6-8
Viking VM600 Mobile Radio Operating Manual
Conventional Features
6.9
Emergency Alarm and Call
Emergency Alarms and Calls are separate functions that can be individually enabled or
disabled on each analog and P25 conventional system. The Emergency option switch (or
menu selection) is required for these functions. Emergency Alarms and Calls are
transmitted on the global (radio wide) emergency zone/channel if one is programmed and
a smart console with message receiving capabilities is used. If it is not programmed, the
emergency is transmitted on the selected channel. The emergency programming of the
system to which that channel is linked controls the emergency operation.
6.9.1
Emergency Alarms
An emergency alarm is a special transmission that alerts a dispatcher of an emergency
situation. It is sent automatically by pressing Emergency option switch. The system to
which the emergency channel is linked must have Emergency Alarms enabled. If it does
not, Emergency Alarms are disabled. Emergency alarms and calls can be received on
smart consoles with message receiving capabilities.
In the P25 conventional mode, a special P25 emergency data transmission is sent, and in
the conventional analog mode, an DTMF emergency ID is sent. Refer to Section 6.12.3 for
information on the MDC1200 Emergency Alert.
Proceed as follows to send an emergency alarm:
1
If required, select a channel of a system on which Emergency Alarms are enabled and
then press the EMER option switch. The radio then automatically transmits the
emergency alarm.
2
Either Normal or Silent operation can be programmed. With the Normal mode, the red
LED lights, the emergency tone sounds, and “EMERGNCY” flashes in the display.
This indication continues to flash until the alarm mode is ended (see Step 4).
If silent programmed, none of these indications occur. If “No Receive Activity During
Emergency” is programmed, receive audio, the front panel LED, and receive icons are
disabled in the receive mode.
3
When the emergency alarm is acknowledged by the dispatcher, “ACK RCVD” is
briefly displayed and the emergency acknowledge tone (two beeps) sounds. This alert
tone can be disabled if desired, and neither occur if Silent operation is programmed.
Retries will automatically occur for conventional analog until the retry counter
completes.
4
The emergency alarm mode is exited when radio power is cycled or by pressing and
holding the Emergency option switch.
Draft 4/29/2014
Summary of Contents for Viking VM600 Series
Page 10: ...viii Viking VM600 Mobile Radio Operating Manual Table of Contents continued Draft 4 29 2014 ...
Page 20: ...xviii Viking VM600 Mobile Radio Operating Manual Safety Information Draft 4 29 2014 ...
Page 108: ...6 32 Viking VM600 Mobile Radio Operating Manual Conventional Features Draft 4 29 2014 ...
Page 188: ...Index 4 Viking VM600 Mobile Radio Operating Manual Index continued Zones 4 16 Draft 4 29 2014 ...