background image

SELF PRIMING EXTERNAL PUMPS

Reliability You Can Count On!

© 2021 EasyPro, Inc.

Pg. 1

 IN THE USA

ASSEMBLED

Installation and Service Manual

for EXP3200, EXP5000, EXP6800, EXP7800, EXP6000HP

WARNING: Please read completely before you install or operate your new pump! This is an external “out-of-pond” pump!

It is NOT submersible! Do NOT allow this pump to become submerged! Never run dry!

 

TYPE:  SELF PRIMING CENTRIFUGAL

 

MOTOR:  NEMA 56Y

 

HORSEPOWER:  1/2 (1750 RPM)  2 (3450 RPM)

 

MATERIAL:   GLASS-FILLED POLYPROPYLENE

 

HARDWARE:  STAINLESS STEEL HARDWARE

 

OPTIONS:  SALTWATER SERVICE

 

ACCESSORIES:  SWING CHECK VALVES (1

1

/

2

", 2", 3")

Please fill in for future reference: 

MODEL: _____________________________
SERIAL NUMBER: ____________________
DATE PURCHASED: __________________

* Please fill out the warranty registration 

card in this manual.

S/N: XXXX-XXXXXX

EXP3200

EasyPro

*Actual appearance 

may vary by model

Model 

EXP3200 EXP5000 EXP6800  EXP7800 

EXP6000HP

INLET 

2" 2" 2"  2" 2"

DISCHARGE 

2" 2" 2"  2" 2"

MAX FLOW (gph) 

3200 

5000 

6800 

7800 

6000

MAX HEAD (feet) 

15' 

18' 

19' 

24' 

60'

MAX POWER (watts) 

228 

310 

369 

504 

1416

MAX CURRENT (amps) 

2.68 @ 115v 

3.37 @ 115v 

3.93 @ 115v 

5.02 @ 115v 

8.7 @ 230v

VOLTS 

115/230 115/230 115/230  115/230 115/230

MOTOR 

HP 

1/2 1/2 1/2  1/2  2

MOTOR 

TYPE 

56Y 56Y 56Y  56Y 56Y

MOTOR 

ENCLOSURE TEFC TEFC TEFC  TEFC ODP

Summary of Contents for EXP3200

Page 1: ...SALTWATER SERVICE ACCESSORIES SWING CHECK VALVES 11 2 2 3 Please fill in for future reference MODEL ______________________________ SERIAL NUMBER _____________________ DATE PURCHASED ___________________ Please fill out the warranty registration card in this manual S N XXXX XXXXXX EXP3200 EasyPro Actual appearance may vary by model Model EXP3200 EXP5000 EXP6800 EXP7800 EXP6000HP INLET 2 2 2 2 2 DISC...

Page 2: ...DAMAGE THE MOTOR AND OR PUMP INSTALLATION Please read carefully When properly installed this primer pump will provide dependable trouble free service 1 Locate pump as near the source to be pumped as possible A flooded suction situation is preferred This pump is self priming however there must be fluid in the pump for it to function properly A check valve is recommended for non flooded suction Figu...

Page 3: ...g to bracket 12 Install drain plugs with its O rings in casing drain holes DISASSEMBLY 1 Shut off power to motor before disconnecting any electrical wiring 2 Close all necessary valves on inlet and discharge lines and drain the pump by removing both drain plugs The water will drain faster if you loosen the lid 3 Disassemble bracket motor assembly from casing by removing the nuts and bolts The casi...

Page 4: ...h is a registered trademark of Porter Manufacturing Noryl is a registered trademark of the General Electric Company Teflon is a registered trademark of DuPont Company Activate your warranty by filling out this form and mailing to EasyPro Pond Products 9182 9 21 EasyPro Pond Products Limited Warranty EasyPro Pond Products EasyPro warrants to the purchaser that this product Product will be free from...

Reviews: