- 21 -
4.2 Weight Scale - Error Codes
Error Code Possible Cause
Solution
uuuuuu
Overloaded condition.
Wrong connection at load cell.
Load cell has quality problem.
Reduce the weight.
Check load cell connection
Inspect load cell for damage.
Check the input and output.
nnnnnn
Overloaded condition.
Bad connections.
Load cell has quality problem.
Check scale is resisted or not, foot is kept level
or not.
Check load cell connection
Check input and output resistance of load cell.
ERR1
Overweight calibration error.
Incorrect weight input or incorrect
weight on weighing platform.
Input weight correctly during calibration.
Place correct weight on weighing platform.
ERR2
Underweight calibration error.
Incorrect weight input or incorrect
weight on weighing platform.
The calibration weights Minimum is 10% of
Max. cap. Recommend 60%-80% of Max.
Capacity.
ERR3
During calibration, the input signal is
negative.
Check all connections. Check load cell. If
connections and load cell are okay, PCB needs
replacing.
ERR4
During calibration, the signal is
unstable.
After the platform is stable, start calibration.
ERR5
Circuitry error
Replace the PCB.
ERR6
System error
Call for Tech Support
Summary of Contents for 2000F Series
Page 28: ...28 6 1 Illustration Base...
Page 29: ...29...
Page 32: ...32 6 3 Illustration Mast...
Page 34: ...34 6 4 Illustration Carriage...
Page 36: ...36 36 Swing Shaft short FG 142 1 37 Micro Switch MQS 216 1...
Page 39: ...39 6 7 Illustration Film Lift Cutting Assembly...
Page 41: ...41 6 7 Illustration Film Nipping Device Assembly...
Page 43: ...43 7 Electrical Schematics...
Page 44: ...44 7 Electrical Schematics...
Page 45: ...45 7 Electrical Schematics...
Page 46: ...46 7 Electrical Schematics...
Page 47: ...47 7 Electrical Schematics...
Page 48: ...48 7 Electrical Schematics...
Page 49: ...49 7 Electrical Schematics...