30
5.8 Temperature Control
Select
in the display (only possible, when remote unit F-411 is connected)
using „OK. The enclosure temperature range is from 5°C to 99°C and can be adjusted in
steps of 1°C by turning the Wheel Shuttle. If you press „OK“ while turning the Wheel Shuttle,
the step size is 10°C. Save the selected value by pressing „OK“. Factory presetting is 45°C.
Turn the Wheel Shuttle clockwise or counter-clockwise to continue the parametrization.
5.9 Function of F-411 Switch
Select
in the display (only possible, when remote unit F-411 is connected)
using „OK“. The actual function of the F-411 switch is the one in brackets. You can switch
over between <ON> and <OFF> by turning the Wheel Shuttle“. Confirm the selected function
by pressing „OK“. If you choose <OFF> the function of this switch is disabled.
Turn the Wheel Shuttle clockwise or counter-clockwise to continue the parametrization.
5.10 Pressure Regulation
Select
in the display using “OK“. You can change the factory setting of
“pulsed“ by turning the Wheel Shuttle. The values “two-point“ for use with the digital
controllers F-220.2 and F-220.2B and “pulsed“ for use with the digital controller F-220.3 are
available.
Confirm the selected type of pressure regulation with “OK“.
Turn the Wheel Shuttle clockwise or counter-clockwise to continue the parametrization.
5.11 Function Bypass
Select
in the display using „OK“. Enter the password after
by selecting each number with the Wheel Shuttle and confirming it with „OK“. Factory setting
is 5112.
The display shows the actual function of the bypass in brackets as shown above. Turn the
Wheel Shuttle to switch between <ON> and <OFF>. In the <ON> state the components
connected with the controller switch on immediately. The display stays in "FUNCTION
BYPASS <ON>" in order to avoid operation in the Ex area by mistake. In the <OFF> state
the display switches back to the start of the bypass menu after pressing "OK".
Turn the Wheel Shuttle clockwise or counter-clockwise to continue the parametrization.
PRESSURE
REGULATION
XXXXXXXXXX
FUNCTION
BYPASS
<ON> OFF
ENTER
PASSWORD
XXXX
TEMPERATURE
CONTROL
XX°C
FUNCT. ON/OFF
SWITCH F-411
<ON> OFF
8
9
10
11