background image

N6081 Series

Operation Manual

Summary of Contents for N6081 series

Page 1: ...N6081 Series Operation Manual...

Page 2: ......

Page 3: ...e2v technologies N6081 Series Operation Manual e2v technologies 2004 HBN6081 1 Issue 5 January 2004 186 3591...

Page 4: ...RF connectors must be correctly fitted before operation so that there is no leakage of RF energy The control unit must not be operated unless the RF output connection is correctly terminated It is par...

Page 5: ...2v technologies quality management system is certificated to the requirements of ISO 9001 CUSTOMER CARE Stellar 24 Hour Hotline In the event of a Stellar product fault or urgent application enquiry di...

Page 6: ...Warm up 7 4 4 Standby 7 4 5 Transmit 7 4 6 Off 7 4 7 Fault 7 5 Measurement and Monitor Functions 8 5 1 Power watts 8 5 2 Power dBW 8 5 3 Helix Current 8 6 Gain Setting Only available on the N6081D 8...

Page 7: ...n Storage temperature range is from 740 to 70 8C Do not use control unit boxes to support the weight of any other item Retain the control unit boxes for future use Avoid severe shocks 2 2 Handling The...

Page 8: ...The N6081 is used to control an amplifier from the following product series N61xx e g N6132D N6150D N63xx e g N6312 N6318D N64xx e g N6440 4 1 Applying The Voltage Supply The N6081 requires no externa...

Page 9: ...r 180 seconds the XMIT LED will light and the WARM UP LED will go out The amplifier will operate Amplifier fan will rotate at full speed Display will now show the output power in watts If the XMIT key...

Page 10: ...et Gain result in watts This feature can be selected by pressing the function select button once more This will allow the digital attenuator to be set on the amplifier This is achieved by turning the...

Page 11: ...ions see also Appendix A 41 way amplifier 15 way D type connector connector A 2 B 4 C 3 D 5 E 6 H P R p 14 J 7 K 8 L 9 U 1 b 10 c 11 d 13 e 12 Notes Cable for b and c must be a twisted pair Cable for...

Page 12: ...voltage 15 V current 100 mA 9 2 Mechanical Dimensions 19 inch rack width 483 mm 19 inches height 1U 44 mm 1 73 inches depth 50 mm 2 inches depth with allowance for connectors and bend radius of cable...

Page 13: ...120R 1 4W 120R 1 4W 120R 1 4W Appendix A 41 way Stellar 15 way D type Amplifier connector Controller connector A 2 B 4 C 3 D 5 E 6 H 14 J 7 K 8 L 9 P R U 1 b 10 c twisted pairs 11 d 13 e 12 p...

Page 14: ...7 5 4 19 2 25 9 24 23 21 22 20 1 3 10 11 12 13 14 15 16 17 18 26 9 WAY D SOCKET SK1 1 2 3 4 5 6 7 8 9 OFF S O WARM UP LED STDBY LED XMIT LED FAULT S O OFF SWITCH STDBY SWITCH XMIT SWITCH Vin 15 V RX R...

Page 15: ...transmit mode 18 Other see comments 24 RF load too hot 9 No output power 25 LV PSU fault 10 Other see comments 26 Bad HV rail Difficulties With Control Panel Or Remote Interface 27 Set up 31 Hour cou...

Page 16: ......

Page 17: ...F 91572 BIE VRES Cedex Telephone 331 6019 5500 Facsimile 331 6019 5529 USA e2v technologies inc 4 Westchester Plaza Elmsford NY 10523 1482 Telephone 914 592 6050 Facsimile 914 592 5148 Canada e2v tech...