E2S D1xL1FV725-A Instruction Manual Download Page 1

INSTRUCTION MANUAL 

D1xL1 & D1xL2 
Loudspeaker

 

Class I, Zone 1, 2, 21 & 22

 

 

European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH

 

www.e2s.com

 

Tel: +44 (0)208 743 8880

 

Document No. D190-00-201-IS

 

Issue 3

 

21-12-2023

 

 

Sheet 1 of 6

 

 

 
 

 

 

D1xL1F 

D1xL2F 

D1xL2H 

1) 

Product Table 

Unit Type Code 

Input  

Power (Watts) 

Max I/P Volts 

Sound Pressure Level dB(A) 

Max Rated 

Pink Noise @ 1W 

D1xL1FV100-A 

100V Line 

15 

100 

117 

101 

D1xL1FV070-A 

70V Line 

15 

70 

D1xL1FR008-A 

8 Ohm 

15 

10.95 

D1xL1FR016-A 

16 Ohm 

15 

15.49 

D1xL1FV725-A 

25V 

15 

25V 

70V 

15 

70.7V 

D1xL2FV100-A 

100V Line 

25 

100 

123 

104 

D1xL2FV070-A 

70V Line 

25 

70 

D1xL2FR008-A 

8 Ohm 

25 

14.14 

D1xL2FR016-A 

16 Ohm 

25 

20 

D1xL2FV725-A 

25V 

25 

25V 

70V 

25 

70.7V 

D1xL2HV100-A 

100V Line 

25 

100 

126 

106 

D1xL2HV070-A 

70V Line 

25 

70 

D1xL2HR008-A 

8 Ohm 

25 

14.14 

D1xL2HR016-A 

16 Ohm 

25 

20 

D1xL2HV725-A 

25V 

25 

25V 

70V 

25 

70.7V 

Frequency Range: 400Hz to 8000Hz 

The table shows the input current taken by the various Loudspeakers. 
Nominal current at nominal voltage. 

Table 1: Electrical Ratings. 

2) 

Warnings 

 

 

 
CAUTION 
TO 

REDUCE 

THE 

RISK 

OF 

IGNITION 

OF 

HAZARDOUS 

ATMOSPHERES: 
DISCONNECT FROM SUPPLY BEFORE OPENING. 
KEEP TIGHTLY CLOSED WHEN IN OPERATION. 
WARNING 
FIT SEALING FITTING IN CONDUIT RUNS WITHIN 18 INCHES FROM 
ENCLOSURE. 
EQUIPMENT  MUST  NOT  BE  INSTALLED  WITH  THE  HORN  FACING 
UPWARDS OF HORIZONTAL 
DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT  
DO NOT OPEN WHEN ENERGISED  
POTENTIAL  ELECTROSTATIC  CHARGING  HAZARD  -  CLEAN  ONLY 
WITH A DAMP CLOTH  
ENCLOSURE ENTRIES: TWIN M20 X 1.5 / SINGLE 1/2” NPT 
ATEX/IECEx & UKEx INSTALLATIONS: IF TEMPERATURE EXCEEDS 
70°C  AT  ENTRY  OR  80°C  AT  BRANCHING  POINT  USE  SUITABLE 
RATED CABLE AND GLANDS 

 

ATTENTION

 

POUR REDUIRE LE RISQUE D’INFLAMMATION DES ATMOSPHÈRES 
DANGEREUSES : 
COUPER L 'ALIMENTATION AVANT OUVERTURE. 
CONSERVER FERMÉ PENDANT LE FONCIONNEMENT. 
AVERTISSEMENT 
CONDUITS DOIVENT ETRE SCELLES EN MOINS DE 18 POUCES. 
ÉQUIPEMENT  NE  DOIT  PAS  ETRE  INSTALLE  AVEC  LE  KLAXON 
TOURNEE VERS LE HAUT DE HORIZONTAL. 
NE PAS OUVRIR UN PRESENCE D’ATMOSPHERE EXPLOSIVE  
NE PAS OUVRIR ENERGIE  
DANGER  POTENTIEL  CHARGE  ÉLECTROSTATIQUE  -  NETTOYER 
UNIQUEMENT AVEC UN CHIFFON HUMIDE  
ENTRÉES DE BOÎTIER: 2 x M20 X 1.5 / 1 x 1/2” NPT 
ATEX/IECEx  &  UKEx  INSTALLATIONS :  SI  LA  TEMPÉRATURE 
DÉPASSE  70  °C  À  L'ENTRÉE  OU  80  °C  AU  POINT  DE 
BRANCHEMENT, 

UTILISER 

UN 

CÂBLE 

ET 

DES 

JOINTS 

D'ÉTANCHÉITÉ APPROPRIÉS 

 

Summary of Contents for D1xL1FV725-A

Page 1: ...GNITION OF HAZARDOUS ATMOSPHERES DISCONNECT FROM SUPPLY BEFORE OPENING KEEP TIGHTLY CLOSED WHEN IN OPERATION WARNING FIT SEALING FITTING IN CONDUIT RUNS WITHIN 18 INCHES FROM ENCLOSURE EQUIPMENT MUST...

Page 2: ...AEx db IIC T4 Gb Ta 55 C to 75 C Class I Zone 1 AEx db IIC T5 Gb Ta 55 C to 70 C Class I Zone 1 AEx db IIC T6 Gb Ta 55 C to 55 C Zone 21 AEx tb IIIC 91 C Db Ta 55 C to 75 Class Zone Ratings for Canada...

Page 3: ...and erection EN60079 10 1 IEC60079 10 1 Explosive atmospheres Classification of areas Explosive gas atmospheres EN60079 10 2 IEC60079 10 2 Explosive atmospheres Classification of areas Explosive dust...

Page 4: ...o section 7 4 c Fit an M20 NPT suitably rated cable gland or conduit entry into the hole in the enclosure and connect the field wiring to the appropriate terminals as shown in D190 06 201 The power su...

Page 5: ...ghtening torque of 0 45 Nm 3 5 Lb in Line In 0 2 2 5mm2 AWG24 AWG14 Low Impedance 0 2 4mm2 AWG24 AWG12 Figure 3 Wire Preparation When connecting wires to the terminals great care should be taken to dr...

Page 6: ...nd of Line Monitoring DC Units On D1xL2 and D1xL1 Loudspeakers DC line monitoring can be used if required Both the Line In units and the Low Impedance units have blocking capacitors fitted It should b...

Page 7: ...ing bracket The Equipment must not be installed with the horn facing upwards of horizontal If a high IP Ingress Protection rating is required then a suitable sealing washer or O ring must be fitted un...

Page 8: ...14V 102 66 D1xL2HR016 16 Ohm 25W 20 00V 102 68 CAN ULC S 541 Directional Characteristics Unit Type Code Rated Angle Horizontal Axis Vertical Axis 3dB A 6dB A Reduction 90 3dB A 6dB A Reduction 90 D1x...

Page 9: ...M DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D190 06 201 D HOWGILL R N POTTS R N POTTS 18 11 20 OF NTS 1 5 A INTRODUCTION D H 18 11 20 18 11 20 18 11 20 D1xL1 D1xL2 LINE IN LOW IM...

Page 10: ...ONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D190 06 201 D HOWGILL R N POTTS R N POTTS 18 11 20 OF NTS 2 5 18 11 20 18 11 20 D1xL1 D1xL2 LINE IN LOW IMPEDANCE LOUDSPEAKER...

Page 11: ...LS STANDARDS MOD No REASON INITIAL DATE ISSUE DATE APPROVED CHECKED DATE DATE DRAWN WEIGHT Kg SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT SCALE ALL DIMENSI...

Page 12: ...H 18 11 20 18 11 20 18 11 20 D1xL1 D1xL2 LINE IN LOW IMPEDANCE LOUDSPEAKER WIRING DIAGRAMS D1xL1 D1xL2 1 INTRODUCTION RSR 16 03 22 ve ve COM A B D1xL1V725 Line in Config 4a Optional Line Monitoring 1...

Page 13: ...AMS D1xL1 D1xL2 1 INTRODUCTION RSR 16 03 22 D1xL2V725 Line in Config 5a Optional Line Monitoring 25W 25V Apply Signal to Common A 70V Apply Signal to Common C OPTIONAL LINE MONITORING RESISTOR CUSTOME...

Page 14: ...on Service Notified Body No 2813 Unit 6 Hawarden Industrial Park Hawarden Deeside CH5 3US UK Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment II 2G Ex db...

Page 15: ...and electronic equipment including amendment by Directive 2015 863 EU Regulation EC 1907 2006 Registration Evaluation Authorisation and Restriction of Chemicals REACH The product and all the component...

Page 16: ...9 31 2014 Directive 2014 30 EU Electromagnetic Compatibility Directive EMC Standards applied EN 61000 6 1 2007 EN 61000 6 2 2005 EN 61000 6 3 2007 A1 2011 AC 2012 EN 61000 6 4 2007 A1 2011 Regulation...

Page 17: ...rmity Other Standards and Regulations EN 60529 1992 A2 2013 Degrees of protection provided by enclosures IP code enclosure rated IP66 67 On behalf of European Safety Systems Ltd I declare that on the...

Page 18: ...Page left Intentionally blank...

Page 19: ...Page left Intentionally blank...

Page 20: ...Page left Intentionally blank...

Reviews: