FIRE INSTRUCTION & SERVICE MANUAL
D2xL1F, D2xL2F & D2xL2H
European Safety Systems Ltd.
Impress House, Mansell Road, Acton, London W3 7QH
www.e2s.com
Tel: +44 (0)208 743 8880
Document No. D252-00-201-IS-UL
Issue A
28-09-2023
Sheet 1 of 2
D2xL1FV100, D2xL2FV100, D2xL2HV100, D2xL1FV725, D2xL2FV725, D2xL2HV725, D2xL1FR008, D2xL2FR008, D2xL2HR008, D2xL1FR016,
D2xL2FR016 & D2xL2HR016 are approved for use as Loudspeakers for Fire Alarm Systems: UL1480 (Ed 6)
CAN/ULC-S541 (Ed 4)
Attention: Installation must be carried out by an electrician in compliance with the National Electrical Code, NFPA 70, and the National Fire
Alarm Signaling Code, NFPA 72 or CSA 22.1 Canadian Electrical Code, Part I, Safety Standard for Electrical Installations, Section 32. /
L'installation doit exclusivement être réalisée par du personnel qualifié, conformément au code national d'électricité américain, NFPA 70, et
le code national d’alarrme incendie et de signalisation N P 72 ou S 22.1 ode canadien de l'électricité, première partie, norme de
sécurité relative aux installations électriques, Section 32
Attention: Disconnect from power source before installation or service to prevent electric shock / Débranchez-le de la source d'alimentation
avant l'installation ou l'entretien pour éviter tout choc électrique.
Attention: Fire Alarm Device
—Do not paint / Ne pas Peinturer— ispositif ’ larme
Attention: Do not change factory applied finishes / Ne pas changer le revetement applique en usine
•
Type 4 / 4X / 3R / 13, IP66/IP67
•
-55°C to +80°C / -67°F to +176°F
•
Units should be mounted using at least 2 of the 3-off/4-off ø7mm holes in the mounting bracket.
•
The Equipment must not be installed with the horn facing upwards of horizontal.
•
If a high IP (Ingress Protection) rating is required then a suitable sealing washer or O-ring must be fitted under any cable gland or blanking device
with metric threads.
•
heck that the ‘ ’ ring seal is in place before replacing the cover.
•
To maintain the enclosure rating, the cable entries must be fitted with suitably rated cable entry and/or blanking devices or suitably sized conduit
during installation. If entries are fitted with adaptors they must be suitable for the application.
•
Connections are to be made into the terminal blocks using solid or stranded wire, sizes 0.5-2.5mm
2
/ AWG 20-14. Wire insulation needs to be
stripped 8mm. Wires may be fitted securely with crimped ferrules. Terminal screws need to be tightened down with a tightening torque of 0.45 Nm
/ 4 Lb-in.
•
A single wire with a cross sectional area of up to 2.5mm² / AWG14 can be connected to each terminal way. When connecting wires to the terminals
great care should be taken to dress the wire so that when the cover is inserted into the chamber the wires do not exert excess pressure on the
terminal blocks.
•
Units can be located indoor or outdoor wet use, wall or ceiling mounted.
D2xL1FV725, D2xL2FV725, D2xL2H725 Wiring Terminals
D2xL1FV100, D2xL2FV100 & D2xL2HV100 Wiring Terminals
1
2
7
12.
1
2
D2xL1FV725
D2xL2FV725,
D2xL2HV725
Terminals
Voltage
Voltage
70.7V
25V
70.7V
25V
COM - A
-
15W
-
25W
COM - B
-
7.5W
-
12.5W
COM - C
15W
5W
25W
6W
COM - D
7.5W
4W
12.5W
4W
COM - E
5W
2W
6W
2W
COM - F
4W
-
4W
1W
COM - G
2W
-
2W
-
COM - H
-
-
1W
-
Terminals
D2xL1FV100 D2xL2FV100,
D2xL2HV100
COM
– 25W/15W
15W
25W
COM
– 12.5W/7W
7W
12.5W
COM
– 6W/3W
3W
6W
COM
– 2W/1W
1.1W
2.1W