background image

04

/2

1

IL

04

005

9Z

U

10/12

DC1-…-A66…

DC1-…-A6S…

1410 min

230/400 V

3.2/1.9 A

50 Hz

-1

0.75 kW

cosϕ 0.79

P-07

P-08

P-10

P-09

> 1 s

4 x

= 1.9 A

> 1 s

P-08

P-01
P-08

Stop

Stop

A

2.3

A

1.9

START

STOP

Speed/Frequency

Stop

RUN

Reverse

Speed Reference

f

min -

f

max

P-02 - P-01

(0 - 50 Hz)

RUN

Forward

Mains switch

1

Enable

(Example)

Herz

Ampere

Herz

2

or

1

2

STOP

Motor

> 1 s

1 x

> 1 s

n x

START

Motor

Motor Start FWD

STOP

(Example)

or

STOP

Motor

n x

Motor Start FWD

Ampere

Herz

STOP

n x

Motor Start REV

Herz

0

Summary of Contents for DC1-1D-A6 OE1 Series

Page 1: ...te Vain p tev t s hk asentajat ja opastusta saaneet henkil t saavat suorittaa seuraavat ty t Nebezpe razu elektrick m proudem N e uveden pr ce sm j prov d t pouze osoby s elektrotechnick m vzd l n m E...

Page 2: ...87 3 5 0 14 4 2 0 16 8 5 0 33 7 kg 15 43 lbs FS4 DC1 32 DC1 34 240 9 45 227 8 94 360 14 17 300 11 81 33 4 1 31 271 2 10 68 262 1 10 32 3 5 0 14 4 2 0 16 8 5 0 33 9 5 kg 20 94 lbs DC1 A66 66 IP66 DC1...

Page 3: ...G 21 2 x M32 FS4 2 x 37 1 46 2 x PG 29 2 x M40 c b a a c 4 x M4 1 Nm 8 85 lb in FS1 FS2 FS3 FS4 30 30 30 30 a b c 10 mm 0 39 10 mm 0 39 200 mm 7 87 1 3 4 1 2 PZ 2 2a 2b 3a 1 2 3 4 5 6 7 8 9 10 IOIOI I...

Page 4: ...U2 V2 ULN 400 V U1 V1 W1 W2 U2 V2 U1 V1 W1 W2 U2 V2 M FWD M REV 100 mm 3 94 Power L1 L2 L3 N PE U V W DC BR Control 1 2 11 Modbus CANopen 1410 min 230 400 V 3 2 1 9 A 50 Hz 1 0 75 KW cos 0 79 DC1 1 2...

Page 5: ...ujte samo u beznaponskom stanju FIGYELEM Csak fesz lts gmentes llapotban csatlakoztassa B LD R M Sadece gerilim s f rken ba lay n OPGELET Alleen in spanningsloze toestand aansluiten UZMAN BU Piesl gt...

Page 6: ...0 DC1 32011 OE1 FS2 2 2 3 12 1 16 17 5 0 75 18 8 8 10 5 50 DC1 32018 OE1 FS3 4 5 20 9 32 0 75 18 8 8 18 25 DC1 32024 OE1 FS3 5 5 7 5 26 4 40 35 0 75 18 8 8 24 20 DC1 32030 OE1 FS4 7 5 10 33 3 40 45 1...

Page 7: ...UN I 10 11 f Fix1 M FWD Resistance 1 10 k AC DC AC Varistor DC Diode AC RC lter 20 m 65 62 ft PES M REV 1 2 3 4 5 6 7 8 9 10 11 1 2 3 4 5 6 7 8 9 10 11 24 V DI1 AI1 0 V DI2 DI3 AO1 0 V K13 K14 10 V 1...

Page 8: ...AC 460 V PES L1 L L3 L2 N 3 AC 200 V 240 V 10 3 AC 380 V 480 V 10 50 60 Hz W V U M 3 L1 L2 L3 Q1 I I I EMC DC1 32 A66 DC1 34 A66 1 2 3 4 5 6 7 8 9 10 IOIOI IOIOI U V W L1 L L2 N L3 EMC EMC L3 L2 N L1...

Page 9: ...230 V 3 AC 400 V 3 AC 460 V PES L1 L L3 L2 N 3 AC 200 V 240 V 10 3 AC 380 V 480 V 10 50 60 Hz W V U M 3 L1 L2 L3 Q1 I I I PWR EMC DC1 32 A6S DC1 34 A6S 1 2 3 4 5 6 7 8 9 10 IOIOI IOIOI U V W L1 L L2...

Page 10: ...P 01 P 08 Stop Stop A 2 3 A 1 9 START STOP Speed Frequency Stop RUN Reverse Speed Reference fmin fmax P 02 P 01 0 50 Hz RUN Forward Mains switch 1 Enable Example Herz Ampere Herz 2 or 1 2 STOP Motor...

Page 11: ...o czy z przewodem uziemiaj cym na wi kszej powierzchni 2006 42 EG PE PREVIDNO Na obmo ju veljavnosti direktiv ES je zagon frekven no krmiljenih naprav in njihovega pribora dovoljen le tedaj ko je bilo...

Page 12: ...on allowed 115 Volt RMS Maximum DC1 x2 200 240 RMS Volts for 230 Volt rated units 10 variation allowed 240 Volt RMS Maximum DC1 34 380 480 Volts for 400 Volt rated units 10 variation allowed Maximum 5...

Reviews: