Earth Stove 1003C Installation And Operation Manual Download Page 1

 

 

INSTALLATION AND OPERATION 

MANUAL 

 

     
 
   
 
 

  
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
                         
 

                               

    
    

 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 

MODEL 1003C 

RETAIN THESE 

INSTRUCTIONS 

FOR FUTURE 

REFERENCE 

 

EPA CERTIFIED 

CATALYTIC WOOD 

BURNING STOVE 

 

THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER. 

READ ENTIRE MANUAL THOROUGHLY BEFORE INSTALLATION. 

P/N 775003M, Rev. P, 11/03 

Summary of Contents for 1003C

Page 1: ...MODEL 1003C RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE EPA CERTIFIED CATALYTIC WOOD BURNING STOVE THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER READ ENTIRE MANUAL THOROUGHLY BEFORE INS...

Page 2: ...OR FLAMMABLE FLUIDS SUCH AS GASOLINE NAPHTHA OR ENGINE OIL 9 Never use gasoline gasoline type lantern fuel kerosene charcoal lighter fluid or similar liq uids to start or freshen up a fire in this hea...

Page 3: ...and Operation Instructions included here will assure you have many years of dependable and enjoyable service from your appliance CONGRATULATIONS ON THE PURCHASE OF YOUR NEW WOODSTOVE MANUFACTURED BY L...

Page 4: ...s of your local code Check with your local building department for requirements in your area SELECTING A LOCATION The design of your home and where you place your stove will determine its value as a s...

Page 5: ...either side The floor protection must extend completely beneath the stove and to the front sides and rear as indicated USA REQUIREMENTS 16 406 mm min to the front of the fuel door glass 8 203 mm min...

Page 6: ...3 Residential Standard not approved for manufactured mobile homes Using 6 152 mm diameter single wall connector pipe with listed factory built to the top of the stove Clearances inches millimeters A 2...

Page 7: ...this appliance REDUCED MASONRY STRUCTURE CLEARANCE ALCOVE Your stove can be installed in a masonry structure with reduced clearances if the structure was built to National Building Code for fireplaces...

Page 8: ...e to the opening in the base as location permits The air duct opening must be protected from any possible ob struction including loose floor insulation MANUFACTURED MOBILE HOME REQUIREMENTS This stove...

Page 9: ...a smoking stove is usu ally caused by a chimney problem The stove flue size is 6 152 mm diameter which is approximately 28 square inches 712 square millimeters minimum The maximum flue size should be...

Page 10: ...sealant to the following components Around the chimney at the point where the storm collar will meet the chimney just above the Flashing Along the vertical seam of the chimney pipe where it is expose...

Page 11: ...e draft gauge manufacturers instructions to create a draft test port Note Hole location should be a minimum of 1 foot above flue outlet collar 4 Start a fire See How To Start And Maintain A Fire on pa...

Page 12: ...ery 90 degrees of direction change This appliance re quires 12 to 15 feet of effective draft for optimum perform ance see Draft Requirements on page 11 First section of pipe must be vertical Use as mu...

Page 13: ...lation from the outer surface of the wall thimble to wall combustibles Support the wall thimble and cover its opening with a 24 gage minimum sheet metal support Maintain the 6 152 4 mm space There sho...

Page 14: ...nly at temperatures around 1000 F CATALYTIC BYPASS DAMPER CONTROL The operating handle of your Bypass Damper Control is located on the front of the Stove Flue Collar By moving the Bypass Damper Contro...

Page 15: ...e 19 mm door rope gasket is made of highly durable high temperature resistant mate rial It must be kept in good condition Do not leave the stove burning with the door ajar or open Leaving the door aja...

Page 16: ...he fire or the catalytic combustor going out At the end of a burn cycle it s possible that the hot em bers remaining might not provide sufficient fuel value for the catalyst to retain its minimum oper...

Page 17: ...ding agents as they can produce conditions which will deteriorate metal or dam age the catalyst Green or uncured wood does not work well as fuel and can cause increased creosote buildups and plugging...

Page 18: ...n the painted and bare sur faces Do not let the sand paper gum up with paint as this will cause scratches on the metal surface If there are any scratches use 600 grit sandpaper instead Mask off surfac...

Page 19: ...einstall door CREOSOTE FORMATION AND NEED FOR REMOVAL What is Creosote When wood is burned slowly it pro duces tar and other organic vapors which combine with expelled moisture to form creosote The cr...

Page 20: ...ly for cleaning and rein stallation is simple and convenient Cleaning the com bustor helps reduce buildup of ash and retarding chemi cals To clean the combustor a soft brush vacuum cleaner or pipe cle...

Page 21: ...re based on average climates and home design 5 There s an obstruction in the chimney 6 The chimney or chimney cap is restricted by creo sote preventing enough draw to sustain a HIGH heat rate 7 Combus...

Page 22: ...yst to peel Some minor peeling does not affect function Severe peeling would close cell openings and cause a plugging problem If peeling is severe replace combustor Do not overfire appliance See Overf...

Page 23: ...e chimney should be clean and in good repair A draft test should be performed to de termine if the draft requirements of the appliance are being met A draft gauge should read between 05 and 07 inches...

Page 24: ...877 mm Height 32 5 826 mm Approx Burn Time 8 12 hours Fuel Capacity 50 70 lbs 23 32 kg Fire Box Size 3 cubic feet 914 cubic millimeters Loading Front Catalyst Standard Maximum Burn Rate 51 100 BTU EPA...

Page 25: ...er coil handle with hook for opening closing damper bypass 11485 Housing Combustor also requires 1 each P N 11481H H0310 Probe Combustor Temperature Z SC 107 Room Air Blower Parts if optional blower i...

Page 26: ...x 4 W Notch order 8 if set is needed FB12 Firebrick 7 3 8 x 4 x 6 Left requires 1 FB13 Firebrick 7 3 8 x 4 x 6 Right requires 1 FB14 Firebrick 6 3 4 x 3 x 2 3 8 Left requires 1 FB15 Firebrick 6 3 4 x...

Page 27: ...dule Door Assembly Handle Assembly P N LB 102214 Torque Plate Nut Washers Handle Rod Coil Handle Secondary Air Tube Bypass Damper Control Damper Door Positioning Stops Tunnel Baffle Catalytic Combusto...

Page 28: ...y turn on the blower when the stove is hot and automatically turn it off when the stove is cool Outside Air Floor Duct OAFD S Outside air can be delivered for combustion air by utilizing this floor pe...

Page 29: ...SAFETY LISTING LABEL PAGE 29...

Page 30: ...EPA LABEL PAGE 30...

Page 31: ...RSHIP RECORDS Page 31 Dealer s Name Dealer s Address City State Zip Code Serial Number Date of Purchase Date Installed Notes SERVICE AND MAINTENANCE LOG Service Service Service Date Technician Descrip...

Page 32: ...1110 West Taft Avenue Orange CA 92865...