WARNING
Warning identifies conditions and actions that pose hazards to the user.
To avoid electrical shock or personal injury, follow these guidelines:
Do not point laser directly at eye or indirectly off reflective surfaces.
Replace the batteries as soon as the empty battery indicator appears.
Do not operate the thermometer around explosive gas, vapour, or
dust.
Do not connect the optional external probe to live electrical circuits.
To avoid a burn hazard, remember that highly reflective objects will
result in lower than actual temperature measurements.
n
n
n
n
n
obstructing the unit’s optic. Make sure that the target is larger than the
unit’s spot size.
(MicroRay FOOD only)
The unit use the HI and the LO icons to display the HCCP Food Danger
Zone Alarm. The LO icon will appear if the temperature is below 4°C
(40°F); the HI icon will appear if the temperature is upper than 60°C
(140°F); The HI and LO icons will flash and the beeper will sound if the
temperature is inside the Danger Zone.
(MicroRay FOOD only)
The unit includes a programmable 8 hours countdown timer to help
monito cooking, cooling, and holding times.
All models (excluding PRO++) can store up to 64 test with date and time
using the internal real time clock. Datalogging can be manual or
automatic with settable sampling Time.
The optional Windows
IRLogman 2006 (see figure 3) software includes
the USB cable. The Software allows viewing, graphing, exporting and
printing the measure. Remove the USB Port cap (see fig.2) for PC
connecting.
(MicroRay +/AUTO++ only)
These instruments have a laser sighting with a reflex system of the beam
passing through the center of the lens, which grants the best possible
accuracy when aiming at a distance.
(MicroRay HVAC++ only)
It is possible to read the Air Temperature and Relative Umidity on the
display by selecting the external sensor function (see flow chart).
Danger Zone Alarm
8 Hours Countdown Timer
Memory
True Target Aiming (TTA)
Integrated T+RH% probe
TM
User Manual
MM850569 ed. 01
LASER RADIATION
DO NOT STARE INTO BEAM OR VIEW DIRECTLY
WITH OPTICAL INSTRUMENTS.
Max output: <1mW - Wavelength: 630-670nm
Class 2 laser product conforms to IEC825-1:1993.
Display
Buttons
Function Button
(see figure 4)
2 - Symbol for HOLD function
3 - External probe indicator
4 - Temperature value
5 - °C / °F engineering unit
6 - Symbol for HIGH alarm
7 - Symbol for LOW alarm
8 - Emissivity value
9, 10, 11 - MIN, MAX, Avg, and Dif 2nd line
value label
(see figure 5, 6)
If in measure mode, it cycles through the
memory manager menu;
If in Set mode, it decrease the value.
1 - Battery level indicator (3 levels)
12 - 2nd line value
13 - Laser on indicator
If the trigger is pulled the unit will switch on.
The laser will turn off and the display is HOLD
when he trigger is released. However, the
backlight remains on for 5 seconds. If no
button is pressed for 30 seconds the unit will
turn off.
If in Set mode, it accepts the parameter
change.
If in measure mode, it cycles through the
display mode menu;
If in Set mode, it increase the value.
Trigger
Mode Button
Maintenance
Changing the Battery
To remove the 9V battery, open the
battery compartment and pull the
bottom of battery
.
Extract the battery.
To install the battery, insert the
battery to the battery
with the positive side facing toward
the rear of the battery compartment.
(See figure 1)
compartment
Eurotron’s Warranty
Eurotron guarantees its products against defects in materials and
workmanship for 1 YEAR from the date of purchase. If the unit should
malfunction, it must be returned during the warranty period,
transportation prepaid, to any authorized Eurotron service center. Upon
examination, if the unit is found to be defective it will be repaired or
replaced at no charge. Eurotron's WARRANTY does not apply to defects
resulting from any action of the purchaser, including but not limited to
mishandling, improper interfacing, operation outside of design limits,
improper repair, or unauthorized modification. This WARRANTY is VOID if
the unit shows evidence of having been tampered with or shows evidence
of being damaged as a result of excessive corrosion; or current, heat,
moisture or vibration; improper specification; misapplication; misuse or
other operating conditions outside of Eurotron's control. This warranty
applies to the original purchaser only. Resellers are not authorized to
extend any other warranty on Eurotron’s behalf. The purchaser is
responsible for shipping charges, freight, insurance and proper packaging
to prevent breakage in transit. Please include a copy of the original
invoice.
CE Certification
This instrument conforms to the following standards:
EN 50081-1: 1992, Electromagnetic emissions
EN 50082-1: 1992, Electromagnetic immunity
Hand-Held Infrared
Non-Contact Thermometers
CAUTION
To avoid damaging the
thermometer or the
equipment under test protect
them from the following:
PROTECT FROM
THERMAL SHOCK
NO
PROTECT FROM EMF
& STATIC ELETTRICITY
NO
Auto Power Off: Automatic after 30 sec of no operation.
Alarm: low and high alarm with flashing label on display and sound.
Signal processing: °C/°F, hold, max, min, Dif. (max-min), Avg.
USB serial Port +Data Memory: 64 values including date/time (not
available on PRO++ model only)
Power supply: 9V alkaline battery
Typical battery life: 40 h with laser and backlight off
Ambient operating range: 0 to 50°C (32 to 120°F) / 10-95% RH non
condensing
Storage temperature: -20 to 60°C (-4 to 150°F) without battery
Tripod mount: ¼” 20 UNC threading
Environmental rating: IP54
Dimensions: 90x135x38 mm (3.5x5.5x1.5 in)
Weight: 165 g (6 oz.) net (battery included)
Sensor type: Pt1000 Class A - AISI316 (not included)
Sensor accuracy: ±(0.2% rdg. +0.2°C); ±(0.2% rdg. +0.4°F)
MicroRay Xtreme
MicroRay /+
MicroRay PRO++/HVAC++
MicroRay FOOD+/FOOD++
MicroRay AUTO+/AUTO++
Optics : D:S=35:1 (26mm@900mm, 1"@35") @90% of energy
Temperature Range: -30 to 760°C (-22 to 1400°F)
Accuracy : From 0 to f.s. (32 to f.s.) ±1% of reading or ±1°C (±1.8°F)
From -30 to 0°C (-22 to 32°F) ±(0.07°C/°C +1°C) ±(0.07°F/°F +1.8°F)
Optics : D:S=50:1 (18mm@900mm, 0.7"@35") @90% of energy
Temperature Range: -30 to 1000°C (-22 to 1832°F)
Accuracy : From 0 to f.s. (32 to f.s.) ±1% of reading or ±1°C (±1.8°F)
From -30 to 0°C (-22 to 32°F) ±(0.07°C/°C +1°C) ±(0.07°F/°F +1.8°F)
TTA sighting: (True Target Aiming) dot laser pinpointing (+ only)
s
"@40"
From 0 to 70°C (32 to 158°F) ±1°C (±1.8°F);
7
(158 to f.s.)
(±2.7°F)
From -30 to 0°C (-22 to 32°F) ±(0.07°C/°C +1°C) ±(0.07°F/°F +1.8°F)
Integrated ambient T+RH% sensor accuracy (HVAC++ only): ±2%RH ;
±0.2°C (±3.6°F)
Optics : D:S=12:1 (50mm@600mm, 2"@24") @90% of energy
Temperature Range: -30 to 300°C (-22 to 572°F)
Accuracy: From 0 to 100°C (32 to 212°F) ±1°C (±1.8°F);
From 100 to 300°C (212 to 572°F) ±1.5% of reading;
From -30 to 0°C (-22 to 32°F) ±1.5°C (2.7°F)
Danger Zone Alarm (from 4 to 60°C)
8 hours countdown timer
Optics : D:S=20:1 (50mm@1000mm, 2"@40") @90% of energy
Temperature Range: -30 to 760°C (-22 to 1400°F)
Accuracy : From 0 to f.s. (158 to f.s.) ±1% of reading or ±1°C (±1.8°F);
From -30 to 0°C (-22 to 32°F) ±(0.07°C/°C +1°C) ±(0.07°F/°F +1.8°F)
TTA Laser sighting: (True Target Aiming) dot laser pinpointing
Flashlight: White LED (AUTO+ only)
(-22 to 932°F)
/°F
/°F
/°F
Optic : D:S=20:1 (50mm@1000mm, 2
) @90% of energy
Temperature Range: -30 to 600°C (-22 to 1112°F)
Accuracy :
From
0 to f.s.
±1.5% of reading or ±1.5°C
(not available on AUTO+/AUTO++/HVAC++)
Input range: from -30°C to 500°C
Resolution: 0.1°C
up to 199.9°C
. 1°C
otherwise.
Accuracy: ±0.2% of reading or ±0.2°C (±0.36°F) whichever is greater
RTD Contact Probe
ENT
MOD
European Headquarter:
Eurotron Instruments SpA
Viale F.lli Casiraghi 409/413
20099 Sesto S. Giovanni (MI)
Tel. : 02 24 88 201
FAX: 02 24 40 286
Mail: [email protected]
Web: www.eurotron.com
USA Headquarter:
E Instruments Group LLC
172 Middletown Blvd - Suite B 201
Langhorne, PA 19047
Tel. : 215 750 1212
FAX: 215 750 1399
Mail: [email protected]
Web: www.einstrumentsgroup.com
MicroRay Xtreme//+
MicroRay PRO++ - MicroRay HVAC++
MicroRay FOOD+/FOOD++
MicroRay AUTO+/AUTO++
Distanza
Diam. Target
0
7
500
29
1000
50
3000
164
mm
mm
1500
79
Distanza
Diam. Target
0
0.3
19.7
1.1
40
2
78.7
4.2
in.
in.
59
3.1
100
11
4
0.4
D:S=20:1
50mm@1m
2in@40in
MicroRay PRO++
Distanza
Diam. Target
0
20
500
23
900
26
3000
133
mm
mm
1500
57
Distanza
Diam. Target
0
0.8
19.7
0.9
35
1
118
5.2
in.
in.
59.1
2.2
250
22
9.8
0.9
D:S=35:1
26mm@900mm
1in@35in
MicroRay Xtreme
Distanza
Diam. Target
0
20
500
19
1000
22
5000
191
mm
mm
1500
43
Distanza
Diam. Target
0
0.8
19.7
0.8
35
0.7
197
7.5
in.
in.
59
1.7
250
19
9.8
1.3
D:S=50:1
18mm@900mm
0.7in@35in
MicroRay
MicroRay +
FUN
2
Backlit
custom LCD
Laser Sight
Probe Jack
Battery
compartment
Wrist strap
Tripod thread
USB port
6
Mode button
MOD
Function button
FUN
5
Trigger
ENT
4
1
2
3
4
5
6
7
8
9
10
11
12
13
1
Technical Specifications
Spectral band: 8-14 mm
Repeatability: ±0.5% of the reading or ±0.7°C (±1.3°F)
Display resolution: 0.1°C/°F
Response time: 500 ms @ 95% response
Emissivity: pre-set to 0.95 - Adjustable from 0.20 to 1.00 - Value
indication on display.
Laser sighting: Wavelength 650nm, Beam diameter 3mm, Laser
indicator label on display
Display: 4 ½ digit custom back lighted LCD, 2nd line 5 digit
alphanumeric, plus labels for max, min, Dif., Avg, emissivity, Hold, °C,
°F, battery level, Ext. probe.
Measuring
Pull the trigger to switch the unit on. The display will show the
temperature and the laser will turn on. Move the laser pointer to the
centre of the measuring area. Read the temperature of the target. The
unit's display will remain activated (HOLD) for 30 seconds after the trigger
is released.
Important Notice
Inaccurate reading will result from measuring shiny or polished metal
surfaces. The unit cannot measure through transparent surfaces such as
glass. Steam, dust, smoke, etc. Can prevent accurate measurement by
3
IRLogMan 2006
Distance
Diam. Target
0
16
600
50
1000
94
2000
204
mm
mm
1500
149
Distance
Diam. Target
0
0.6
24
2
39
3.7
78.7
8
in.
in.
59
5.9
250
30
9.8
1.2
D:S=12:1
50mm@600mm
2in@24in
MicroRay FOOD+
MicroRay FOOD++