background image

INSTRUCTION MANUAL 

D1xS2 
Alarm Horn Sounder

 

Class II/III, Zone 20

 

 

European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH

 

www.e2s.com

 

Tel: +44 (0)208 743 8880

 

Document No. D190-00-151-IS

 

Issue 1

 

03-02-2022

 

 

Sheet 1 of 7

 

 

 

 
 

D1xS2F

 

D1xS2H

 

 

 

1) 

Product Table 

 

Unit Type Code 

Nominal 

Input Voltage 

Nominal 

Current P2 

Nominal 

Current P3 

Voltage Range 

Sound 

Pressure Level 

dB(A) 

Max* 

P2/P3 

Nom

.† 

P2/P3

 

 

D1xS2FDC024-D 

12Vdc 

289mA 

356mA 

11.5-54Vdc 

103/106  98/102 

24Vdc 

324mA 

740mA 

48Vdc 

195mA 

391mA 

D1xS2FAC230-D 

115Vac 

125mA  

282mA  

100-240Vac 50/60Hz 

230Vac 

78mA 

167mA 

D1xS2HDC024-D 

12Vdc 

289mA 

356mA 

11.5-54Vdc 

106/109  103/105 

24Vdc 

324mA 

740mA 

48Vdc 

195mA 

391mA 

D1xS2HAC230-D 

115Vac 

125mA  

282mA  

100-240Vac 50/60Hz 

230Vac 

78mA 

167mA 

*Max = Tone 4 

Nom. = Tone 44 

 
The table shows the input current taken by the various sounders. 
The current levels shown above are for the 440Hz Continuous tone @ nominal input voltage.  
Nominal current at nominal voltage. 
Table 1: Electrical Ratings. 

 

2) 

Warnings 

 

 

 

 
 
CAUTION 
TO  REDUCE  THE  RISK  OF  IGNITION  OF  HAZARDOUS 
ATMOSPHERES: 
DISCONNECT FROM SUPPLY BEFORE OPENING. 
KEEP TIGHTLY CLOSED WHEN IN OPERATION. 
WARNING 
FIT  SEALING  FITTING  IN  CONDUIT  RUNS  WITHIN  18  INCHES 
FROM ENCLOSURE. 
EQUIPMENT MUST NOT BE INSTALLED WITH THE HORN FACING 
UPWARDS OF HORIZONTAL 
DO  NOT  OPEN  WHEN  AN  EXPLOSIVE  ATMOSPHERE  IS 
PRESENT  
DO NOT OPEN WHEN ENERGISED  
POTENTIAL  ELECTROSTATIC  CHARGING  HAZARD  -  CLEAN 
ONLY WITH A DAMP CLOTH  
ENCLOSURE ENTRIES: TWIN M20 X 1.5 / SINGLE 1/2” NPT 
ATEX/IECEx INSTALLATIONS: IF TEMPERATURE EXCEEDS 70°C 
AT  ENTRY  OR  80°C  AT  BRANCHING  POINT  USE  SUITABLE 
RATED CABLE AND GLANDS 
 
 

 
 
 
 
ATTENTION 
POUR 

REDUIRE 

LE 

RISQUE 

D’INFLAMMATION 

DES 

ATMOSPHÈRES DANGEREUSES : 
COUPER L 'ALIMENTATION AVANT OUVERTURE. 
CONSERVER FERMÉ PENDANT LE FONCIONNEMENT. 
AVERTISSEMENT 
CONDUITS DOIVENT ETRE SCELLES EN MOINS DE 18 POUCES. 
ÉQUIPEMENT  NE  DOIT PAS  ETRE INSTALLE  AVEC  LE  KLAXON 
TOURNEE VERS LE HAUT DE HORIZONTAL. 
NE PAS OUVRIR UN PRESENCE D’ATMOSPHERE EXPLOSIVE  
NE PAS OUVRIR ENERGIE  
DANGER POTENTIEL CHARGE ÉLECTROSTATIQUE - NETTOYER 
UNIQUEMENT AVEC UN CHIFFON HUMIDE  
ENTRÉES DE BOÎTIER: 2 x M20 X 1.5 / 1 x 1/2” NPT 
ATEX/IECEx  INSTALLATIONS :  SI  LA  TEMPÉRATURE  DÉPASSE 
70  °C  À  L'ENTRÉE  OU  80  °C  AU  POINT  DE  BRANCHEMENT, 
UTILISER 

UN 

CÂBLE 

ET 

DES 

JOINTS 

D'ÉTANCHÉITÉ 

APPROPRIÉS 
  
 
 

Summary of Contents for D1xS2FAC230-D

Page 1: ...RDOUS ATMOSPHERES DISCONNECT FROM SUPPLY BEFORE OPENING KEEP TIGHTLY CLOSED WHEN IN OPERATION WARNING FIT SEALING FITTING IN CONDUIT RUNS WITHIN 18 INCHES FROM ENCLOSURE EQUIPMENT MUST NOT BE INSTALLE...

Page 2: ...arth conductor under the earth clamp The earth conductor should be at least equal in size and rating to the incoming power conductors but at least a mini mum of 0 82mm2 18AWG in size External earthing...

Page 3: ...kwise and remove the cover Take extreme care not to damage the explosionproof threads in the process 6 Installation Requirements 6 1 Safe Installation Requirements Warning High voltage may be present...

Page 4: ...be supplied with the following types of adapters M20 to NPT M20 to NPT M20 to M25 It is important to note that stopping plugs cannot be fitted onto adapters only directly onto the M20 entries Any oth...

Page 5: ...005 wiring options Config Voltage Configuration Description Features Product Option Identifier 1a DC Single Stage Configuration Line monitoring Positive Switching 1 1b DC Two Stage Configuration Commo...

Page 6: ...8 End of Line Resistor placement 8 2 Custom DC Multi Stage End Of Line Monitoring An optional 12 way terminal module is available to enable up to four alarm stages to be activated from three DC voltag...

Page 7: ...ces may be fitted between the ve ve terminals of the PCBA Please ensure that the device legs meet the wire size range stated for the connection terminals and are fitted correctly in order to avoid a s...

Page 8: ...0 0 0 1 0 1 0 0 0 0 1 1 0 0 0 1 1 1 0 0 0 0 0 0 1 0 0 1 0 0 1 0 0 0 1 0 1 0 0 1 1 0 1 0 0 0 0 1 1 0 0 1 0 1 1 0 0 0 1 1 1 0 0 1 1 1 1 0 0 0 0 0 0 1 0 1 0 0 0 1 0 0 1 0 0 1 0 1 1 0 0 1 0 0 0 1 0 1 0 1...

Page 9: ...INE MONITORING RESISTOR CUSTOMER SUPPLIED 14V MAX SYSTEM 120 MIN 2W MIN OR 1K MIN 0 5W MIN 28V MAX SYSTEM 470 MIN 2W MIN OR 2 4K MIN 0 5W MIN RECOMMENDED MINIMUM VALUES R1 Stage 1 ve IN Stage 1 ve OUT...

Page 10: ...n ve OUT Stage 1 ve OUT Stage 3 ve Stage 1 ve IN H2 H1 Stage 1 ve Stage 1 ve Stage 2 ve Stage 2 ve OF 2 3 R1 S2 S3 R1 S2 R2 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED 14V MAX SYSTEM 120 MIN 2...

Page 11: ...er to Stage 2 ve Stage 2 ve Two Three Stage Voltage Free Activation Configuration Config 5 Customer Set H1 H2 to Negative Switching See Below Power ve ve Stage 1 Connect Stage 1 ve to Common ve Stage...

Page 12: ...5 R S RAIT B ISARD R N POTTS OF NTS 1 SWITCHES FOR STAGE OPERATION CUSTOMER SUPPLIED 1 Earth Earth Stage 2 Stage 3 Common Live IN Live OUT Neutral IN Neutral OUT Earth Stage 1 Stage 2 Common N N L L E...

Reviews: