background image

1

HART 475 COMMUNICATOR

USER MANUAL

Hangzhou Zhongchuang Electron Co., Ltd

Summary of Contents for HART 475

Page 1: ...1 HART 475 COMMUNICATOR USER MANUAL Hangzhou Zhongchuang Electron Co Ltd...

Page 2: ...vironment 4 Keyboard Introduction 4 Establish Connection 4 Funtion Introduction 6 Common Function Operation Example 9 Polling Meter Battery Power 12 Instrument Information 12 Language Selection 12 Res...

Page 3: ...ilt in 1 3 Dedicated test line 1 4 Charger 1 5 250 ohm resistor 2 6 User manual 1 Production Introduction HART series manual operators are suitable for the communication operation of HART protocol int...

Page 4: ...g temperature range 0 C 50 C Storage temperature range 20 C 55 C Note Exploding the device in the sun will significantly shorten the life of the LCD panel and accelerate the aging of the button panel...

Page 5: ...nected or disconnected Set as connectting internal resistance there is no need to connect external resistance When set to disconnect the internal resistance the external resistance should be connected...

Page 6: ...d well After the meter loop is connected correctly hold down the power button for three seconds and the LCD screen is lit to indicate that the device has been working Hold down the power button for th...

Page 7: ...e 3 battery power 4 local information 5 language 6 resistance connection For any type of meter you can always return to the item menu by pressing the left arrow key or the Back key several times Ifent...

Page 8: ...inspection it can achieve equipment self inspection and report the test results Selecting circuit current detection the transmitter can output a fixed current signal to verify whether the whole circu...

Page 9: ...main menu to enter the detailed Settings menu which provides more configuration information For different HART devices the detailed Settings are quite different Only through the registered device its...

Page 10: ...ntenance 3 calibration 1 output fine tuning Note the output current fine tuning function can only be performed when HART instrument leaves the factory and is tested periodically The use of this functi...

Page 11: ...unicator will automatically poll all connected devices from address 0 to address 15 The second item in the menu is single point polling You can choose any address between 0 and 15 for communication If...

Page 12: ...wer Select the third item from the item menu to enter the display battery power function which will detect the remaining battery power in the current communicator When the battery power is too low ple...

Page 13: ...ns 13 1 the communicator is not connected to the meter 1 check whether the loop equipment supports HART function 2 check the size of the circuit load resistance load resistance should be between 250 5...

Page 14: ...pull the data line to avoid the bad contact of the line and the unusable situation 14 4 please press the keyboard lightly to avoid heavy hitting and extend the life of the keyboard 14 5 batteries sho...