![e-survey E3L User Manual Download Page 72](http://html1.mh-extra.com/html/e-survey/e3l/e3l_user-manual_3147136072.webp)
SHANGHAI ESURVEY GNSS CO., LTD.
62
5.2.10.2.1 Set the Lead
To set the lead, do the following:
1. In
LEAD MEASURE
display, press
F1
/
1
. The following display shows:
2. Set the following:
o
New Lead
: a new lead name.
o
Lead Desc.
: lead description.
o
Meas Num
: the number of observation sets.
3. Press
PAGE
/
F4 SET
to go to the second page, and set the following:
o
First Stn
: the first survey station
o
Lead Bs Pt
: the lead backsight point
o
Start Brg
: the initial azimuth
4. Press
PAGE
/
F4 SET
to go to the third page, and set the following:
o
V_Obs_Tol
: the discrepancy tolerance of vertical angles among observation
sets.
o
Vindex Tol
: the discrepancy tolerance of vertical index error.
o
Hz_2c_Tol
: the discrepancy tolerance of horizontal collimation error C.
o
Hz_Obs_Tol
: the discrepancy tolerance of horizontal angles among
observation sets.