24
5 Parametrizing the Controller
The Controller is programmed with the aid of the patented Wheel Shuttle
®
in the field “Menu“,
in conjunction with the button “OK/INFO“ on the front cover. Changes to the parametrization
can only be made with the aid of a suitable tool, e.g. a screwdriver.
MENU
INFO
OK
PE
L
L
N
K1
N
PE
Valve
EEx-p Control Unit F-351
T V 02 ATEX 1801
Ü
+(DC)-
IN
OUT
- +
Fig. 7: Front cover panel of the controller
5.0 Menus
5.0.1 Factory Settings
If you want to reset all values to the factory settings, please follow this procedure:
1. Separate the controller from the mains.
2. Switch the Wheel Shuttle to the „one o’clock“ position (one step clockwise from the
position shown in figure 7).
3. Keep the INFO button pressed, then connect the controller with the mains again.
4. Release the INFO button, as soon as „Load factory setting“ appears in the display.