Changing the value in “Service
Data Objects”
31
09/08 AWB2724-1614en
Changing the value in
“Service Data Objects”
X
To use analog inputs of the expansion unit, select the
“Service Data Objects” tab and set “Analogue input
global interrupt enable” to “1”. Otherwise no values are
transmitted for analog inputs!
You have now made all required settings. The following
section contains information about the CAN input and
output addresses.
Input and output
addresses
Depending on your hardware combination (i.e. with or
without expansion unit and digital or analog inputs and
outputs) various CAN input and output addresses must be
observed.
EC4E-card without expansion unit (EC4E-221-
6D4X.eds)
EDS file EC4E-221-6D4X.eds is used for the EC4E module
without expansion unit.
Figure 18: Input and output addresses for the EC4E module
without expansion unit