![E-MAG LYCOMING 200-6XL Series Installation And Operating Manual Download Page 5](http://html1.mh-extra.com/html/e-mag/lycoming-200-6xl-series/lycoming-200-6xl-series_installation-and-operating-manual_3109196005.webp)
4
V 200-6X.40 12/1/21
Engine performance mods (compression, induction, fuels, etc) might lower
your target MIN and MAX settings.
V 200-6X.41 4/25/23
Suggestion for long primary battery cable runs (RV10s, canards, others).
Clarify: Pull-Thru test verifies bank firing order only. Cannot be used to check
tracking accuracy.
Revised wiring schematic
Firmware V55 and after enables Fixed Mode starting, increased spark energy,
Fixed Mode fires at MIN vs previous version Fixed Mode firing at default 20.
Factory default MIN will be between 20 and 22 degrees.
FW V58 improves transitions from external power off to power on.
Manual sections have been reorganized to better follow installation flow.
Short-Cut
Abbreviated Overview
.
New installers should review the entire manual.
NOTE: Most Lycoming
™ styled engines rotate clockwise (viewed from back of the engine - looking
at prop on the far side). Series 200 6XL ignitions come pre-configured for this direction. If your
engine rotation is different (i.e. for a twin) you can easily change ignition direction (DIR). Confirm
proper DIR setting by watching the power-up Color-Burst. In the first ½ second the LED sequence
will end with a flash of WHITE followed by RED or GREEN, and then resume normal LED
signaling. Most Lycoming
™ styled engines will look for a White/RED Color-Burst (clockwise
rotation signal).
Prior to installation, make sure you have the following items identified and on-hand.
•
Suitable size ignition mounting studs and clamps
–
see Engine Attachment and Appendix 4
.
•
Fittings needed to connect ignition manifold pressure to your induction system
see Manifold
Pressure (MAP)
.
•
Identify your 14/28/48-volt power connection, fuse or circuit breaker, and power test switch
requirements
–
see Control Plug, Cockpit Controls, Wiring Diagram
.
•
Wire the Control Plug but
don’t
connect to ignition until instructed.
•
Suitable automotive spark plugs
– see Appendix 1
.
1)
Mount Ignition
: Insert the ignition(s) at any convenient orientation and tighten mounting clamps
to 17 ft/lb. Verify bus power and kill switches are both OFF, then connect the Control Plug.
2)
TC Setpoint
: -
see Setup
a) Move engine to flywheel TC mark. Press/hold the Config Button
while
you turn bus power
ON
–
Note 1
.
Continue hold
until LED turns BLUE - then release. LED will start blinking
BLUE/GREEN.
b) Press/hold Button again (for several seconds) until LED briefly flashes WHITE - release. TC
is now stored. Ignition will automatically reboot in normal mode and settle at YELLOW LED
with tone (i.e. TC position).
3)
Check or Change MIN and MAX
: Move prop to MIN and MAX positions
(see Note 2)
to
confirm or adjust as appropriate
(see Setpoints and Setup)
: