Fault symptom

Reason

Remove method

c) The voltage became lower
d) The water level is too high or

less than the standard

e) There are oil in the water.

d) Adjust the water level
e) Clean the water tank and the

pipe

Off-odor exist in
the fog

There is foreign matter in the
tank or in the pipe

Remove the foreign matter inside

7. Maintenance

1. Water tank maintenance: Please replace the water in the water tank regularly to

reduce the deposition of scale in the atomizer.

2. Water tank cleaning: clean the water tank regularly. Turn off and uplog the

machine before cleaning so as to avoid contact incident.

3. Cleaning method: Turn the fixing screw on the cover of the water tank, and open

the tank cover plate(please pay attention to the circuit connection inside), use a
soft cotton close or brush to clean(Dish soap is available). see Fig 12. The scale
and other foreign matter around the water tank, then use clean water to flush out,
be careful not to spill water on the components and wiring to avoid short circuit.
(Don’t use high acid alkaline liquid cleaner to clean any parts of the atomizer.)

Remind:

We don’t recommend to add the water from the fog outlet or water

outlet, as the water level in the tank is difficult to be controlled by this way.

8. Precautions

1

The power supply must be grounded.

2

In principle, don’t add water from the outlet of fog , please connect the water
pipe to input water.

3

Direct humidification is not allowed, it is required that the pipe at the nozzle of

Summary of Contents for EW-08HS

Page 1: ...iguration and technical parameters 2 3 Filter installation and cleaning 3 4 Installation instruction 3 5 Atomization system 5 6 Regular failure and failure elimination 7 7 Maintenance 8 8 Precautions...

Page 2: ...e the water leaving the cover to create the water mist shape no need to heat or chemical to produce 1 to 5 mu water particles floating in the air thereby to improve the air quality and improve the env...

Page 3: ...or so to clean the filter element impurities or replacement Turn on the water filter bottle take out the filter element and wash it then put it back to the filter cover if the filter element with too...

Page 4: ...12m the spacing should be with 15 20cm Please also block off the end of the pipe so as to avoid water accumulation in the pipeline the level height of the ends should be adjustable slightly above the...

Page 5: ...components The worst result is cause accidents It is recommended that the equipment be separated from the humidifying room where the humidity is higher than 85 RH 5 Atomizing system The indicator lig...

Page 6: ...ion as following a Cut off the power drain the water from the tank and dry the water on the surface of the atomizer b Unscrew the pressure ring with the lock piece remove the old atomizer chip and kee...

Page 7: ...placed b There is foreign matter in the float c The float is damaged a Adjust it to the correct position b Remove the foreign matter c Replace the float No fog outlet a The voltage 5 lower than the st...

Page 8: ...g screw on the cover of the water tank and open the tank cover plate please pay attention to the circuit connection inside use a soft cotton close or brush to clean Dish soap is available see Fig 12 T...

Page 9: ...the water storage in the tank must be drained out entirely As if the storage water stocked too long time it will become ropy this will affect the function of the equipment 10 The overflow and drain pi...

Page 10: ...fter sales will give free maintenance The artificial damage and the damage caused by the irresistible force are not covered in the warranty We will charge a trend in the maintenance if the machine is...

Reviews: