Read image data
65
09/10 MN05013007Z-EN
Analog inputs: I7 – I8
The values of both analog inputs I7, I8 (only EASY...-DC-..)
are read with the following command.
Analog inputs I7 and I8 (byte 1 and byte 2)
These two bytes contain the process variable of the analog
inputs I7 and I8. Their value lies between 00 and 99, which
is equivalent to a voltage level of 0 to 9.9 V at the inputs. The
corresponding values are returned in hexadecimal format.
Example:
Byte
Meaning
Value (hex), sent by
Bit
M
S
Master
Slave
7 6 5 4 3 2 1 0
Attribute ID
Read
5B
–
0 1 0 1 1 0 1 1
0
Response
Read successful
–
C2
1 1 0 0 0 0 1 0
Command
rejected
–
C0
1 1 0 0 0 0 0 0
0
1
Analog value of I7
00
See below
1
2
Analog value of I8
00
M
= master
S
= Slave
Byte
Valu
e
Description
0
42
hex
The read request has been executed. Data
follow.
1
20
hex
Voltage level at input I7 = 3.2 V
2
31
hex
Voltage level at input I8 = 4.9 V