMIVU08CUNBE HMIVU10WCUNBE COM1 Port Supports Flow Control Contact PIN RS 232 1 2 RXD 3 TXD 4 5 GND 6 7 RTS 8 CTS 9 Note Blank No Connection COM2 Port Supports Flow Control MODE1 MODE2 MODE3 PIN RS 232 RS 422 RS 485 1 TXD D 2 RXD 3 TXD 4 RXD 5 GND GND GND 6 TXD D 7 RTS 8 CTS 9 RXD Note1 Blank No Connection Note2 When COM2 port is used for RS 232 flow control ...

Page 7: ...XD 3 TXD 4 RXD CTS 5 GND GND GND 6 TXD RTS D 7 8 9 RXD CTS Note1 Blank No Connection Note2 When COM2 port is used for RS 422 with flow control COM3 Port pins 1 4 6 and 9 are used for the signals RTS CTS RTS and CTS as shown in brackets Ethernet Port Contact Ethernet Port PIN Ethernet 1 TX 2 TX 3 RX 4 5 6 RX 7 8 Note Blank No Connection ...

Page 8: ...HMi VU Series Instruction Leaflet Hardware Features HMIVU06CUNB Front View A B A Power LED Indicator Lights in green when power is applied B Touch Screen Display EATON CORPORATION www eaton com 7 ...

Page 9: ...w C G B F A E D A Power Input Terminal E USB Host B COM2 and COM3 Note1 F USB Slave C COM1 G System Button D Battery Cover NOTE 1 Refer to the Pin Definition for Communications section for simultaneous use of COM2 and COM3 EATON CORPORATION www eaton com 8 ...

Page 10: ...HMi VU Series Instruction Leaflet HMIVU07CUNBE Front View A B A Power LED Indicator Lights in green when power is applied B Touch Screen Display EATON CORPORATION www eaton com 9 ...

Page 11: ...nput Terminal F USB Host B COM2 and COM3 Note1 G USB Slave C COM1 H System Button D Battery Cover I Ethernet Port E Memory Card Slot J Audio Output Port NOTE 1 Refer to the Pin Definition for Communications section for simultaneous use of COM2 and COM3 EATON CORPORATION www eaton com 10 ...

Page 12: ...ED Indicator Blue Note1 The operation LED indicator blinks in blue when communicating or accessing data C Alarm LED Indicator Red The alarm LED indicator blinks in red when one of the alarms is on D Touch Screen Display NOTE 1 The function for which the Blue LED indicator lights can be selected in HMiSoft EATON CORPORATION www eaton com 11 ...

Page 13: ...inal B COM3 Two LED indicate Read or Write status during the communication process C COM2 Two LED indicate Read or Write status during the communication process D COM1 E USB Slave F Ethernet Port G USB Host H Audio Output Port I Memory Card Slot Battery Cover EATON CORPORATION www eaton com 12 ...

Page 14: ...icator Blue Note1 The operation LED indicator blinks in blue when communicating or accessing data C Alarm LED Indicator Red The alarm LED indicator blinks in red when one of the alarms is on D Touch Screen Display A B C NOTE 1 The function for which the Blue LED indicator lights can be selected in HMiSoft EATON CORPORATION www eaton com 13 ...

Page 15: ... COM2 Two LED indicate Read or Write status during the communication process C COM3 Two LED indicate Read or Write status during the communication process D COM1 E USB Slave F Ethernet Port G Memory Card Slot Battery Cover H USB Host I Audio Output Port J System Button EATON CORPORATION www eaton com 14 ...

Page 16: ...struction Leaflet Panel Cut Out HMIVU06CUNB 6 79 172 4 7 24 184 5 67 144 0 063 1 6 0 24 6 5 21 132 4 HMIVU07CUNBE 7 24 184 5 67 144 5 21 132 4 6 79 172 4 0 063 1 6 0 24 6 HMIVU08CUNBE EATON CORPORATION www eaton com 15 ...

Page 17: ...HMi VU Series Instruction Leaflet 0 063 1 6 0 24 6 8 94 227 1 6 85 174 1 8 64 219 4 6 56 166 5 HMIVU10WCUNBE 10 71 272 7 88 200 0 063 1 6 0 24 6 10 29 261 3 7 45 189 3 EATON CORPORATION www eaton com 16 ...

Page 18: ...ler NOR Flash ROM Flash ROM 8 MB OS System 2MB User Application 6MB Flash ROM 128 MB OS System 30MB Backup 16MB User Application 82MB SDRAM 16Mbytes 64Mbytes Backup Memory 128Kbytes 16Mbytes Buzzer Multi Tone Frequency 2K 4K Hz 85dB Sound Effect Output AUX N A Stereo output Ethernet Interface N A IEEE 802 3 IEEE 802 3u 10 100 Mbps auto sensing has built in isolated power circuit Note 3 Memory Card...

Page 19: ... 1 75mm occasional 3 5mm 9Hz f 150Hz continuous 0 5g occa onal 1 0g si X Y Z directions for 10 times Dimensions W x H x D mm 184 x 144 x 50 184 x 144 x 50 227 1 x 174 1 x 61 272 x 200 x 61 Panel Cutout W x H mm 172 4 x 132 4 172 4 x 132 4 219 4 x 166 5 261 3 x 189 3 Weight Approx 670g Approx 800g Approx 1228g Approx 1520g NOTE 1 The half life of backlight is defined as original luminance being red...

Page 20: ......