E2S AlertAlight AL121H Instructions/Service Manual Download Page 1

 

        

 

 

 

 

 

 

INSTRUCTION & SERVICE MANUAL

 

AL121H AlertAlight Combined Sounder LED 

 

 

E2S Warning Signals Impress House, Mansell Road, Acton, London W3 7QH    [email protected]        e2s.com                                             D221

-

00

-

351

-

IS Issue 3 09/08/2021 

 

Unit Type Code

 

Nominal 

Voltage

 

Voltage Range

 

Nominal Beacon 

Current*

 

Nominal Sounder 

Current*

 

P2 / P3

 

Nominal SPL

 

P2 / P3

 

Max SPL

 

P2 / P3

 

Average SPL

 

P2 / P3

 

AL121HDC024 

 

#

12 Vdc 

 

11.5

-

14Vdc 

 

79.5mA

 

376mA / 440mA

 

116.9dB(A) / 

120.2dB(A) 
Tone 44 @ 

1m

 

120.7dB(A) / 

123.4dB(A) 

Tone 4 @ 1m

 

115.3dB(A) / 

118.1dB(A) 

 

All Tones @ 

1m

 

24 Vdc 

 

16

-

33 Vdc 

 

87mA

 

430mA / 930mA

 

AL121HDC048 

 

48 Vdc 

 

48

-

54 Vdc

 

60mA

 

223mA / 453mA

 

115 Vac 

 

100

-

240 Vac  

50/60Hz  

 

34mA

 

173mA / 340mA

 

AL121HAC230

 

230 Vac 

 

100

-

240 Vac  

50/60Hz  

 

19mA

 

105mA / 212mA

 

 *Nominal current at nominal voltage; 

#

Factory Default setting 24Vdc, beacon customer settable to 12Vdc

 

• 

-

40°C to +66°C (104°F to 151°F)

 

• 

Type 4 / 4X / 3R / 13, IP66

 

• 

2.7Kg (5.94lb)

 

• 

CE, All units UL Listed

 

0.4Nm

 

5mm

0.5   2.5mm 

Attention

: Installation must be carried out by an electrician in compliance with the latest codes and regulations.

 

Attention

: L'installation doit être effectuée par un électricien conformément aux derniers codes et réglementations. 

 

Achtung

: Die Installation muss von einem Elektriker gemäß den neuesten Vorschriften und Bestimmungen durchgeführt werden.

 

Attenzione

: L'installazione deve essere eseguita da un elettricista in conformità con i codici e le normative più recenti.

 

Atención

: La instalación debe ser realizada por un electricista de acuerdo con los últimos códigos y regulaciones.

 

Atenção: 

A instalação deve ser realizada por um eletricista de acordo com os códigos e regulamentos mais recentes.

 

Внимание

установка должна выполняться электриком в соответствии с последними нормами и правилами

.

 

Attention

: Disconnect from power source before installation or service to prevent electric shock 

 

Attention

: Débranchez

-

le de la source d'alimentation avant l'installation ou l'entretien pour éviter tout choc électrique.

 

Achtung

: Vor Installation oder Wartung von der Stromquelle trennen, um einen Stromschlag zu vermeiden.

 

Attenzione

: scollegare dall'alimentazione prima dell'installazione o dell'assistenza per evitare scosse elettriche.

 

Atención

: desconéctelo de la fuente de alimentación antes de la instalación o el servicio para evitar descargas eléctricas.

 

Atenção: 

Desconecte da fonte de alimentação antes da instalação ou serviço para evitar choque elétrico 

 

Внимание

отключите от источника питания перед установкой или обслуживанием

чтобы предотвратить поражение электрическим током

.

 

AC: 1.0 –

 

2.5mm

/ AWG18 –

 

AWG12

 

DC: 0.2 –

 

2.5mm

/ AWG24 –

 

AWG12

 

Summary of Contents for AlertAlight AL121H

Page 1: ...r gemäß den neuesten Vorschriften und Bestimmungen durchgeführt werden Attenzione L installazione deve essere eseguita da un elettricista in conformità con i codici e le normative più recenti Atención La instalación debe ser realizada por un electricista de acuerdo con los últimos códigos y regulaciones Atenção A instalação deve ser realizada por um eletricista de acordo com os códigos e regulamen...

Page 2: ...ton London W3 7QH sales e2s com e2s com D221 00 351 IS Issue 3 09 08 2021 P2 P3 P2 P3 Default S2 Tone 1 Default S1 Tone 44 ON 1 OFF 0 AC DC See D221 95 001 L N E C S2 S3 S2 S1 AC DC See D221 06 305 L N E E N L S1 S2 S3 S2 S1 DC See D221 06 301 E L N E ...

Page 3: ...L AL121H AlertAlight Combined Sounder LED E2S Warning Signals Impress House Mansell Road Acton London W3 7QH sales e2s com e2s com D221 00 351 IS Issue 3 09 08 2021 6x 1Nm ø20mm 209 47 8 25in 35 92 1 41in 35 92 1 41in 61 2 40in ...

Page 4: ... C 40 F to 131 F AL121NHAC 40 C to 40 C 40 F to 104 F To maintain Ingress Protection cable entries must be fitted with suitably rated cable glands or stopping plugs EOL Monitoring DC Only End of Line Devices may be fitted between the ve ve terminals of the PCBA Please ensure that the device legs meet the wire size range stated for the connection terminals and are fitted correctly in order to avoid...

Page 5: ...Page left Intentionally blank ...

Page 6: ... limitations on orientation Factory finishes are not intended to be modified Attention Installation must be carried out by an electrician in compliance with the National Electrical Code NFPA 70 and the National Fire Alarm Signaling Code NFPA 72 or CSA 22 1 Canadian Electrical Code Part I Safety Standard for Electrical Installations Section 32 L installation doit exclusivement être réalisée par du ...

Page 7: ... 27 6 dB A 180 97 8 dB A 0 95 8 dB A 180 96 8 dB A 0 95 9 dB A Jumper Setting Jumper Link 4 Jumper Link 5 Jumper Link 6 24VDC Mode Default Open Closed Open 12VDC Mode Customer Set Closed Open Closed AL121HDC024 Beacon PCBA 24VDC Mode Default Setting AL121HDC024 Beacon PCBA 12VDC Mode Customer to Set S2 S3 S2 S1 P2 P3 AL121HDC024 Sounder PCBA Flash Mode DIP switch E E Flash Mode DIP switch E E Jump...

Page 8: ...ve OUT Common ve IN Common ve OUT Stage 2 ve Stage 1 ve IN Stage 1 ve OUT Common ve IN Common ve OUT Stage 2 ve Stage 3 ve WIRING LINKING BEACON SOUNDER FACTORY FITTED 6 R1 R1 S2 S3 R1 S2 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED 14V MAX SYSTEM 120Ω MIN 2W MIN OR 1KΩ MIN 0 5W MIN 28V MAX SYSTEM 470Ω MIN 2W MIN OR 2 4KΩ MIN 0 5W MIN RECOMMENDED MINIMUM VALUES R1 Stage 1 ve IN Stage 1 ve O...

Page 9: ...TED D221 06 251 AL112NH AL121H DC COMBINED SOUNDER LED WIRING DIAGRAMS 6 S2 S3 R1 S2 R2 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED 14V MAX SYSTEM 120Ω MIN 2W MIN OR 1KΩ MIN 0 5W MIN 28V MAX SYSTEM 470Ω MIN 2W MIN OR 2 4KΩ MIN 0 5W MIN RECOMMENDED MINIMUM VALUES R1 Three Four Stages Voltage Free 2nd 3rd 4th Stage Activation Configuration Config 2 Common Positive Customer Set H1 H2 to Negat...

Page 10: ...ONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B R S RAIT B ISARD R N POTTS NTS OF 3 SWITCHES FOR STAGE OPERATION CUSTOMER SUPPLIED D221 06 251 AL112NH AL121H DC COMBINED SOUNDER LED WIRING DIAGRAMS 6 WIRING LINKING BEACON SOUNDER FACTORY FITTED OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED 14V MAX SYSTEM 120Ω MIN 2W MIN OR 1KΩ MIN 0 5W MIN 28V MAX SYSTEM 470Ω MIN 2W...

Page 11: ...ge 1 ve IN Stage 1 ve OUT Common ve IN Common ve OUT Stage 2 ve Stage 3 ve D221 06 251 AL112NH AL121H DC COMBINED SOUNDER LED WIRING DIAGRAMS 6 4 R1 R1 S2 R1 S2 S3 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED 14V MAX SYSTEM 120Ω MIN 2W MIN OR 1KΩ MIN 0 5W MIN 28V MAX SYSTEM 470Ω MIN 2W MIN OR 2 4KΩ MIN 0 5W MIN RECOMMENDED MINIMUM VALUES R1 Single Stage Configuration Config 5a Line Monitori...

Page 12: ...SOUNDER LED WIRING DIAGRAMS 6 5 S2 S3 R1 S2 R2 R1 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED 14V MAX SYSTEM 120Ω MIN 2W MIN OR 1KΩ MIN 0 5W MIN 28V MAX SYSTEM 470Ω MIN 2W MIN OR 2 4KΩ MIN 0 5W MIN RECOMMENDED MINIMUM VALUES R1 Three Four Stages Voltage Free 2nd 3rd 4th Stage Activation Configuration Config 6 Common Positive Customer Set H1 H2 to Negative Switching See Below Stage 1 Apply ...

Page 13: ... IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B R S RAIT B ISARD R N POTTS NTS OF SWITCHES FOR STAGE OPERATION CUSTOMER SUPPLIED D221 06 251 AL112NH AL121H DC COMBINED SOUNDER LED WIRING DIAGRAMS 6 6 OPTIONAL LINE MONITORING RESISTOR CUSTOMER SUPPLIED 14V MAX SYSTEM 120Ω MIN 2W MIN OR 1KΩ MIN 0 5W MIN 28V MAX SYSTEM 470Ω MIN 2W MIN OR 2 4KΩ MIN 0 5W MIN RECOMMENDED MINIMUM V...

Page 14: ...HEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D221 06 255 R S RAIT B ISARD R N POTTS OF A112NH AL121H AC COMBINED SOUNDER LED WIRING DIAGRAMS NTS 1 SWITCHES FOR STAGE OPERATION CUSTOMER SUPPLIED WIRING LINKING BEACON SOUNDER FACTORY FITTED 2 Stage 1 Live IN Stage 1 Live OUT Stage 1 Neutral IN Stage 1 Neutral OU...

Page 15: ... SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D221 06 255 R S RAIT B ISARD R N POTTS OF NTS 2 SWITCHES FOR STAGE OPERATION CUSTOMER SUPPLIED WIRING LINKING BEACON SOUNDER FACTORY FITTED 2 Earth Live IN Live OUT Neutral IN Neutral OUT Earth Stage 2 Stage 3 Common N N L L E N N L L E C S2 S3 Stage 1 Live IN Stage 1 Live OUT Stage 1 Neutral IN Stage 1 Neu...

Page 16: ... 0 0 0 1 0 1 0 0 0 0 1 1 0 0 0 1 1 1 0 0 0 0 0 0 1 0 0 1 0 0 1 0 0 0 1 0 1 0 0 1 1 0 1 0 0 0 0 1 1 0 0 1 0 1 1 0 0 0 1 1 1 0 0 1 1 1 1 0 0 0 0 0 0 1 0 1 0 0 0 1 0 0 1 0 0 1 0 1 1 0 0 1 0 0 0 1 0 1 0 1 0 1 0 1 0 0 1 1 0 1 0 1 1 1 0 1 0 1 1 0 1 1 0 0 0 1 1 1 0 0 1 1 1 1 0 0 0 0 0 0 1 0 1 0 0 0 1 1 1 0 0 0 1 0 0 1 0 0 1 1 0 1 0 0 1 0 1 1 0 0 1 1 1 1 0 0 1 0 0 0 1 0 1 0 1 0 1 0 1 1 0 1 1 0 1 0 1 1 1 0...

Reviews: