background image

Avoid exposing the phone to high temperature or below 0? or high humidity.

Avoid wetting the unit with any liquid.

Do not attempt to open it. Non-expert handling of the device could damage it. Consult your 

authorized dealer for help, or else it may cause fire, electric shock and breakdown.

Do not use harsh chemicals, cleaning solvents, or strong detergents to clean it. Wipe it with a 

soft cloth that has been slightly dampened in a mild soap and water solution.

In the event of lightning, do not touch power plug, it may cause an electric shock.

Do not install this phone in a poorly ventilated place. Before you work on any equipment, be 

aware of the hazards involved with electrical circuitry and be familiar with standard practices for 

preventing accidents.

Installation

Power Supply

The device supports two power supply modes: External power adapter and 802.3af Class 2 Power 
over Ethernet (PoE) compliant switch.

Using PoE the device can be powered through a single Ethernet cable which is also used for data 
transmission. By attaching a UPS system to the PoE switch, the device can continue to work during 
power outages.

If the device is connected to a PoE switch and power adapter at the same time, the power adapter will 
have priority and device will switch to PoE when there is a power failure on the power adapter. Please 
use the power adapter supplied and the PoE switch must meet the specifications to ensure a proper 
working device.

Connections

Connect the Infinity 2500 to PC, Network, Handset and Power adapter as per the diagram below.

Last modified: 10/15/18 07:19 AM

Copyright © 2015 E-MetroTel Global Inc.

Page: 3

Summary of Contents for Infinity 2500

Page 1: ...nd will support most application requirements in addition to its excellent call quality It provides powerful telephony features by combining the communications platform and features such as call trans...

Page 2: ...e package please check the home power voltage Inaccurate power voltage may cause fire and damage Please do not damage the power cord If power cord or plug is impaired do not use it it may cause fire o...

Page 3: ...h standard practices for preventing accidents Installation Power Supply The device supports two power supply modes External power adapter and 802 3af Class 2 Power over Ethernet PoE compliant switch U...

Page 4: ...The Infinity 2500 also has a USB port for charging external devices like mobile phones Infinity 2500 IP Phone Layout Last modified 10 15 18 07 19 AM Copyright 2015 E MetroTel Global Inc Page 4...

Page 5: ...o mute the microphone while on a call Press again to unmute Speaker LED Light is ON during hands free speaker mode Speaker key Press the speaker key for hands free mode Audio switches to the speaker H...

Page 6: ...dd an Extension for a Generic SIP Device with the following basic parameters User Extension e g 511 Display Name secret 4 If the device is connected to a UCx Cloud Server change the nat field to Yes O...

Page 7: ...password admin STEP TWO Configure SIP account Navigate to Line SIP page and perform the following steps 1 SIP Proxy Server Address field enter IP address of UCx Server 2 SIP Proxy Server Port field en...

Page 8: ...d click to expand the Advanced Settings section 8 Enter 97 for the Voice Message Number field 9 Click the Apply button to save the settings STEP THREE Configure DSS Keys Navigate to FUNCTION KEY page...

Page 9: ...Select from the drop down list Click the Apply button first before scrolling down the page to the other settings Scroll down the page and configure the Daylight Saving Time Settings Location Select fr...

Page 10: ...Last modified 10 15 18 07 19 AM Copyright 2015 E MetroTel Global Inc Page 10...

Reviews: