7.1
Start Up Failure LED Indications
Note
There are no user-serviceable components in the transceiver.
Table 7.1
Start Up Failure LED Indications
Orange LED
Blinks
Start Up Failure
Start Up Failure Type
1
Incorrect Software
The software was loaded on the wrong platform. This indication is displayed if the
boot loader version does not match the expected boot loader version number.
2
Bad File Format
The parameter file version number does not match the software version in the radio.
3
Parms Fail
The backup copy of the parameters (stored in the SPI flash device) is invalid. To
remove this error, use PC Configure to write the parameter file.
4
Bad Band
The radio band in the parameter file does not match the radio band in the tuning
parameters. This error message displays if a parameter file for the wrong band is
downloaded to the radio.
5
Corrupt Parms
This error message appears if the parameters checksum is OK, but the parameters
file has an error in it. This message does not normally appear.
6
EE PROM Fail
The self test timed out and the parameter file has not yet been read and verified.
7
DSP Failed
The PowerPC never received a power up message from the DSP.
8
Cycle Power
This error message appears when there is a communication failure between the
DSP and the back end ADC on the RF deck.