Manual SCA-LS-30-03
V 1.1
06/02 page 4
e-motion Gesellschaft für Antriebstechnik mbH, Zettachring 2, D-70567 Stuttgart, Germany
Tel.: +49-(0)711-7221535, Fax.: +49-(0)711-7221548 E-mail: [email protected]
3.1.3. + Tacho (5)
3.1.4. – Tacho (6)
For operating mode tacho control an analog tacho has to be connected to these inputs.
Input impedance:
50 kOhm
Maximum input voltage:
50 V
Important: at cw turning of motorshaft the potential of the Tacho has to be higher than the
potential of - Tacho to close the control loop.
Input connection tacho:
+Tacho
-Tacho
1k
33k
100k
33k
50k
100k
4k7
GNDA
3.1.5. + Vcc (3)
3.1.6. Power GND (4)
Power supply connector.
Caution: DO NOT c Vcc and Power GND to the o Motor or - Motor.
3.2. Outputs
3.2.1. Auxiliary voltage output V (13)
The auxiliary voltage output V provides a low-resistant connection to pin + Vcc (3).
+Vcc
V
1k
3.2.2. supervising report Error Out (11)
The error-signal is to show the status of the drive and can be used to provide a feedback signal to
other devices and controls. The open-collector is normally turned off which means the output is
pulled to a positive level by the means of an external resistor. In the case of a fault the output is
pulled to GND.
Input voltage range: max. 30 V DC
Load current:
< 20 mA
Output connection Error: