What the MicroSensor Does
The MicroSensor is a precision instrument that uses a Prandtl style pitot-static tube to measure airspeed, just as full sized planes do.
Advanced temperature compensation and calibration ensure the best possible accuracy. When used standalone, the MicroSensor displays
your maximum speed on the built-in 7 segment LED display. Additionally, the MicroSensor can be connected to your eLogger (any
version) to provide airspeed data for your entire flight. When connected to the eLogger, airspeed can be displayed and graphed using the
eLogger’s Windows software.
IMPORTANT:
It is extremely unlikely that the installation of the MicroSensor will affect your model’s radio range or control. But, as
always after making an electronics change to your model, it is very important that you range and function test your model once the
MicroSensor is installed to ensure that there is no impact on your system.
Packing List
Your package should include the following: The MicroSensor, a machined brass and aluminum Prandtl style pitot-static tube, the Standalone
Cable, two lengths of approximately 3 foot (1 meter) small diameter silicon hose, and a printed version of this manual. NOTE: Additional
Pitot Tube kits are available for purchase on our website, for use with multiple models.
Installing the Pitot Tube and MicroSensor in your Model
Using two lengths of the included small diameter silicon tube, the pressure and static connections of the pitot tube connect to the “+” and “-”
ports of the MicroSensor, respectively, as shown in Figure 1. It is best to mount the pitot tube in your model first, then determine where
you will mount the MicroSensor, and then cut the two lengths of silicon tube so they reach between the two.
Follow these guidelines when mounting the pitot tube:
1.
The pickup end of the pitot tube (the silver colored tip) should be pointing toward the direction of the model’s travel. While best results
will be obtained if the pitot tube is perfectly aligned with the direction of travel in both axes, the “Prandtl” design of the tube will
compensate somewhat for higher angles of attack.
2.
The static holes on the pitot
tube (shown on Figure 1)
should extend at least 1/2”
(13mm) past the wing’s
leading edge, or past any other
obstructions - the farther out,
the better. This is to ensure
that the static holes and pitot
pickup are in undisturbed air.
3.
For prop planes, it’s important
that the tube be placed so that
it is not directly in the plane’s
prop-wash, which will result in
erroneous readings. The best
place to install the tube is on
the leading edge of the wing