User Manual EE355 Dew Point Sensor

7.3  Spare Parts

Description

Order code

Stainless steel sintered filter

HA010103

8  Accessories

Description

Order code

Modbus configuration adapter

HA011013

E+E Product Configuration Software

 (Free download: www.epluse.com/configurator)

EE-PCS

Connection cable, 5 pole, M12x1 socket - free ends, PUR insulation 

 

1.5 m (4.9 ft) 

 

5 m (16.4 ft) 

 

10 m (32.8 ft)

HA010819 

HA010820 

HA010821

Sampling cell G 1/2" 

with quick connector

HA050102

Sampling cell NPT 

with bleed screw

HA050107

Sampling cell G 1/2" 

for atmospheric dew point

HA050106

Basic sampling cell G 1/2"

HA050103

Basic sampling cell NPT

HA050105

Please refer also to the “Accessories“ data sheet.

Summary of Contents for EE355

Page 1: ...BA_EE355 v1 4 Modification rights reserved User Manual EE355 Dew Point Sensor down to 60 C Td...

Page 2: ...equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmf...

Page 3: ...3 4 Auto calibration 7 3 5 Measuring Range and Accuracy 7 4 Installation 8 4 1 Installation Location 8 4 2 Installing directly into the Process 8 4 3 Installing the Sensor in a Sampling System 8 5 Set...

Page 4: ...ioning shall be performed by qualified personnel only Use the EE355 only as intended and observe all technical specifications Do not use EE355 in explosive atmosphere or for measurement of aggressive...

Page 5: ...protect them from accidental commissioning Mark the damaged product as defective A faulty device may only be investigated and possibly repaired by qualified trained and authorized staff If the fault...

Page 6: ...3 74 2 9 30 1 2 12 0 5 G1 2 1 2 NPT 92 3 6 34 5 1 36 89 3 5 AD27 AD22 Fig 1 EE355 Dimensions G ISO Thread in mm inch 140 5 5 77 3 74 2 9 30 1 2 12 0 5 G1 2 1 2 NPT 92 3 6 34 5 1 36 89 3 5 AD27 AD22 F...

Page 7: ...ed up to 5 times during the first hour of operation During auto calibration the analogue output can switch to one of two states Frozen output signal keeping the last measured value default behaviour o...

Page 8: ...ensor is protected by a cap that keeps the dew point sensor dry The cap should only be removed right before installation into the application Fig 4 Remove protection cap 4 2 Installing directly into t...

Page 9: ...ials give off moisture over time when flushed with very dry gas after being at ambient humidity 1 2 4 3 5 t h 70 60 50 40 30 20 Td C Fig 6 Moisture given off by different tubing materials National Phy...

Page 10: ...ction the power supply must be strong enough to ensure supply voltage within the specified range see technical data at any time and at all devices in the bus This is particularly relevant when using l...

Page 11: ...Unit US GB Unit Register number1 Dec Register address2 HEX Read register function code 0x03 0x04 State of auto calibration 0 normal operation 1 auto calibration active 501 0x1F4 Write register functio...

Page 12: ...ownload www epluse com configurator EE PCS Connection cable 5 pole M12x1 socket free ends PUR insulation 1 5 m 4 9 ft 5 m 16 4 ft 10 m 32 8 ft HA010819 HA010820 HA010821 Sampling cell G 1 2 with quick...

Page 13: ...inless steel 1 4404 AISI 316L IP65 NEMA 4 x Electrical connection M12x1 5 poles stainless steel 1 4404 Filter Stainless steel sintered Operating conditions 40 70 C 40 158 F 0 100 RH Storage conditions...

Page 14: ...lin 69130 Ecully Tel 33 4 74 72 35 82 E mail info epluse fr E E Elektronik Germany Sch ne Aussicht 8 C 61348 Bad Homburg Tel 49 6172 13881 0 E mail info epluse de E E Elektronik Italy Via Alghero 17 1...

Reviews: