background image

P50796

 Rev 07

P50796

 Rev 07

Effective: June 2010

Effective: June 2010

INSTRUCTION MANUAL:

ENHANCED 50 SERIES PHOTOELECTRIC SENSORS

THRU-BEAM

MODELS COVERED IN THIS MANUAL

AC/DC Models

Style

Output Type

6-Foot Cable

Integral Micro Quick 
Disconnect

Integral Mini Quick Disconnect

Pigtail Micro 
Quick Disconnect

No Time 
Delay

With Time 
Delay

No Time 
Delay

With Time 
Delay

No Time 
Delay

With Time 
Delay

No Time 
Delay

With Time 
Delay

200-Foot Thru-Beam 
Source (Emitter)

N/A

1150E-6513

N/A

1150E-6543

N/A

1150E-6504

N/A

1150E-6534

N/A

200-Foot Thru-Beam 
Detector (Receiver)

Solid-State Relay

1250E-6513

1250E-8513

1250E-6543*

1250E-8543*

1250E-6503

1250E-8503

1250E-6533

1250E-8533

Electromechanical 
Relay

1250E-6514

1250E-8514

N/A

N/A

1250E-6504

1250E-8504

1250E-6534

1250E-8534

500-Foot Thru-Beam 
Source (Emitter)

N/A

1151E-6513

N/A

1151E-6543

N/A

1151E-6504

N/A

1151E-6534

N/A

500-Foot Thru-Beam 
Detector (Receiver)

Solid-State Relay

1251E-6513

1251E-8513

1251E-6543*

1251E-8543*

1251E-6503

1251E-8503

1251E-6533

1251E-8533

Electromechanical 
Relay

1251E-6514

1251E-8514

N/A

N/A

1251E-6504

1251E-8504

1251E-6534

1251E-8534

DC Models

Style

Emitter LED

Output Type

6-Foot Cable

Integral Euro (Micro) Quick 
Disconnect

Integral Mini Quick Disconnect

Pigtail Euro (Micro) Quick 
Disconnect

No Time 
Delay

With Time 
Delay

No Time 
Delay

With Time 
Delay

No Time 
Delay

With Time 
Delay

No Time 
Delay

With Time 
Delay

200-Foot Thru-Beam 
Source (Emitter)

N/A

1150E-6517

N/A

1150E-6547

N/A

1150E-6507

N/A

1150E-6537

N/A

200-Foot Thru-Beam 
Detector (Receiver)

NPN/PNP

1250E-6517

1250E-8517

1250E-6547

1250E-8547

1250E-6507

1250E-8507

1250E-6537

1250E-8537

500-Foot Thru-Beam 
Source (Emitter)

N/A

1151E-6517

N/A

1151E-6547

N/A

1151E-6507

N/A

1151E-6537

N/A

500-Foot Thru-Beam 
Detector (Receiver)

NPN/PNP

1251E-6517

1251E-8517

1251E-6547

1251E-8547

1251E-6507

1251E-8507

1251E-6537

1251E-8537

* Versions of these sensors are available with a non-isolated output. Non-isolated output models end in -45, ex. 1350E-6545. For more information, consult wiring diagrams on Page 4.

WARNING

THESE PRODUCTS ARE NOT DESIGNED, TESTED, OR RECOMMENDED FOR 
USE IN HUMAN SAFETY APPLICATIONS.

DURING INSTALLATION, CORRECT POWER CONNECTIONS MUST BE 
MADE FIRST TO ENSURE FAIL-SAFE SHORT CIRCUIT PROTECTION OF THE 
OUTPUTS. REFER TO THE WIRING DIAGRAMS IN THIS MANUAL.

DO NOT USE TOOLS TO APPLY TORQUE DIRECTLY TO SENSOR BODY. 
ALIGN SENSOR BY HAND BEFORE TIGHTENING MOUNTING HARDWARE. 

ADJUSTMENT POTS ARE 3/4 TURN DEVICES. ANY RESISTANCE 
ENCOUNTERED WHILE ADJUSTING THESE POTS INDICATES YOU HAVE 
REACHED THE ADJUSTMENT LIMIT STOP. TURNING PAST THIS STOP 
WILL DAMAGE THE SENSOR.

USE ONLY THE ADJUSTMENT TOOL PROVIDED OR SUITABLE 
SCREWDRIVER WHEN TURNING ADJUSTMENT POTS OR SETTING SWITCH 
POSITIONS. SHARP OBJECTS CAN DAMAGE THE SENSOR AND RESULT IN 
ELECTRICAL SHOCK.

ENSURE THE PRODUCT IS CONNECTED TO THE CORRECT POWER SUPPLY 
FOR THE APPLICATION.  REFER TO THE WIRING DIAGRAMS IN THIS 
MANUAL.  

AC/DC CONNECTOR VERSION SENSORS ARE EQUIPPED WITH AN AC-
TYPE CONNECTOR. THE USE OF DC POWER WITH AC-TYPE CONNECTORS 
MAY NOT CONFORM WITH ESTABLISHED STANDARDS.

Page 1

Page 4

INTRODUCTION

Enhanced 50 Series photoelectric sensors offer fl exibility, durability, and 
high optical performance in a low-cost self-contained package.  Each 
sensor features several mounting options and a low-gain indicator for quick 
installation and easy alignment.  Models are available for operation with 
DC power, or AC and DC power in a single unit.  Sensors are wired using a 
6-foot power cable, body-mounted quick disconnect mini connector, body 
mounted quick disconnect micro (AC/DC Micro or Euro (Micro)) connector, or 
quick disconnect micro (AC/DC Micro or Euro (Micro)) connector on a short 
cable pigtail.  All sensors have built-in light/dark selection, and modes are 
available with timing features that include on-delay, off-delay, and one-shot 
delay.

An Enhanced 50 thru-beam photoelectric sensor installation consists of an 
emitter and a receiver positioned on opposite sides of a detection zone. The 
emitter emits infrared light, which is detected by the receiver. The receiver 
output switches on when this beam of light is either blocked (when set in 
dark operate mode) or completed (in light operate mode). 

A complete system consists of an emitter and receiver mounted such that 
the emitter directs its light beam at the receiver and the receiver is aimed 
to detect the beam. The emitter and receiver can be separated by up to 61 
meters (200 feet) using standard range models and 152 meters (500 feet) 
using extended range models. 

WIRING DIAGRAMS

 (Pin numbers are for reference only; rely on pin location when wiring)

Operating Voltage Models

Cable Models

Mini-Connector Models
(Face View Male Shown)

Micro-Connector Models
(Face View Male Shown)

10-40V DC

Thru-Beam Emitters

Thru-Beam Receivers

12-240V DC or
24-240V AC with
Solid-State Relay

Thru-Beam Emitters

Thru-Beam Receivers 
with Isolated AC/DC 
Output

Thru-Beam 
Receivers with 
Non-Isolated AC/DC 
Output

12-240V DC or
24-240V AC with
SPDT EM Relay

Thru-Beam Emitters

Thru-Beam Receivers

1

 Connect load to the appropriate outlet for either sinking or sourcing operation.

2

 Connecting the test input to 0V DC allows you to switch the light source off for troubleshooting while leaving the sensor under power.

3

 Over current protection is to be provided in the fi eld. Conductor size for 20 AWG: 5 amp; 22 AWG: 3 amp; 24 AWG: 2 amp.

BU

BR

BK

Test In

(+)

(–) OV

Test In

(–) OV

(+)

Test In

(–) OV

(+)

BU

WH NPN

PNP

(–) OV

BK

BN

(+)

Load

Load

(+)

(–) OV

PNP

NPN

Load

Load

(+)

(–) OV

PNP

NPN

Load

Load

BU

BR

L1 (+)

L2 (–)

L2 (–)

L1 (+)

L1 (+)

L2 (

)

BU

BK

WH

BR

L1 (+)

L2 (

)

Isolated
AC/DC Output

L2 (–)

L1 (+)

Isolated
AC/DC Output

L1 (+)

L2 (

)

Isolated

AC/DC

Output

L1 (

)

L2 (+)

Load

BU

BR

L1 (+)

L2 (–)

L2 (–)

L1 (+)

L1 (+)

L2 (

)

BU

OR

BK

BR

WH

N.C.

COM

N.O.

L2 (–)

L1 (+)

L1 (+)

COM

N.O.

N.C.

L2 (

)

L1 (+)

L2 (

)

COM

N.O. N.C.

Reviews: