16-1
POWER TERMINATION MODULE (PTM)
SECTION 16 POWER TERMINATION MODULE (PTM)
16.1 DESCRIPTION
The Power Termination Module (PTM) provides
loading of the Data Communication Busses (DCB)
and PCM busses for each shelf. The PTM also
provides each shelf with fuse protection for supply
voltages.
16.2 SETUP PROCEDURE
Table 16-1 S5/S7 SWITCH TERMINATION
SETTINGS
S5 - IDB Data (37.5 ohms)
S7 - CSB Data (37.5 ohms)
Number of Shelves
Switch Sections Closed
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
ALL
1,3,6,7
1
2,4,5,6,7
2,5,6,7
2,7
3,4,5,6,7
3,4,6,7
3,4
3,5,6
3,5
3,6
3,7
3
4,5,6,7
4,5,6,7
4,5,6
4,5,7
4,5
4,5
4,6,7
4,6,7
4,6
Table 16-2 S6/S8 SWITCH TERMINATION
SETTINGS
S6 - IDB Idle (100 ohms)
S8 - CSB Idle (100 ohms)
Number of Shelves
Switch Sections Closed
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
8
4,5,7
1,2,6
5,6
2,5,6
1,3,6
6
2,3,4,5
1,2,4,5
4,5
1,2,4,5
1,4,5
1,2,5
1,2,5
2,5
5
5
1,2,3,4
1,2,3,4
1,2,3,4
3,4
3,4
Summary of Contents for 3000 SERIES
Page 2: ......
Page 12: ...TABLE OF CONTENTS viii TABLE OF CONTENTS CONT D This page intentionally left blank ...
Page 20: ...3000 SERIES SWITCH 2 6 This page intentionally left blank ...
Page 26: ...ARCHITECTURE 3 6 This page intentionally left blank ...
Page 58: ...CALL PROCESSOR 5 4 This page intentionally left blank ...
Page 76: ...BASIC BOARD MODULE BBM 7 14 This page intentionally left blank ...
Page 83: ...CHANNEL INTERFACE MODULE CIM 8 7 Figure 8 3 SUMMATION BOARD ALIGNMENT POINTS DIAGRAM ...
Page 84: ...CHANNEL INTERFACE MODULE CIM 8 8 This page intentionally left blank ...
Page 88: ...CONVENTIONAL CHANNEL MODULE CCM 9 12 This page intentionally left blank ...
Page 92: ...DISPATCH CHANNEL MODULE DCM 10 4 This page intentionally left blank ...
Page 100: ...DISPATCH INTERFACE MODULE DIM 11 8 This page intentionally left blank ...
Page 142: ...TELEPHONE INTERFACE MODULE TIM 14 32 This page intentionally left blank ...
Page 146: ...VOTER DIAGNOSTICS MODULE VDM 15 4 This page intentionally left blank ...
Page 156: ...VOICE TONE MODULE VTM 18 4 This page intentionally left blank ...
Page 164: ...WIDE AREA MODULE WAM 19 8 This page intentionally left blank ...
Page 174: ...CONVENTIONAL PATCH MODULE CPM 21 4 This page intentionally left blank ...
Page 178: ...POWER SUPPLY 22 4 Figure 22 6 POWER SUPPLY DRAWER ...
Page 196: ...INTERCOM 24 2 This page intentionally left blank ...
Page 200: ...ERROR MESSAGES A 4 This page intentionally left blank ...
Page 214: ...Part Number 001 3139 005 10 03 Printed in U S A ...