Eagle 1403 Installation Manual Download Page 1

 

Rev. 4.0 2/97 

 
 
 
 

MODEL 1403 REMOTE CONTROL RELAY MODULE 

 

INSTALLATION MANUAL

 

 

1.0 GENERAL. 

 

The Model 1403 REMOTE CONTROL RELAY MODULE provides four SPDT relays which can be controlled from 
the central station.  Two Model 1403's can be daisy-chained to provide eight (8) relay control outputs.  Relays can 
be configured for momentary or latching operation; momentary delay can be programmed long or short.  There is a 
master set and reset command. 

 

2.0 REQUIREMENTS. 

 

2.1 POWER. 

 

Operating Voltage:  9 to 14 VDC. 
Current Draw (standby):   20 mA. 
Current Draw (all set):  170 mA. 

 

2.2 SYSTEM 

 

The Eagle Model 1403 requires the following hardware: 
 
 

1) Eagle Two Way Audio Verification Module (1403 ready) 

   --- 

or 

 

--- 

 

2) Eagle Remote Arm/Disarm Module (Models 1404 or 1407) 

 

3.0 CONNECTIONS. 

 

3.1 REQUIRED CONNECTIONS. 

 

INTERCONNECT CABLE.  Connect one end of the two conductor wire included with the Model 1403 to the “

IN

” 

connector on the Model 1403.  Connect  the other end of the cable to the “

1403

” connector on the 1250 or 

P7

 on 

the Model 1241 or to 

P1

 on the Model 1404.  See appropriate manual to connecting Eagle modules for further 

instructions. 
 
POWER CONNECTIONS.  The Model 1403 re12VDC and GROUND connections.  These connections 
may be made to any +12VDC supply available including the Model 1241 or Model 1404 terminal strips.   

 

3.2 OPTIONAL CONNECTIONS. 

 
MULTIPLE MODEL 1403's.  If it is desired to use more than one (1) Model 1403, an additional Model 1403 may be 
interconnected via the two conductor cable in a daisy chain configuration.  Connector P2 is the output on Model 
1403 for additional modules.  Connect P2 of the first module to P1 of the second module.  BE SURE TO 
CONFIGURE EACH MODULE TO DIFFERENT NUMBER BANKS (1 through 4 or 5 through 8) FOR REMOTE 
CONTROL (See paragraph 4.1.) 

 
 
 