East Coast Datacom UDC-RDS Operation Manual Download Page 1

TABLE OF CONTENTS

Page 7

5.0 - TECHNICAL SPECIFICATIONS

. . . . . . . . . . . . . . . . .

Page 6

4.3      UNIT OVERVIEW

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 8

4.1      DELAY SETTINGS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 8

4.1      STRAP CHART CLOCK RATES

. . . . . . . . . . . . . . . . . .

Page 5

4.0 - APPENDIX

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 5

3.7      

EXTERNAL CLOCK OPTION

. . . . . . . . . . . . . . . . . . . . . . .

Page 5

3.6.1   DIP SWITCHES

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 5

3.6      SWITCH SETTINGS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 5

3.5      DATA PORT CONNECTIONS

. . . . . . . . . . . . . . . . . . . .

Page 5

3.4      DEFAULT CONFIGURATION SWITCH SETTINGS

Page 4

3.3      POWER CONNECTION

. . . . . . . . . . . . . . . . . . . . . . . . .

Page 4

3.2      VOLTAGE SELECTION FUSES

. . . . . . . . . . . . . . . . . .

Page 4

3.1      VOLTAGE SELECTION

. . . . . . . . . . . . . . . . . . . . . . . . . .

Page 4

 CHAPTER 3 - INSTALLATION

. . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 3

2.9      DATA INTERFACE REMOVAL

. . . . . . . . . . . . . . . . . . .

Page 3

2.8      CONTROL SIGNAL FORCING

. . . . . . . . . . . . . . . . . . .

Page 2

2.7      EXTERNAL CLOCK OPTION

. . . . . . . . . . . . . . . . . . . .

Page 2

2.6      DATA INTERFACES

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 2

2.5      CLOCKING

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 2

2.4      REAR PANERL DATA INTERFACE PORTS

. . . . . .

Page 2

2.3      REAR PANEL POWER CONNECTOR

. . . . . . . . . . . .

Page 2

2.2      INTERNAL SWITCHES

. . . . . . . . . . . . . . . . . . . . . . . . . .

Page 2

2.1      FRONT PANEL INDICATORS

. . . . . . . . . . . . . . . . . . . .

Page 2

CHAPTER 2 - PRODUCT OVERVIEW

. . . . . . . . . . . . . . . .

Page 1

1.1      FUNCTIONAL DESCRIPTION

. . . . . . . . . . . . . . . . . . . .

Page 1

CHAPTER 1 - INTRODUCTION

. . . . . . . . . . . . . . . . . . . . . .

Summary of Contents for UDC-RDS

Page 1: ...ETTINGS Page 4 3 3 POWER CONNECTION Page 4 3 2 VOLTAGE SELECTION FUSES Page 4 3 1 VOLTAGE SELECTION Page 4 CHAPTER 3 INSTALLATION Page 3 2 9 DATA INTERFACE REMOVAL Page 3 2 8 CONTROL SIGNAL FORCING Pa...

Page 2: ...Code Version 8Kbps to 3 072Mbps 23 January 2013 Manufactured By East Coast Datacom Inc WWW ECDATA COM FOR TECHNICAL SUPPORT CALL East Coast Datacom Inc 245 Gus Hipp Blvd STE 3 Rockledge FL 32955 USA...

Page 3: ...t its equipment is free from any defects in materials and workmanship The warranty period shall be three 3 years from the date of shipment E C D s sole obligation under its warranty is limited to the...

Page 4: ...the user to pass or force control signals The control signals are also delayed along with the user data The unit is configured via accessible front panel dip switches and is available in a stand alone...

Page 5: ...lt Factory Located on the back or rear of the product you will find an IEC POWER RECEPTACLE The supplied power cord plugs into this receptacle This receptacle also contains a fuse drawer Two 2 fuses a...

Page 6: ...ers data cables from the Data Interface Module DIM Located on back panel of the UDC RDS are PORT A and PORT B Each DIM is plugged into and out of these ports through mating connectors Remove the top c...

Page 7: ...ed with slow blow 5 x 20mm 160ma Fuses E C D Part 714000 For 220 VAC 10 operation the unit is equipped with slow blow 5 x 20mm 80ma Fuses E C D Part 714001 Spare fuses may be purchased by calling East...

Page 8: ...users cabling to the UDC RDS Data Interfaces should be connected Straight through shielded cables should be used PORT A B must always have a DCE interface module plugged into the port and connected t...

Page 9: ...4 2 UNIT OVERVIEW UDC RDS INSTALLATION AND OPERATIONS MANUAL Page 6 POWER SUPPLY POWER ENTRY FUSE DRAWER PORT A WARNING DIP SWITCHES SW1 SW2 PORT B...

Page 10: ...hes 20 86 cm Length 9 00 inches 22 86 cm Weight 2 pounds 0 914Kg Regulatory Approvals UL 60950 1 2nd Ed 2007 CAN CSA 22 2 No 60950 1 07 EN 60950 1 2006 EN 55022 2006 FCC Pt 15 ICES 003 Class A Warrant...