Document:
Date
Created By:
ECO#
LPN00684X0001A0_A
3-9-2020
TMT
011592
INSTALLATION INSTRUCTIONS
E-WPS Series
www.e-conolight.com | 888.243.9445 | FAX: 262.504.5409
1.
Remove the mounting base from the fixture by loosening (do NOT
fully remove) the one or two (depending on fixture size) mounting
base screws on the bottom of the fixture and lifting the fixture off
the base. See
Figure 1.
2. Remove (4) knockouts from the corners of the mounting base to
allow for attachment of mounting base to mounting surface. See
Figure 2
for knockout locations.
3.
Position mounting base at desired fixture mounting location. Make
sure rib on outer edge of mounting base is facing upwards. Use
mounting base as template to mark hole locations on mounting
surface.
4. Drill holes at marked locations for attachment of mounting base to
mounting surface.
5. Attach mounting base to mounting surface with fasteners
appropriate for mounting surface (supplied by others).
NOTE:
The bubble level inside the mounting base should be used
to ensure a level install of fixture.
6. Remove the threaded 1/2" conduit entry plug from the chosen side
of the mounting base.
7. Feed the conduit and supply wires into chosen conduit entry
location.
8.
For hands free wiring, position the fixture housing on top of the
mounting base by inserting the rib on the mounting base into the
slot on the top of the fixture.
9. Make wiring connections per
Fixture Wiring
section.
10.
Lift fixture housing off mounting base and rotate housing so that
slot in fixture housing is facing upward.
11. Insert rib on upper edge of mounting base into slot on top of
fixture.
12.
Push lower edge of fixture against mounting base and tighten
one or two (depending on fixture size) mounting base screws on
the bottom of the fixture to retain the fixture against the mounting
base.
13. A high grade caulking material, such as silicone rubber, should
be used where the mounting base meets the mounting surface to
ensure a watertight seal. Make sure that caulk is applied around
the entire perimeter of the mounting base. See
Figure 4.
1.
Shut off power before cleaning the fixture. To prolong the original
appearance, clean the fixture with clean water and a soft, damp
cloth only.
2. Do NOT use abrasive cleaners or cleaners that contain alcohol.
Do NOT apply paints, solvents, or any other chemicals to the
light fixture because these substances could cause premature
deterioration of the finish.
3.
Do NOT spray the fixture with a high pressure washer.
SURFACE CONDUIT MOUNTING
FIGURE 3
FIGURE 4
CARE AND CLEANING
Mounting Base
1, 2, 3
4
5
6, 7
7
1 2
3
4, 5
6
Junction Box Mounting Guide
1
4 in. Square Box
5
4 in. Round Box
2
4 in. Octagonal Box
6
2-3/4 in. Hole Pattern
3
3-1/2 in. Square/Octagonal Box
7
Single Gang
4
Masonry Box
FIGURE 2
Mounting Screws
Bubble Level
Rib in Mounting Base
Mounting Base