Easy Controls MC231 User Manual Download Page 1

MC231 INPUT/OUTPUT BOARD

1

www.easy-controls.com

MC231 INPUT/OUTPUT BOARD

Features



On board opto-isolated RS485 interface.



5 dry contact inputs. (common ground)



All inputs have sensitivity setting for input noise rejection.



64 output drivers (Can be used to drive relays, LED

)



support Voltage Adjustable



Support

i-Control System



Support reprogram (

Easy Control

)



Provide ActiveX Control for your application software.

User

s Manual

DEVICE CODE: 231

Summary of Contents for MC231

Page 1: ...ace 5 dry contact inputs common ground All inputs have sensitivity setting for input noise rejection 64 output drivers Can be used to drive relays LED support Voltage Adjustable Support i Control Syst...

Page 2: ...ccur for any damage to property or persons resulting from improper use of this manual or from the related software NEWELL TECHNOLOGIES LIMITED products are not authorized for use as components in medi...

Page 3: ...ly J1 6 RESET 6 Communication Interface J2 JP2 JP3 JP4 6 Input Connection J3 7 Output Connection J4 J5 J6 J7 J8 J9 J10 J11 7 Device ID SW1 8 Easy Control Resource 9 Properties Settings 9 System variab...

Page 4: ...r Device ID System Startup Delay Jumper JP1 V OUT GND 32 31 30 29 28 27 26 25 V OUT GND 16 15 14 13 12 11 10 9 V OUT GND 48 47 46 45 44 43 42 41 V OUT GND 8 7 6 5 4 3 2 1 Output 1 48 Connector V OUT T...

Page 5: ...essed by device ID more than 256 addressed by serial number Inputs 5 dry contact Outputs 64 can be used to drive relay LED Communication Interface Separated RS485 Power supply 8 30 VDC Depending on th...

Page 6: ...interface The connector is J2 The communication baud rate can be software configured J2 Description 1 NC 2 Transport Receive TR 3 Transport Receive TR Communication Interface hardware settings There...

Page 7: ...Connection J4 J5 J6 J7 J8 J9 J10 J11 The device features 64 output drivers that can be used to drive relays LEDs and the single output maximum drive load current ratings is 350mA But the full load cu...

Page 8: ...11 0101 205 1011 0011 237 1011 0111 14 0111 0000 46 0111 0100 78 0111 0010 110 0111 0110 142 0111 0001 174 0111 0101 206 0111 0011 238 0111 0111 15 1111 0000 47 1111 0100 79 1111 0010 111 1111 0110 14...

Page 9: ...Resource to get the detail System Startup Delay Jumper JP1 Short the jumper system will delay five seconds to start if you have trouble to upload new program to the device after system start you can u...