E Instruments Eurotron MicroRay Xtreme User Manual Download Page 1

WARNING

Warning identifies conditions and actions that pose hazards to the user.
To avoid electrical shock or personal injury, follow these guidelines:

Do not point laser directly at eye or indirectly off reflective surfaces.
Replace the batteries as soon as the empty battery indicator appears.
Do not operate the thermometer around explosive gas, vapour, or

dust.

Do not connect the optional external probe to live electrical circuits.
To avoid a burn hazard, remember that highly reflective objects will

result in lower than actual temperature measurements.

n

n

n

n

n

obstructing the unit’s optic. Make sure that the target is larger than the
unit’s spot size.

(MicroRay FOOD only)

The unit use the HI and the LO icons to display the HCCP Food Danger
Zone Alarm. The LO icon will appear if the temperature is below 4°C
(40°F); the HI icon will appear if the temperature is upper than 60°C
(140°F); The HI and LO icons will flash and the beeper will sound if the
temperature is inside the Danger Zone.

(MicroRay FOOD only)

The unit includes a programmable 8 hours countdown timer to help
monito cooking, cooling, and holding times.

All models (excluding PRO++) can store up to 64 test with date and time
using the internal real time clock. Datalogging can be manual or
automatic with settable sampling Time.
The optional Windows

IRLogman 2006 (see figure 3) software includes

the USB cable. The Software allows viewing, graphing, exporting and
printing the measure. Remove the USB Port cap (see fig.2) for PC
connecting.

(MicroRay +/AUTO++ only)

These instruments have a laser sighting with a reflex system of the beam
passing through the center of the lens, which grants the best possible
accuracy when aiming at a distance.

(MicroRay HVAC++ only)

It is possible to read the Air Temperature and Relative Umidity on the
display by selecting the external sensor function (see flow chart).

Danger Zone Alarm

8 Hours Countdown Timer

Memory

True Target Aiming (TTA)

Integrated T+RH% probe

TM

User Manual

MM850569 ed. 01

LASER RADIATION

DO NOT STARE INTO BEAM OR VIEW DIRECTLY
WITH OPTICAL INSTRUMENTS.

Max output: <1mW - Wavelength: 630-670nm
Class 2 laser product conforms to IEC825-1:1993.

Display

Buttons

Function Button

(see figure 4)

2 - Symbol for HOLD function
3 - External probe indicator
4 - Temperature value
5 - °C / °F engineering unit
6 - Symbol for HIGH alarm
7 - Symbol for LOW alarm
8 - Emissivity value
9, 10, 11 - MIN, MAX, Avg, and Dif 2nd line
value label

(see figure 5, 6)

If in measure mode, it cycles through the
memory manager menu;
If in Set mode, it decrease the value.

1 - Battery level indicator (3 levels)

12 - 2nd line value
13 - Laser on indicator

If the trigger is pulled the unit will switch on.
The laser will turn off and the display is HOLD
when he trigger is released. However, the
backlight remains on for 5 seconds. If no
button is pressed for 30 seconds the unit will
turn off.
If in Set mode, it accepts the parameter
change.

If in measure mode, it cycles through the
display mode menu;
If in Set mode, it increase the value.

Trigger

Mode Button

Maintenance
Changing the Battery

To remove the 9V battery, open the
battery compartment and pull the
bottom of battery

.

Extract the battery.
To install the battery, insert the
battery to the battery
with the positive side facing toward
the rear of the battery compartment.

(See figure 1)

compartment

Eurotron’s Warranty

Eurotron guarantees its products against defects in materials and
workmanship for 1 YEAR from the date of purchase. If the unit should
malfunction, it must be returned during the warranty period,
transportation prepaid, to any authorized Eurotron service center. Upon
examination, if the unit is found to be defective it will be repaired or
replaced at no charge. Eurotron's WARRANTY does not apply to defects
resulting from any action of the purchaser, including but not limited to
mishandling, improper interfacing, operation outside of design limits,
improper repair, or unauthorized modification. This WARRANTY is VOID if
the unit shows evidence of having been tampered with or shows evidence
of being damaged as a result of excessive corrosion; or current, heat,
moisture or vibration; improper specification; misapplication; misuse or
other operating conditions outside of Eurotron's control. This warranty
applies to the original purchaser only. Resellers are not authorized to
extend any other warranty on Eurotron’s behalf. The purchaser is
responsible for shipping charges, freight, insurance and proper packaging
to prevent breakage in transit. Please include a copy of the original
invoice.

CE Certification

This instrument conforms to the following standards:
EN 50081-1: 1992, Electromagnetic emissions
EN 50082-1: 1992, Electromagnetic immunity

Hand-Held Infrared
Non-Contact Thermometers

CAUTION

To avoid damaging the
thermometer or the
equipment under test protect
them from the following:

PROTECT FROM

THERMAL SHOCK

NO

PROTECT FROM EMF

& STATIC ELETTRICITY

NO

Auto Power Off: Automatic after 30 sec of no operation.
Alarm: low and high alarm with flashing label on display and sound.
Signal processing: °C/°F, hold, max, min, Dif. (max-min), Avg.
USB serial Port +Data Memory: 64 values including date/time (not
available on PRO++ model only)
Power supply: 9V alkaline battery
Typical battery life: 40 h with laser and backlight off
Ambient operating range: 0 to 50°C (32 to 120°F) / 10-95% RH non
condensing
Storage temperature: -20 to 60°C (-4 to 150°F) without battery
Tripod mount: ¼” 20 UNC threading
Environmental rating: IP54
Dimensions: 90x135x38 mm (3.5x5.5x1.5 in)
Weight: 165 g (6 oz.) net (battery included)

Sensor type: Pt1000 Class A - AISI316 (not included)
Sensor accuracy: ±(0.2% rdg. +0.2°C); ±(0.2% rdg. +0.4°F)

MicroRay Xtreme

MicroRay /+

MicroRay PRO++/HVAC++

MicroRay FOOD+/FOOD++

MicroRay AUTO+/AUTO++

Optics : D:S=35:1 (26mm@900mm, 1"@35") @90% of energy
Temperature Range: -30 to 760°C (-22 to 1400°F)
Accuracy : From 0 to f.s. (32 to f.s.) ±1% of reading or ±1°C (±1.8°F)
From -30 to 0°C (-22 to 32°F) ±(0.07°C/°C +1°C) ±(0.07°F/°F +1.8°F)

Optics : D:S=50:1 (18mm@900mm, 0.7"@35") @90% of energy
Temperature Range: -30 to 1000°C (-22 to 1832°F)
Accuracy : From 0 to f.s. (32 to f.s.) ±1% of reading or ±1°C (±1.8°F)
From -30 to 0°C (-22 to 32°F) ±(0.07°C/°C +1°C) ±(0.07°F/°F +1.8°F)
TTA sighting: (True Target Aiming) dot laser pinpointing (+ only)

s

"@40"

From 0 to 70°C (32 to 158°F) ±1°C (±1.8°F);

7

(158 to f.s.)

(±2.7°F)

From -30 to 0°C (-22 to 32°F) ±(0.07°C/°C +1°C) ±(0.07°F/°F +1.8°F)
Integrated ambient T+RH% sensor accuracy (HVAC++ only): ±2%RH ;
±0.2°C (±3.6°F)

Optics : D:S=12:1 (50mm@600mm, 2"@24") @90% of energy
Temperature Range: -30 to 300°C (-22 to 572°F)
Accuracy: From 0 to 100°C (32 to 212°F) ±1°C (±1.8°F);
From 100 to 300°C (212 to 572°F) ±1.5% of reading;
From -30 to 0°C (-22 to 32°F) ±1.5°C (2.7°F)
Danger Zone Alarm (from 4 to 60°C)
8 hours countdown timer

Optics : D:S=20:1 (50mm@1000mm, 2"@40") @90% of energy
Temperature Range: -30 to 760°C (-22 to 1400°F)
Accuracy : From 0 to f.s. (158 to f.s.) ±1% of reading or ±1°C (±1.8°F);
From -30 to 0°C (-22 to 32°F) ±(0.07°C/°C +1°C) ±(0.07°F/°F +1.8°F)
TTA Laser sighting: (True Target Aiming) dot laser pinpointing
Flashlight: White LED (AUTO+ only)

(-22 to 932°F)

/°F

/°F

/°F

Optic : D:S=20:1 (50mm@1000mm, 2

) @90% of energy

Temperature Range: -30 to 600°C (-22 to 1112°F)
Accuracy :
From

0 to f.s.

±1.5% of reading or ±1.5°C

(not available on AUTO+/AUTO++/HVAC++)

Input range: from -30°C to 500°C
Resolution: 0.1°C

up to 199.9°C

. 1°C

otherwise.

Accuracy: ±0.2% of reading or ±0.2°C (±0.36°F) whichever is greater

RTD Contact Probe

ENT

MOD

European Headquarter:
Eurotron Instruments SpA

Viale F.lli Casiraghi 409/413
20099 Sesto S. Giovanni (MI)
Tel. : 02 24 88 201
FAX: 02 24 40 286
Mail: [email protected]
Web: www.eurotron.com

USA Headquarter:
E Instruments Group LLC

172 Middletown Blvd - Suite B 201
Langhorne, PA 19047
Tel. : 215 750 1212
FAX: 215 750 1399
Mail: [email protected]
Web: www.einstrumentsgroup.com

MicroRay Xtreme//+

MicroRay PRO++ - MicroRay HVAC++

MicroRay FOOD+/FOOD++

MicroRay AUTO+/AUTO++

Distanza
Diam. Target

0
7

500

29

1000

50

3000

164

mm
mm

1500

79

Distanza
Diam. Target

0

0.3

19.7

1.1

40

2

78.7

4.2

in.
in.

59

3.1

100

11

4

0.4

D:S=20:1

50mm@1m

2in@40in

MicroRay PRO++

Distanza
Diam. Target

0

20

500

23

900

26

3000

133

mm
mm

1500

57

Distanza
Diam. Target

0

0.8

19.7

0.9

35

1

118

5.2

in.
in.

59.1

2.2

250

22

9.8
0.9

D:S=35:1

26mm@900mm

1in@35in

MicroRay Xtreme

Distanza
Diam. Target

0

20

500

19

1000

22

5000

191

mm
mm

1500

43

Distanza
Diam. Target

0

0.8

19.7

0.8

35

0.7

197

7.5

in.
in.

59

1.7

250

19

9.8
1.3

D:S=50:1

18mm@900mm

0.7in@35in

MicroRay 

MicroRay +

FUN

2

Backlit
custom LCD

Laser Sight

Probe Jack

Battery
compartment

Wrist strap

Tripod thread

USB port

6

Mode button

MOD

Function button

FUN

5

Trigger

ENT

4

1

2

3

4

5

6

7

8

9

10

11

12

13

1

Technical Specifications

Spectral band: 8-14 mm
Repeatability: ±0.5% of the reading or ±0.7°C (±1.3°F)
Display resolution: 0.1°C/°F
Response time: 500 ms @ 95% response
Emissivity: pre-set to 0.95 - Adjustable from 0.20 to 1.00 - Value
indication on display.
Laser sighting: Wavelength 650nm, Beam diameter 3mm, Laser
indicator label on display
Display: 4 ½ digit custom back lighted LCD, 2nd line 5 digit
alphanumeric, plus labels for max, min, Dif., Avg, emissivity, Hold, °C,
°F, battery level, Ext. probe.

Measuring

Pull the trigger to switch the unit on. The display will show the
temperature and the laser will turn on. Move the laser pointer to the
centre of the measuring area. Read the temperature of the target. The
unit's display will remain activated (HOLD) for 30 seconds after the trigger
is released.

Important Notice

Inaccurate reading will result from measuring shiny or polished metal
surfaces. The unit cannot measure through transparent surfaces such as
glass. Steam, dust, smoke, etc. Can prevent accurate measurement by

3

IRLogMan 2006

Distance
Diam. Target

0

16

600

50

1000

94

2000

204

mm
mm

1500

149

Distance
Diam. Target

0

0.6

24

2

39

3.7

78.7

8

in.
in.

59

5.9

250

30

9.8
1.2

D:S=12:1

50mm@600mm

2in@24in

MicroRay FOOD+

MicroRay FOOD++