background image

 

Installation Manual SW108 

 

 

 

EAE KNX Switch Actuator 8ch 

            

SW108 IM R2.0

 

 

 

© EAE Technology

 

                                                

www.eaetechnology.com

 

Ikitelli Org. San. Bolg. Ziya Gokalp Mah. Eski Turgut Ozal Cad. 

No: 20, Zip Code:

 

34490

 

Basaksehir/Istanbul

 

Tel:

 

+90 212 549 97 13                                                    

 

       

 

Connection 

1.

 

Physical address label 

2.

 

KNX programming key 

3.

 

Red KNX programming led 

4.

 

KNX connection terminal 

5.

 

Switch position display and ON / OFF manual actuation 

Description of Device 

Device has eight channels which can be configured with ETS3/ETS4 or higher 

version. Each channel is independent of one other. It has a separate bistable 

switching relay. Also device has manual operating feature. The relay can be 

switched on or off with slide switches. There is no feedback to the bus in this case. 

The following function list provides; 

 

Staircase 

 

External logic 

 

Internal logic 

 

Priority 

 

Threshold 

 

Operating hour  

 

Sweep 

Each channel of devices can choose any of these functions. The outputs are 

parameterized individually via ETS3/4 or higher version. After bus voltage failure or 

voltage return, relay position is selected by dependence on parameters. In “ETS 

reset”, device parameters are return download configuration.  

Technical Data 

Protection Type  IP20 

EN 60 529 

Safety class 

II 

EN 61 140 

Power 

KNX 

21V… 30V DC, SELV 

Connection 

Screw terminals 

0,5…4  mm² solid and stranded wire  

0,5…2,5mm² stranded wire with 

ferrule 

 

Max tight torque  0.8 Nm 

 

KNX 

Bus connection terminal 

Output 

Count 

 

Switching 

voltage 

277/440V AC; 50/60 Hz 

 

Switching 

capacity 

277 V AC  16A / AC 1 

 

Fluorescent 

lighting load 

EN60 669-1   16 AX/250 VAC 

Output life 

Mechanical life 

> 3 x 10

6

 

Installation 

35 mm 

mounting rail 

EN 60 715 

Temperature 

Ambient 

Storage 

-5° C   + 45° C 

-25° C   + 55° C 

Humidity 

Max. Humidity 

95 % non condense 

Dimensions 

65,5 x 143 x 89mm 

Weight 

0.30 kg 

Box 

Plastic, polycarbonate, colour grey 

CE 

In accordance with the EMC guideline and LV directives 

Operation and Display 

-Display of switch position

 (5) 

-On/Off manual operation 

The contact position shows the current situation of load circuit. It can be changed 

manually ON and OFF position. 

-Programming Led

 (3) 

Red led lights up after the programming button is

 

pressed.

 

Installation 

The device is compatible for mounting to 35 mm DIN rail EN 60 715. 

Connection 

KNX connector must be connected to the KNX connection terminal. Ensure that 

colour of cables are connected accurate. Load connections are made using screw 

terminals. Different phase lines can be connected to load channels at the same 

time. (L1, L2, L3) 

 

 

 

 

 

 

 

Scale Drawing 

Commissioning 

Determination of the physical address and setting of parameters are actualized 

with Engineering Tool Software (ETS3/ETS4 or higher). “.knxprod” file must be 

imported to the ETS. Please check website for latest “.knxprod” file. 

www.eaetechnology.com

 

 A detailed information about parameter configuration can be found in 

Product Manual of device. 

 

 

Installation and commissioning of device may only be implemented by trained 

electricians. The relevant standards, directives, regulations and instructions must 

be observed when planning and implementing the electrical installation. 

-When connecting the device make sure that the device is isolated! 

-Protect the device against moisture, dirt and damage during transport, storage 

and operation! 

-Do not operate the device out of the specified technical data which is stated. 

-The device may only be operated in closed enclosures (Distribution boards etc.) 

Cleaning 

If device becomes dirty, only a dry cloth can be used for cleaning. It is not suitable 

to use wet cloths, caustics and solvents. 

Reviews: