127
Front Section Disassembly
4
FSO-2405
2nd Ed. 02/07
Front Section
FSO-2405/46
FSO-2405/45
1
2
Expansive Plugs
Some through holes in housings are drilled for
machining purpose only and must be blocked later
by using expansive metallic plugs.
During the transmission life, it is possible to
happens that those plugs should be removed and
reinstalled when servicing the unit.
Removal
1. In the housing, locate the plug that should be
removed. Use the special device and make a
thread in the plug.
NOTE: See “Special Tools”, Ref. E005005.
2. Use one retaining capscrew removed from the
housing and insert it into the plug, threading it
until it stays firmly in place.
3. Use an impact puller to remove the capscrew
and the plug comes along.
NOTE: See “Special Tools”, Ref. E003001,
E004002
FSO-2405/169
3
Summary of Contents for Fuller FSO-2405
Page 1: ...Eaton Fuller Light Duty Transmissions 2nd Ed 02 07 FSO 2405 Service Manual Transmission...
Page 2: ......
Page 4: ......
Page 9: ...9 General Table of Contents FSO 2405 2ndEd 02 07...
Page 10: ......
Page 12: ......
Page 78: ...78 Installation Reference 1 General Information 2nd Ed 02 07 FSO 2405 VM Motori VM Motori 01...
Page 79: ...79 Installation Reference 1 FSO 2405 2nd Ed 02 07 General Information VM Motori VM Motori 02...
Page 84: ......
Page 86: ......
Page 90: ......
Page 110: ......
Page 114: ......
Page 156: ......
Page 158: ......