The safety gate function block is used for the safety-related
monitoring of safety gates. These gates are required to
prevent persons from entering a hazardous area. For this a
1-channel or 2-channel switch monitors the position of the
gate as well as the guard if required.
easySafety allows the monitoring of up to fourteen 1-
channel safety gate circuits or seven 2-channel safety gate
circuits.
Function block
Figure 239:
Function block: "Safety gate"
a
Coils SG..I1 to SG..I3: connection of the monitoring switches:
– I1 and I2: Gate switch channel 1 and 2
– I3: Guard locking
Use only in the safety circuit diagram.
b
Coil SG..RE: Reset of the function block in the Manual Start
(MST) and Controlled Start (CST) modes and the starting of
normal operation.
Use only in the safety circuit diagram.
I1
I2
RE
EN
>DT
QS
ER
DG:
QV:
SG...
Safety Gate
a
b
c
d
e
f
g
h
I3
DW