background image

9

Installation manual 10679

Effective October 2017

BSPA Type 1 and Type 2 surge protective devices

Eaton.com/bussmannseries

13. Voltage configurations per enclosure size

P1 enclosure

P2 enclosure

120N/240N

50 – 200 kA

600D

50 – 200 kA

240S

50 – 100 kA

240S

120 – 200 kA

208Y/415Y/ 

480Y/600Y

208Y/415Y/ 

480Y/600Y

240D/480D

240D/480D

14. Warranty

The BSPA is warranted to be free from defects in both workmanship 

and materials for a period of ten years from the date of delivery to 

the purchaser.
The Bussmann Division assumes no risk or liability for results of 

the use of the product purchased, including but not limiting the 

generality of the foregoing:
(1) The use in combination with any electrical or electronic 

components, circuits, systems, assemblies or any other materials 

or substances.

(2) Unsuitability of any product for use in any circuit or assembly.
Purchaser’s rights under the warranty shall consist solely of 

requiring the Bussmann Division to repair, or at the Bussmann 

Division’s sole discretion, replace, free of charge, F.O.B. factory, 

any defective items received at said factory within said term 

determined by the Bussmann Division to be defective. The giving of 

or failure to give any advice or recommendations by the Bussmann 

Division shall not constitute any warranty by or impose any liability 

upon the Bussmann Division AND IS IN LIEU OF ANY AND ALL 

OTHER WARRANTIES EXPRESSED, IMPLIED OR STATUTORY 

AS TO THE MERCHANTABILITY, FITNESS FOR PURPOSE SOLD, 

PRODUCTIVENESS OR ANY OTHER MATTER. In no event shall the 

Bussmann Division be liable for special or consequential damages or 

for delay in performance of the warranty.
This warranty does not apply if the unit has been misused, abused, 

altered, tampered with, or applied in excess of the specifications 

other than those written on the nameplate. At the end of the 

warranty period the Bussmann Division shall be under no further 

warranty obligation expressed or implied.
The Bussmann series BSPA covered by this warranty certificate can 

only be repaired or replaced by the factory. A RETURN MATERIAL 

AUTHORIZATION (RMA) number must be obtained. Please 

enter a Vista warranty claim by contacting your local authorized 

Bussmann series product distributor or sales representative for 

help entering a claim or to obtain an update on your claim status. 

Repair or replacement will be returned collect. If it is determined 

that the returned product contains manufacturer’s defects then 

the Bussmann Division will replace the defective product at the 

Bussmann Division’s expense (including shipping charge).

Summary of Contents for BUSSMAN Series

Page 1: ...MOV while supporting power frequency voltage The Type 2 BSPA models equipped with EMI filtering are designed to protect sensitive equipment from electrical noise Proper installation is critical to ensure the BSPA unit operates as intended The Type 1 BSPA units are intended for installation between the secondary of the service transformer and the lineside of the service equipment overcurrent protec...

Page 2: ... accordance with established safety practices d is trained to render first aid e has received safety training to recognize and avoid the hazards involved f has the skills and knowledge pertaining to the construction and operation of this equipment and its installation IMPORTANT These procedures do not claim to cover all possible details or variations encountered with the installation of a Surge Pr...

Page 3: ...identifies the unit s specifications and permits specifying any combination to meet requirements BSPA 200 208Y 8 P BSPA Product family Surge rating per phase Voltage system code Options NEMA enclosure For example BSPA unit catalog number BSPA200208Y8P where BSPA BSPA series 200 peak surge current rating 50 kA 200 kA 208Y voltage code and system configuration 8 feature option 1 8 P enclosure type N...

Page 4: ...S POSSIBLE SEE FIGURE 3 6 2 Panel mounted The preferred mounting of the BSPA is directly to the electrical panel with its integrated male connector hub and the supplied 3 4 trade size conduit locknut Insert the wires through the panel wall being careful not to damage the wire insulation Install the provided locknut and tighten to 20 3 lb in 2 3 N m If the installation requires the NEMA 4X rating i...

Page 5: ...ncluded 3 4 14 NPS external thread Locknut Mounting feet included 36 inch long wires 3 75 95 3 2 38 60 4 8 48 215 4 10 25 260 4 11 50 292 1 7 48 190 0 9 25 235 0 10 50 266 7 4X Ø 0 223 0 80 20 3 6 67 169 4 0 0747 THK 1 51 38 4 1 51 38 4 6 4 Enclosure mounting feet and dimensions The mounting feet attach to the bottom of the enclosure with the provided screws hardware to mount the feet to wall are ...

Page 6: ...C typically requiring a 1 pole for single phase systems 2 pole for split phase systems or 3 pole for 3 phase systems 30 A branch circuit breaker to protect BSPA conductors Twist and bind the wires of the BSPA unit tightly together To optimize BSPA performance minimize overall lead length To maximize performance for wire lengths longer than four inches phase wires should be twisted once for each fo...

Page 7: ... product distributor or Bussmann series product representative as the SPD may be damaged 8 3 Options audible alarm and Form C relay Note Using Form C contacts is optional Connection is not required for the proper BSPA operation The audible alarm and Form C relay are tied to the phase LEDs on the BSPA enclosure If protection to one or more phases is lost the following will occur Single split and 3 ...

Page 8: ...utlined in appropriate Bussmann Division selling policies or other contractual agreements between the parties This manual is not intended to and does not enlarge or add to any such contract The sole source governing the rights and remedies of any purchaser of this equipment is the contract between the purchaser and the Bussmann Division NO WARRANTIES EXPRESSED OR IMPLIED INCLUDING WARRANTIES OF FI...

Page 9: ...re to give any advice or recommendations by the Bussmann Division shall not constitute any warranty by or impose any liability upon the Bussmann Division AND IS IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESSED IMPLIED OR STATUTORY AS TO THE MERCHANTABILITY FITNESS FOR PURPOSE SOLD PRODUCTIVENESS OR ANY OTHER MATTER In no event shall the Bussmann Division be liable for special or consequential dam...

Page 10: ...t of Eaton CSA is a registered trademark of the Canadian Standards Group NEC is a registered trademark of the National Fire Protection Association UL is a registered trademark of the Underwriters Laboratories Inc Eaton 1000 Eaton Boulevard Cleveland OH 44122 Eaton com Bussmann Division 114 Old State Road Ellisville MO 63021 United States Eaton com bussmannseries 2017 Eaton All Rights Reserved Prin...

Reviews: