background image

11

EATON    

 IB528001EN

    

 Installation instructions

Installation Instructions - Arena Series

WARNING

NEVER use any power tools on the Luminaire while the power is on. The vibration caused by power tools may 

damage the Luminaire. FAILURE TO FOLLOW THIS WARNING MAY LEAD TO LUMINAIRE INTERNAL DAMAGE AND 

FAILURE.

otee:

N

For outdoor daytime aiming when the laser dot is difficult to see, a piece of rigid tubing may be used in place of the 

laser. Outside diameter of tube must be 0.8”-0.87” (ANSI NPS ½”) to fit into the Aiming Mount. Slightly smaller 

conduit such as ½” EMT may be used in the mount with a grommet or other shim only if the shim is evenly 

distributed around the tubing to keep it correctly aligned perpendicular to the front face plates of the luminaire.

WARNING

NEVER point the aiming laser at any person or animal as it can cause permanent damage to eyes. Use laser only for 

aiming Luminaires as directed. FAILURE TO FOLLOW THIS WARNING MAY LEAD TO SEVERE INJURY.

otee:

N

Turn off laser while not in use to conserve battery life. Have a spare battery charged to facilitate the aiming process.

Laser Aiming Instructions

Equipment Required:

Tape Measures or Digital Range Finder

Paper Plates

Spare batteries for Laser or charger if needed

Laser or Aiming Tube

Aiming Mount

1 5/16” Socket Wrench or impact driver (For hex nuts on center stud mounts, Orient aiming)

3/8” Hex driver (For allen bolt, Tilt aiming)

Torque wrench/driver

PROCEDURE:

1.  Slide the laser into the Mount, with the on/off button at the top and the laser end directed out toward the end with the 

U-shaped flange. The laser does not need to fit all the way in – it’s designed to interfere as it is pressed in, about halfway 

down is sufficient.

otee:

N

It may be necessary to file off the knurled section of the laser if it doesn’t fit properly in the Mount, as shown. This 

can be done with a metal file and won’t damage the laser.

2.  For each light, insert the Mount into the back of the light Luminaire between the two heat sinks near the center, as 

shown on the right. If necessary, gently rock the Mount back and forth until it fully seats into place.

 

Position the Mount to either side of the gap in the fins, this will allow the fins to help hold the mount in place. If the fit 

is too tight, do not force the Mount to snap in – just press in gently and align it perpendicular to the face of the light. If 

the fit is too loose and the Mount wobbles, hold it in place during aiming by pressing down. This will hold it flat against 

the fins and ensure alignment.

Summary of Contents for ephesus Arena Series

Page 1: ...work FAILURE TO FOLLOW THIS WARNING MAY LEAD TO DEATH SEVERE INJURY OR PROPERTY DAMAGE DO NOT make or alter any open holes in the luminaire Do not modify the luminaire WARNING Follow all applicable s...

Page 2: ...rque wrench rated to a minimum of 35 ft lbs Step 4 Aim the Luminaire Torque driver with 3 8 hex bit rated to a minimum of 35 in lbs Step 4 Aim the Luminaire Calibrated light meter Step 4 Aim the Lumin...

Page 3: ...otify Ephesus before proceeding with installation Figure 1 Acceptable Power Configurations WARNING Follow proper grounding methods Electrical system must be grounded If you are not sure if your power...

Page 4: ...LEAD TO DEATH SEVERE INJURY OR PROPERTY DAMAGE Equipment Required Mounting Hardware Socket wrenches and or crescent wrenches sized to fit mounting hardware Cable ties or wire management restraints For...

Page 5: ...ost rail in the catwalk structure a Ensure the back set screw is secure to the railing The set screw must make contact with the catwalk railing prior to tightening the nut to prevent loosening Tighten...

Page 6: ...k or pendant Apply thread locking compound to all threaded connections to prevent loosening b If attaching to the 5 16 18 threaded stud torque all hardware connections to minimum of 10 ft lbs Apply th...

Page 7: ...with the Luminaire FAILURE TO FOLLOW THIS WARNING MAY LEAD TO DEATH SEVERE INJURY OR PROPERTY DAMAGE Electrical Power Control Connections Wiring connections Connect the incoming power wires to the Lu...

Page 8: ...receiving the signal may result in transient or fluttering control signals which can cause damage to the luminaire FAILURE TO FOLLOW THIS WARNING MAY LEAD TO LUMINAIRE INTERNAL DAMAGE AND FAILURE Con...

Page 9: ...of the LED lighting solution to ensure that light is evenly distributed on the playing surface There are two basic methods to properly aim a sports venue Precision Laser Aiming by Coordinates and Ori...

Page 10: ...e offset by the mounting bracket arm Figure 8 Tilt 90 270 0 180 Tilt Angle Figure 7 Orient 180 270 90 0 Orient is a vector in the Z plane looking down on the luminare from above ORIENT Orient Angle Ti...

Page 11: ...Digital Range Finder Paper Plates Spare batteries for Laser or charger if needed Laser or Aiming Tube Aiming Mount 1 5 16 Socket Wrench or impact driver For hex nuts on center stud mounts Orient aimin...

Page 12: ...cket connects to the LED modules c Retighten all hardware after the Luminaire is aimed to the correct point Note N Luminaire may shift while tightening After tightening Luminaire bolts briefly turn la...

Page 13: ...ted foot candle readings are taken at 3 above ground holding the meter out at arm s length as much as possible thereby reducing the effect of the shadow from your body Note N Take horizontal readings...

Page 14: ...ver time depending on the environmental conditions at the installation site Proper care of the luminaires will maintain their performance and appearance Follow a regular maintenance schedule to retain...

Page 15: ...15 EATON IB528001EN Installation instructions Installation Instructions Arena Series...

Page 16: ...odas las marcas comerciales son propiedad de sus respectivos propietarios Product availability specifications and compliances are subject to change without notice La disponibilit du produit les sp cif...

Reviews: