background image

Questions?/ Des questions?/ ¿Preguntas? 1-800-334-6871 [email protected]

1

Instruction Manual / Manuel d’instructions/ Instrucciones

PACKAGING CONTENTS /CONTENU DE L’EMBALLAGE/CONTENIDO DEL PAQUETE

1.

  Turn off the power at the main fuse/breaker box.

2.

   Using the pattern on the box, mark and drill holes for mounting. 

NOTE:

 Mount this fixture in an upright and level position.

3.

   Install the two bottom mounting screws (C) first, leaving enough room between the 

mounting screws and the mounting surface to accommodate mounting the fixture.

4.

   Screw the top mounting screw (C) into the predrilled hole and back the screw out. This 

will leave the hole threaded and make installation of the fixture easier.

5.

   Remove lens by loosening the two screws inside the lens. Do not remove the screws.

6.

   Remove access cover (B) from fixture (A). Install 

the first conduit connector and conduit (sold  

separately) into the access cover (B) (Fig. 1).

7.

   Feed supply wires into conduit. Attach ground wire 

that is attached to fixture housing (A) to the junction 

box earth ground wire.

8.

  Connect the black fixture wire to the black supply 

wire (hot) with UL-approved wire connector (E). 

Connect the white fixture wire to the white supply 

wire (neutral) with UL-approved wire connector (E).

NOTE:

 Be careful to connect the wires correctly. 

Make sure no bare strands of wire extend from the 

wire nut or other approved wire connectors (E).

9.

   Attach access cover (B) to the light fixture (A)

using the two access cover mounting screws 

provided (F) (Fig. 1).

NOTE:

 Make sure all wiring is placed into the arm prior to tightening the access  

cover screws.

10.

 Place the fixture (A) on the two lower mounting screws (C) and install the upper mounting 

screw (C). Tighten all mounting screws to secure the fixture (A).

11.

 Reinstall the lens, making sure to tighten the two screws to secure the lens to 

the fixture (A).

12.

 Connect second conduit and conduit connector at the junction box (Fig. 1).

NOTE:

 This fixture can be mounted on 1-5/8 in. diameter extension arms (sold separately). 

When installing fixture onto an extension arm, remove the access cover (B) and use the 

included pole mounting clamp (D) and access cover mounting screws (F).

13.

 Turn power back ON

ITEMS REQUIRED

 

(Purchase separately)

•  Phillips screwdriver
•  Adjustable wrench or ratchet wrench with 10mm socket
•  Drill with 3/16 in. drill bit
•  1/2 in. diameter conduit (if applicable, length depends on application)
•  1/2 in. watertight conduit connectors (if applicable)
•  Wire connectors

IMPORTANT SAFETY INSTRUCTIONS

  When using product, basic precautions should always be followed, including the following:

•  Heed all warnings, including below warnings AND those included on product.
•  Save these instructions and warnings.
•  For outdoor use only.
•  cULus LISTED for wet location use.

•  Read and follow these instructions.
•  Disconnect at fuse or circuit breaker before installing or servicing.
•  Edges may cut. Handle with care.

CAUTION

•  Connect fixture to a 120 volt, 60 Hz power source. Any other connection voids 

the warranty.

•  Fixture should be installed by persons with experience in household wiring or by a 

qualified electrician. The electrical system, and the method of electrically connecting 

the fixture to it, must be in accordance with the National Electrical Code and local 

building codes.

•  Upside down installation can result in overheating or accumulation of water in fixture.

Install right side up.

•  This device complies with Part 15 of the FCC Rules. Operation is subject to the  

following two conditions: (1) This device may not cause harmful interference, and (2) 

this device must accept any interference received, including interference that may cause 

undesired operation   
     

WARNING: FCC Regulations state that any unauthorized changes or  

modifications to this equipment not expressly approved by the manufacturer 

could void the user’s authorization to operate this equipment.

SAVE THESE INSTRUCTIONS.

MOUNTING AND WIRING YOUR FIXTURE

NOTE:

 This fixture is intended to be conduit connected to a properly installed and properly 

grounded metal weatherproof junction box (not included). All conduit connectors, conduit, and 
junction boxes (sold separately) should be cULus Listed suitable for wet locations.

 ENGLISH

WARNING

A.

  Light fixture

  Appareil d’éclairage

  Accesorio

B.  Access cover
  Cache d’accès 
  Cubierta de acceso

C.  (3) Mounting screws
  (3) Vis de montage 
  (3) Tornillos de montaje

D.

  Pole mounting clamp

  Patte pour montage 

sur bras

 Abrazadera para 

montaje de poste

E.  (3) Wire connectors
  (3) Capuchons de connexion 
  (3) Conectores de cables

F.  (2) Access cover mounting screws
  (2) Vis de montage du cache d’accès 
  (2) Tornillos de la cubierta de acceso 

1

Conduit

Conduit

connector

Junction 

box

A

B

AL1550LPCBZ

AL1550LPCH

AL3050LPCBZ

AL3050LPCBZH

AL3250LPCIBZ

AL3250LPCIBZH 

AL5550LPCIBZ

AL5550LPCIBZH

(Bronze/Bronze/Bronce)

 

AL1550LPCGY

AL3050LPCGY

AL3250LPCIGY 

AL5550LPCIGY 

(Gray/Gris/Gris)

 

Problem

Cause

Solution

Light does not 
come on or  
light comes  
on for only a 
few seconds.

No power to the fixture.

•  Check if circuit breaker tripped.
•  Confirm wall switch is ON.

Light sensor is not 

working properly.

•  Check if light is being reflected into the 

    sensor, causing the fixture to turn off.

Wiring to the unit 

is loose.

TURN OFF POWER BEFORE CONTINUING.

•  Confirm wiring is properly secured.

TROUBLESHOOTING

Reviews: