Safety Instructions
WARNING!!!: This product contains or generates chemicals known to the state of California to cause cancer or birth
defects or other reproductive harm.
IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or service this
fireplace. Improper use of this fireplace can cause serious injury or death from fire, burns, explosions, or carbon
monoxide poisoning.
DANGER: CARBON MONOXIDE POISONING MAY LEAD TO DEATH!
This fireplace is a vented product and will not produce any gas leakage into your home if properly installed by a qualified
service person. If this unit is not properly installed by a qualified service person, gas leakage may occur. Propane (LP) gas
and natural gas (NG) are both colorless and odorless gases. An odor-making agent is added to each of these gases to help
you detect a gas leak. However, the odor added to these gases can fade and gas may be present even though no odor exists.
CARBON MONOXIDE POISONING
: Early signs of carbon monoxide poisoning resemble flu symptoms, including headaches,
dizziness, or nausea. If you have these signs the fireplace may not have been installed properly, get fresh air at once! Have
the fireplace inspected and serviced by a qualified service person or your gas supplier. Some people are more affected by
carbon monoxide than others. These include pregnant women, people with heart or lung diseases or anemia, people at
high altitude or under the influence of alcohol. Earthcore Industries strongly recommends the use of a carbon monoxide
detector/alarm device wherever gas fired appliances are in use.
All parties either involved in or associated with the installation, service and use of this fireplace must read this entire
manual. Keep this manual for reference and as a guidebook to safe operation of this fireplace.
WARNING!!!: This unit is not for use with solid fuel.
1)
Always check local building codes governing fireplaces and fireplace installations. The Isokern Maximus Linear Series
installation must comply with all local, regional, state, and national codes and regulations.
2)
The Isokern Maximus Linear Series fireplaces are listed for use with the specific venting and burner system as detailed in
this manual only.
3)
This appliance is only for use with the type of gas indicated on the rating plate. This appliance can be field converted for
use with either Propane (LP) or Natural Gas (NG). Contact your local Isokern Sales Representative for details.
4)
For propane (LP) use do not place propane supply tank(s) inside any structure. Locate propane supply tank(s) outdoors.
To prevent performance problems, do not use propane fuel tank of less than 100 lbs. capacity.
5)
Do not install the Isokern Maximus Linear Series Gas Fireplace in a manufactured home or mobile home or recreational
vehicle.
6)
This fireplace reaches high temperature. Keep children and adults away from hot surfaces to avoid burns or clothing
ignition. Fireplace will remain hot for a time after shutdown. Allow surfaces to cool before touching.
7)
Turn the Isokern Maximus Linear Series fireplace off and allow to cool before servicing. Always shut off any electricity and
gas to the Isokern Maximus Linear Series See-Thru fireplace while working on it. Only a qualified service person should
install, service, or repair this fireplace. Have your fireplace inspected annually by a qualified service person.
8)
It is imperative that the unit’s control areas, burners, and circulation air passages be kept clean.
9)
Venting system should be inspected annually by a qualified service person. If needed have venting system cleaned or
repaired.
10)
Keep all combustible material, gasoline, and other flammable liquids at a safe distance from the fireplace. Do not use
the fireplace where these items are used or stored. Decorations, clothing, and other such combustible items should not
be placed on the fireplace.