36

SMARTNET/SMARTZONE/P25 TRUNKED FEATURES

NOTE: The channel spacing is not set with P25 chan-
nels because it is always narrow, and the squelch 
cannot be changed because the setting is critical for 
proper receiver operation.

TG ID (P25 Only) -

 Selects the talk group for the 

selected channel. Press the Up/Down switch to display 
the alias of each preprogrammed talk group and then 
store it by pressing the F2 switch.

SECTION 6   SMARTNET/SMARTZONE/P25 TRUNKED FEATURES

6.1 INTRODUCTION

An overview of the SMARTNET/SmartZone and 

P25 Trunked operating modes is located in Section 
3.8. The following information describes the features 
unique to these modes of operation. Refer to the 
“Radio Wide Features” section starting on page 18 for 
information on features common to all operating 
modes.

6.2 ANALOG AND DIGITAL OPERATION

Either analog or digital operation can be selected 

for communication on SMARTNET traffic channels. 
Each talk group can be programmed for either type of 
operation. Digital operation may be an optional 
feature.

6.3 VIEWING UNIT ID

When power is turned on with a SMARTNET/

SmartZone channel selected, the five-digit Unit ID 
from 1-65,535 is briefly displayed as IDxxxxx. When 
a P25 channel is selected, the eight-digit unit ID from 
1-16,777,216 is briefly displayed (see Section 5.16.1).

6.4 STANDARD GROUP CALLS

6.4.1  INTRODUCTION

Standard group calls may be placed to another 

mobile, group of mobiles, or a dispatcher, depending 
on programming. Most calls are probably this type. 
Proceed as follows to place and receive group calls: 

6.4.2  PLACING A STANDARD GROUP CALL

1. Turn power on and set the volume as described in 

Section 3.1. Select the channel programmed for the 
talk group you want to call (see Section 3.3). 

2. If the talk group is programmed for encryption and 

is not strapped to Clear or Coded, select the desired 
mode by pressing the Clear/Secure option switch or 
selecting that menu parameter. The status cannot be 
changed if the talk group is strapped to Clear or 
Coded. Refer to Section 8.1.7 for more information.

3. Press the PTT switch and begin talking. An optional 

talk permit tone may sound to indicate when talking 
can begin. Events that may occur are as follows:

If in the secure mode and your transceiver is not 
programmed with the proper encryption key, 
“KEYFAIL” is displayed and the call must be 
made in the clear mode or the proper key must be 
programmed.

If the busy tone sounds and “BUSY” is displayed, 
the system is busy. Release the PTT switch and 
wait for the call back tone to sound. Then press 
the PTT switch within 3 seconds.

If a continuous tone sounds and “NO SYS” is 
displayed, you may be out-of-range. Drive closer 
or away from shielding objects and try again.

If your unit ID is invalid, the call is being made to 
an invalid group ID, or group calls are not 
enabled, “DISABLED ID” is displayed and an 
alert tone sounds.

If an attempt is made to change an analog call 
from the clear to secure mode and there is no 
available secure channel, “NO SEC” is flashed, 
an error tone sounds, and the call is terminated.

If an attempt is made to change an analog channel 
from the secure to clear mode, “SEC ONLY” is 
displayed, an error tone sounds, and the call is 
terminated. (Calls on digital channels can be 
changed if not strapped to clear or secure.)

Summary of Contents for 5100 SERIES

Page 1: ...64 360 Herndon Parkway FCC ID ATH2425111 Suite 1400 Model 242 51xx Herndon VA 20170 Standards FCC Part 90 IC RSS 119 http www rheintech com Date November 4 2004 Page 53 of 78 APPENDIX K USER S MANUAL Please refer to the Operator s Manual ...

Page 2: ...PORTABLE RADIO OPERATING MANUAL 5100 SERIES PORTABLE RADIO VHF UHF 700 and 800 MHZ PROJECT 25 CONVENTIONAL SMARTNET SMARTZONE 7 2 VDC 1 and 5 Watts VHF 1 and 4 Watts UHF 1 and 3 Watts 700 800 MHz Part No 242 51xx xxx ...

Page 3: ...xposure and provide simple procedures on how to control it Please refer to the following websites for more information on what RF energy exposure is and how to control your expo sure to assure compliance with established RF expo sure limits http www fcc gov oet rfsafety rf faqs html http www osha gov SLTC radiofrequencyradiation index html FEDERAL COMMUNICATIONS COMMISSION REGULATIONS The FCC rule...

Page 4: ... distance is important because RF exposures decrease with distance from the antenna Antenna should be kept away from eyes When worn on the body always place the radio in an EFJohnson approved clip holder holster case or body harness for this product Using approved body worn accessories is important because the use of EFJohnson or other manufacturer s non approved accessories may result in exposure...

Page 5: ...re sensitive to RF energy such as aircraft hospitals blasting sites and fuel storage sites Areas with potentially flam mable atmospheres are usually but not always clearly posted These may include gas stations fuel and chem ical storage and transfer stations below deck on boats and areas where the air contains flammable chemicals or particles such as grain dust or metal powders BATTERY DISPOSAL Di...

Page 6: ...emarks of the EFJohnson Company SMARTNET SmartZone SecureNet Call Alert Enhanced Pri vate Conversation and Private Conversation II are trademarks of Motorola Inc All other company and or product names used in this manual are trademarks and or registered trade marks of their respective manufacturer The IMBE voice coding technology embodied in this product is protected by intellectual property right...

Page 7: ...smitting in the Scan Mode 22 Nuisance Channel Add Delete 22 4 9 Scan Lists 22 Standard Mode Scan Lists 22 Radio Wide Scan List 22 Determining Which Channels are in Scan List 23 Selecting a Scan List 23 Editing a Scan List 23 5 CONVENTIONAL MODE FEATURES 5 1 Introduction 24 5 2 Monitoring Before Transmitting 24 5 3 Monitor Mode 24 5 4 Busy Channel Lockout 25 5 5 Call Guard Squelch 25 Introduction 2...

Page 8: ...ing a Telephone Call 39 Answering a Telephone Call 40 6 7 Call Alert 40 General 40 Answering a Page 40 Initiating a Page 41 6 8 Messaging 41 6 9 Sending Status Conditions 41 6 10 Emergency Alarm and Call 41 Introduction 41 Emergency Alarms 42 Emergency Calls 42 6 11 Failsoft Operation 42 6 12 SMARTNET Smartzone P25 Trunked Scanning Features 42 General 42 Priority Talk Group Sampling 43 6 13 Dynami...

Page 9: ... analog or digital Up to 16 zones with 16 channels each 256 channels total are standard Up to 32 zones and 512 channels total are optional Large graphic display with backlight Up to 9 limited keypad or 21 DTMF keypad programmable option switches Menu mode Standard and radio wide scan modes Time out timer User selectable high and low power output Keypad lock to prevent accidental key presses Operat...

Page 10: ...lephone Calls Emergency alarms to alert a dispatcher of emergency conditions Emergency calls for high priority system access Failsoft operation on a predefined conventional channel if trunked system fails Priority group calls detected while listening to other group calls when scanning Call Alert send and receive pages Predefined messages up to 16 can be sent to a dispatcher Predefined status condi...

Page 11: ...a programmable option switch F3 F4 Programmable option switches DTMF Keypad The full keypad DTMF models include the 12 keys required to dial telephone and unit ID numbers Speaker The transceiver speaker is located near the bottom of the front panel When a speaker microphone is used it is automatically detected when the Opt Sel 1 line of the accessory connector is pulled low The logic then automati...

Page 12: ...essories such as a speaker microphone or earphone It is also used for connecting the computer when programming the transceiver 2 4 DISPLAY Figure 2 3 Graphical Display The front panel display is shown above Icons are typically shown in the upper part of the display and text messages in the lower part The default icons are as follows When the scan or the scan list edit mode is enabled indicates tha...

Page 13: ...e level is adjusted by the top panel volume control knob or by option buttons programmed for the Up Down volume function When the buttons are used the volume control function of the knob is disabled it is still used to switch power Volume buttons may be used instead of the knob for example if accidental turning of the volume knob occurs When the volume control buttons are used the number of steps ...

Page 14: ... zone is displayed wrap around to the lowest programmed zone occurs and vice versa The selected zone is also displayed briefly on power up If the selected zone alias needs to be displayed continuously it must be programmed as part of the channel alias Channel Select Channels are selected by the rotary 16 position switch on the top panel The alias identification for the selected channel group is di...

Page 15: ...er if this switch is enabled by programming and rotated it selects the channel it is indicating For example if the switch index is pointing to channel 3 and channel 15 of the current zone is being displayed rotating it to channel 4 selects channel 4 of the current zone If the rotary Channel Select switch is enabled the radio always powers up on the channel it is selecting If it is disabled the rad...

Page 16: ... does not have a squelch control The squelch level is preset during alignment If the keypad programming feature is available see Section 5 17 the squelch level can be changed by the user on each conventional analog channel 3 8 TRANSCEIVER OPERATING MODES 3 8 1 GENERAL Each selectable channel can be programmed for the conventional analog or Project 25 digital SMARTNET SmartZone or Project 25 digita...

Page 17: ...channels are described in Section 6 3 8 4 P25 TRUNKED MODE The P25 Trunked operating features are very similar to the SmartZone type just described Since SmartZone features are also similar to SMARTNET features all three modes are described in the Section 6 Some differences between the P25 Trunking and SmartZone modes are as follows Digital signaling is always used with P25 calls Either analog or ...

Page 18: ...nnels and 4 SMARTNET channels One use of zones may be to program the channels used for operation in a different geographical areas The maximum number of zones is limited to 16 with stan dard models or to 32 with the 512 channel option SECTION 4 RADIO WIDE FEATURES 4 1 OPTION SWITCHES Almost all the buttons on this transceiver are programmable The programmable switches are as follows On the side pa...

Page 19: ...conventional chan nels a penalty time may also be programmed that prevents transmissions for a certain time after the transmitter is disabled see Section 5 6 One use of this feature is to prevent a channel from being kept busy for an extended period by an accidentally keyed transmitter It can also prevent possible transmitter damage caused by transmitting for an excessively long period 4 4 HOME ZO...

Page 20: ... 4 4 Key Select Key Select X 8 2 10 Keypad Lock Select Opt sw only X X X X 3 6 Keypad Programming Select Keypad Prg X 5 17 Messaging Message X X X 5 16 7 6 8 Monitor Mode Select Monitor X 5 3 Normal Selective Select Squelch X 5 5 OTAR Rekey Request OTAR Rekey X 8 2 10 Phone Call Select Phone X X 6 6 Priority Channel Select Priority X 5 11 3 Private Call Select Priv Call X X 6 5 Radio Wide Scan Sel...

Page 21: ...at are the same type as that currently selected For example if a conventional channel is selected only conventional channels are scanned and likewise for SMARTNET SmartZone and Project 25 Trunked channels More information on how standard scan ning operates in these modes is located in the following sections Conventional Mode Section 5 11 Other Modes Section 6 12 Standard scanning is turned on and ...

Page 22: ...other times occur on the selected channel 4 8 6 NUISANCE CHANNEL ADD DELETE With standard scanning channels can be tempo rarily deleted from the scan list for example if messages become annoying This feature is not avail able with radio wide scanning Channels can also be permanently added or deleted from a scan list as described in Section 4 9 5 Proceed as follows to temporarily delete a nuisance ...

Page 23: ...t list can also be selected if desired The programmed default scan list is automat ically reselected on power up Change the currently scan list as follows 1 With scanning disabled icon not displayed press the Scan List option switch or select the Scan Selct menu parameter 2 The currently selected list is displayed as List x where x is the currently selected list To exit without changing the select...

Page 24: ...el Monitoring If the selected channel is programmed for Busy Channel Lockout also called Transmit Disable On Busy monitoring is performed automatically Refer to Section 5 4 for more information on this feature Manual Channel Monitoring The automatic monitoring just described may occasionally disable the transmitter when the channel is not in use such as if the repeater has extended hang time In th...

Page 25: ...again 5 5 CALL GUARD SQUELCH 5 5 1 INTRODUCTION Tone or digital Call Guard squelch also called CTCSS DCS signaling can be programmed on each conventional analog transmit and receive channel in any order desired The reverse burst and turn off code are always transmitted and also detected on channels programmed with Call Guard squelch The Call Guard squelch feature eliminates distracting messages in...

Page 26: ...tion on Project 25 channels each position can be programmed with an NAC code When the Call Guard code is changed using this feature it remains selected even if other channels are selected However if transceiver power is cycled or a talk around channel is selected the normal codes are reselected When scanning the selected code also applies to all scanned channels If both analog and digital Project ...

Page 27: ... frequency is displayed when receiving and the transmit frequency is displayed when transmitting This feature is available on conventional channels only 5 10 EMERGENCY ALARM AND CALL NOTE The following enhanced conventional emer gency features require 5100 operating Flash soft ware 1 8 0 or later and PCConfigure 1 19 or later 5 10 1 INTRODUCTION Emergency Alarms and Calls are separate func tions t...

Page 28: ...ions 4 8 and 4 9 The following information describes features unique to conventional operation 5 11 2 TRANSMITTING IN SCAN MODE Each conventional scan list can be programmed for one of the following modes These modes deter mine if priority sampling occurs and also the channel on which transmissions occur while scanning Refer to the next section for more information on priority sampling No Priority...

Page 29: ...ity channel is checked for activity Times of 0 25 4 00 seconds in 0 25 second steps can be programmed Lookback Time B This time determines how often the priority channel is checked once an incorrect Call Guard CTCSS DCS or NAC code is detected Since it takes much longer to detect an incorrect Call Guard signal than a carrier this time should be relatively long to prevent the interruptions from mak...

Page 30: ...gramming software is not required This feature is available with 51xx portables only Other requirements are as follows The Clone menu parameter must be selectable by the master sending radio This parameter is not required with the slave receiving radio The master and slave radios must be identical models same frequency range and options Flash code Version 1 5 0 or higher is required with both radi...

Page 31: ...nalog channels NAC and group ID detect can be disabled by the monitor mode described in Section 5 3 5 16 4 P25 GROUP CALLS P25 group calls are placed by simply selecting the channel programmed for the desired group monitoring the channel if required and transmitting Changing a Channel Talk Group If the Digital Talk Group Select option switch or Select TG menu parameter is programmed the talk group...

Page 32: ...by programming or the channel is changed before a response is made the unit call mode is exited 5 16 6 CALL ALERT General The Call Alert feature allows pages to be sent and received on P25 conventional channels Opera tion is similar to SMARTNET SmartZone and P25 Trunked channels Answering a Page 1 When a page is received five beeps sound and PAGE is displayed The ID of the mobile paging you is sto...

Page 33: ...tified by an alias If the Status option switch or menu param eter is programmed status conditions are sent as follows 1 Momentarily press the Status option switch or select that menu parameter The alias of the current status condition is displayed 2 To change the current status press the Up Down switch until the desired status is displayed Then to send the status press the F2 Select switch or mome...

Page 34: ...s Edit Zone screen of the PCConfigure programmer This screen is displayed by clicking the Edit Zone button A different password can be programmed for each zone When an attempt is made to select a system or channel parameter in a password protected zone PASSWORD is flashed The password is always eight digits long and is entered using the same proce dure as used for the power up password described i...

Page 35: ... same as the preceding RX FREQ CTCSS DCS Squelch Control Analog Channel RX CODE Programs the receive Call Guard CTCSS DCS code The currently selected code and is initially displayed Press the Up Down switch to select the desired code type CTCSS analog or DCS digital Call Guard Then press F2 to select it and enter the code number similar to programming a channel frequency as just described TX CODE ...

Page 36: ...oup calls 6 4 2 PLACING A STANDARD GROUP CALL 1 Turn power on and set the volume as described in Section 3 1 Select the channel programmed for the talk group you want to call see Section 3 3 2 If the talk group is programmed for encryption and is not strapped to Clear or Coded select the desired mode by pressing the Clear Secure option switch or selecting that menu parameter The status cannot be c...

Page 37: ...ce between these call types is that the Enhanced type provides an indication that the called mobile is not on the air and the standard version does not Operation in each of these modes is described in the following information The Private Call option key is required to place these calls and either that key or the Call Response option key is required to receive them Private calls are programmed to ...

Page 38: ...vate Call option key or the F1 Exit key 6 5 3 PLACING A STANDARD PRIVATE CONVERSATION CALL Recalling From List 1 Momentarily press the Private Call option key or select that menu parameter The alias of the last called mobile is displayed and the private call mode is indicated by in the display 2 If required select another mobile by pressing the Up Down switch until the alias of the desired mobile ...

Page 39: ...ansceiver Telephone calls are programmed to operate in one of the following modes Disabled Answer only capability List only Telephone numbers can be selected from a preprogrammed list only direct entry using the keypad is not allowed Unlimited Telephone numbers can be selected from a list and also dialed directly entered using the keypad Both limited and DTMF keypad models can place telephone call...

Page 40: ...end it by pressing the Phone option key or F1 Exit key 6 6 3 ANSWERING A TELEPHONE CALL 1 When a telephone call is received ringing similar to a standard telephone is heard and PHONE is displayed 2 To answer the call press the Phone option switch or select that menu parameter and press the PTT switch to talk and release it to listen Since the transceiver operates half duplex it is not possible to ...

Page 41: ... desired message Then send the message by pressing the F2 key or momentarily pressing the PTT switch One of the following events then occurs If five beeps sound and ACK RECVD is displayed the message was received and automat ically acknowledged by the system If after five tries the message is not acknowledged a tone sounds and NO ACK is displayed 6 9 SENDING STATUS CONDITIONS The status feature al...

Page 42: ...el that has this feature enabled and press the Emergency option switch or select that menu parameter The emergency mode is indicated when ACK RCVD is briefly displayed and then EMERGNCY and the emergency talk group are alternately displayed 2 To place the emergency call manually press the PTT switch and begin speaking as with a standard call All group calls which follow are then emer gency calls p...

Page 43: ...f a locked regroup command is received the displayed talk group cannot be changed manually or by cycling power It can be changed only after a clear order is received from the console Dynamic regrouping operates as follows 1 When this command is received alternating tones sound and the transceiver automatically changes to the regrouping channel and DYN REGRP is displayed 2 Manually select the chann...

Page 44: ...it on the current site by pressing the Site Lock option switch or selecting that menu parameter The display then momentarily indicates the site alias to indicate that the current site is locked x is the current site number To unlock the site press the Site Lock switch again or the F2 Select key and UNLOCK is momentarily displayed SECTION 7 MISCELLANEOUS 7 1 SUPERVISORY TONES Single Beep Alert Tone...

Page 45: ...Configure programmer when the radio was set up not to any programming a user can perform If a feature is controlled by a front panel option switch and that switch is not available it is probably not available If the Keypad Programming option switch is available you can reprogram some conventional channel parameters Refer to Section 5 17 for more information 7 3 SPEAKING INTO MICROPHONE For best re...

Page 46: ...nstalled or an error in programming was detected Reprogram the radio If no characters appear in the display the battery may be discharged or defective Try another battery If some other problem is occurring turn power off and then on again to reset the control logic Also make sure that the controls are properly set If it still does not operate correctly return it for service NOTE There are no user ...

Page 47: ......

Reviews: