background image

易仕韦尔

EASYWELL

5

Fig 8

Fig 9

Tips:

in the place where there is no need to install pipes, try not to fog along the front

of the machine (the direction of the control panel), fog to the left, right or behind of
the machine. Please ensure each outlet of the fog with a length of no less than 1 meter
pipe extension(you can also increase a 45℃ elbow). Under the condition of no
pipeline, it is not allowed to be used for a long time, otherwise the equipment will be
easily damaged by the dripping of fog droplets and the short cycle of moisture will
lead to the failure of components. The worst result is cause accidents. It is
recommended that the equipment be separated from the humidifying room where the
humidity is higher than 85%RH.

5. Atomizing system

The indicator light is green when powered up

and is red when working. The

indicator light is green when the water is not enough or water lever is not reached.

Requirements for water quality: when the water temperature of the tank is
≥45℃,the atomizer is forced to start protection, not to run; when there is oily or
sticky substances in the water, the atomizer does not work or fog; when the water
level exceeds the limit, the atomizer can not produce fog or spray column with a
small amount of fog.

The local water quality, environment, maintenance and other factors will directly

Summary of Contents for EW-05HS

Page 1: ...Configuration and technical parameters 2 3 Filter installation and cleaning 3 4 Installation instruction 3 5 Atomization system 5 6 Regular failure and failure elimination 7 7 Maintenance 8 8 Precautions 8 9 After sales service 9 Please read this carefully before using and keep it for reference Easywell Electronic Co Ltd ...

Page 2: ...ll make the water leaving the cover to create the water mist shape no need to heat or chemical to produce 1 to 5 mu water particles floating in the air thereby to improve the air quality and improve the environment 2 Configuration and technical parameters Model EW 05HS Mist capacity 5 L hour Control method Intelligent microcomputer automatic control Voltage Frequency AC220V 5 50 60Hz Power 300W Ma...

Page 3: ...months or so to clean the filter element impurities or replacement Turn on the water filter bottle take out the filter element and wash it then put it back to the filter cover if the filter element with too much impurities and dirty matter please replace it with new one Remark there is seal ring under the filter bottle please ensure it is in the original position The operation method of control pa...

Page 4: ...h is 12m the spacing should be with 15 20cm Please also block off the end of the pipe so as to avoid water accumulation in the pipeline the level height of the ends should be adjustable slightly above the mist side for the principle condensate can return In addition do not reduce the pipe diameter or make to much turning See Fig 7 When install the machine the pipe height should be higher than 1 me...

Page 5: ...e of components The worst result is cause accidents It is recommended that the equipment be separated from the humidifying room where the humidity is higher than 85 RH 5 Atomizing system The indicator light is green when powered up and is red when working The indicator light is green when the water is not enough or water lever is not reached Requirements for water quality when the water temperatur...

Page 6: ...Operation as following a Cut off the power drain the water from the tank and dry the water on the surface of the atomizer b Unscrew the pressure ring with the lock piece remove the old atomizer chip and keep the atomizer chamber clean c When install the new atomizer chip s front face up and reverse side back down Then tighten the pressure ring Special tips When the water level 0 1 0 5cm higher tha...

Page 7: ... displaced b There is foreign matter in the float c The float is damaged a Adjust it to the correct position b Remove the foreign matter c Replace the float No fog outlet a The voltage 5 lower than the standard b The water is too hard c Too dirty in the tank a Check the power or the current plate b Clean the water tank replace the clean water c Clean the tank Water exceed from the tank a Leaking f...

Page 8: ...ixing screw on the cover of the water tank and open the tank cover plate please pay attention to the circuit connection inside use a soft cotton close or brush to clean Dish soap is available see Fig 12 The scale and other foreign matter around the water tank then use clean water to flush out be careful not to spill water on the components and wiring to avoid short circuit Don t use high acid alka...

Page 9: ...and the water storage in the tank must be drained out entirely As if the storage water stocked too long time it will become ropy this will affect the function of the equipment 10 The overflow and drain pipes must be connected to the floor drain to avoid accident caused by leakage 9 After sales service 1 1 year warranty for the whole machine 2 Atomized ceramic wafers filter and fans are belong to t...

Page 10: ...ur after sales will give free maintenance The artificial damage and the damage caused by the irresistible force are not covered in the warranty We will charge a trend in the maintenance if the machine is not be operated correctly Please use clean water If the water is harder easy to produce white powder so should often change the softening resin Please clean the water tank 1 to 2 times a month wit...