Water pressure and water
temperature
Water pressure: 0.1-0.4MPa
Water temperature:1-35℃
Suitable water type
Clean water, Soft tap water
Devices equipped with
Water shortage protector, water pump, heating
plate.
3.
Installation instruction
Place the humidifier horizontally, fill the inner water bucket with solution liquid.
Sink the suction pipe of the pump into the bottom of the tank. Power on, the water
pump starts to absorb water, and the machine starts to work automatically when
the liquid reach to the operating water level.
When install the pipe, the pipe line must be arranged reasonably, the interface
must be sealed to prevent leakage of gas or water, please also make the pipe line
in leveled to ensure the fog pressure smoothly so as to avoid the machine damaged
by any blocking. In order to avoid the fog hole water beard down, the outlet hole
of the fog should be located in the position of the PVC pipe cross section level up
30 degrees or so. The best diameter of the out put fog hole is 20 to 30mm , the
spacing between the outlet hole of the fog is depends on the length of the pipe(for
example, if the single pipe length is 12m, the spacing should be with 15-20cm).
Please also block off the end of the pipe so as to avoid water accumulation in the
pipeline, the level height of the ends should be adjustable slightly above the mist
side for the principle, condensate can return.
In addition, do not reduce the pipe diameter or make to much turning. See Fig 7.