_______________________________________________________________________________________________________________________________
European Safety Systems Ltd.
Impress House, Mansell Road, Acton, London W3 7QH www.e2s.com
Tel: +44 (0)208 743 8880
Document No. D204-00-201-IS
Issue 8
10-09-2023
Sheet 1 of 6
1) Warnings
•
USE COVER BOLTS CLASS A4-70
•
DO NOT OPEN WHEN AN EXPLOSIVE
ATMOSPHERE IS PRESENT
•
POTENTIAL ELECTROSTATIC HAZARD
•
ALL ENTRIES M20 X 1.5
•
DO NOT OPEN WHEN ENERGIZED
•
IF TEMPERATURE EXCEEDS 70°C AT
ENTRY OR 80°C AT BRANCHING POINT
USE SUITABLE RATED CABLE AND CABLE
GLANDS
2) Rating & Marking Information
2.1 ATEX / IECEx / UKEX Certification
All units have a rating label, which carries the following
important information:-
Model No.:
STExCP8-PB-S (Single Switch)
STExCP8-PB-D (Dual Switch)
STExCP8-PB-S-L or -C (Single Switch
with LED
STExCP8-PM-S (Single Switch)
STExCP8-PM-D (Dual Switch)
STExCP8-PM-S-L or -C (Single Switch
with LED
STExCP8-PT-S (Single Switch)
STExCP8-PT-D (Dual Switch)
STExCP8-PT-S-L or -C (Single Switch
with LED
Input Voltage:
DC Units 48Vdc Max
AC Units
250Vac max (units without
series , end-of-line or LED devices only)
STExCP8-PB-S ; -PM-S ; -PT-S Codes:
Ex db IIC T6 Gb Ta. -55°C to +70°C
STExCP8-PT-S-L or -C ; STExCP8-PM-S-L or -C ;
STExCP8-PB-S-L or -C Codes:
Ex db IIC T5 Gb Ta. -55 to +70°C
Ex db IIC T6 Gb Ta. -55 to +65°C
STExCP8- PB-D ; -PM-D ; -PT-D Codes:
Ex db IIC T5 Gb Ta. -55°C to +70°C
Ex db IIC T6 Gb Ta. -55°C to +60°C
STExCP8-PT-D-L or -C ; STExCP8-PM-D-L or -C ;
STExCP8-PB-D-L or -C Codes:
Ex db IIC T4 Gb Ta. -55 to +70°C
Ex db IIC T5 Gb Ta. -55 to +65°C
Ex db IIC T6 Gb Ta. -55 to +50°C
Certificate No.
DEMKO 15 ATEX 1589X
IECEx ULD 15.0018X
UL21UKEX2133X
UKCA Marking
Notified Body No.
The units can be installed in locations with the following
conditions:
Area Classification Gas:
Zone 1
Explosive gas air mixture likely to occur in
normal operation.
Zone 2
Explosive gas atmosphere not likely to
occur in normal operation but may be
present for short periods.
Gas Groupings:
Group IIA
Propane
Group IIB
Ethylene
Group IIC
Hydrogen and Acetylene
2813
II 2G
ATEX Marking
Equipment Group and
Category:
CE Marking
Notified Body No.
INSTRUCTION MANUAL
(ATEX / IECEx / UKEX / DNV)
STExCP8-PB-S, STExCP8-PB-D, STExCP8-PM-S, STExCP8-PM-D,
STExCP8-PT-S & STExCP8-PT-D CALL POINTS
For use in Flammable Gas Atmospheres and Marine Environments
STExCP8-PB
STExCP8-PT
STExCP8-PM
0518