background image

ELECTRIC CIRCUIT DIAGRAM

: BROWN

: BLUE

SY 

: YELLOW-GREEN

: WHITE

: PHASE

: NOTR

TOP  : GROUND

: THERMOSTAT

: RESISTANCE

PRODUCTION
EMAS MAKİNA SANAYİ A.Ş.

Ramazanoğlu Mah. Sanayi Cad. No:17 
34890 Pendik/İSTANBUL
Tel. : (0216) 378 34 00 - pbx
Fax: (0216) 378 20 59
email: [email protected]
www.emas.com.tr

SALES
EMAS MAKİNA SANAYİ A.Ş.

Yalı Mah. Ziya Gökalp Cd. No:3 34844
Maltepe/İSTANBUL
Tel.: (0216) 442 34 41
Fax: (0216) 442 39 96
e-mail: [email protected]
www.emas.com.tr

SERVICE
EMAR A.Ş. SERVİS MÜDÜRLÜĞÜ

Yalı Mah. Ziya Gökalp Cd. No:3 34844
Maltepe/İSTANBUL
Tel.: (0216) 458 45 00 (pbx)
Fax: (0216) 305 65 43
www.emas.com.tr

EMAS A.Ş. and EMAR A.Ş. ARE THE ORGANIZATIONS OF ELGİNKAN SOCIETY

v-AUTOMAT

(CIRCUIT BREAKER)

ELECTRIC TERMINAL

BOILER BODY

FLANGE

LIGHT

SWITCH

Top

F

N

SY

K

K

K

K

M

M

M

B

B

1
2

R

M

SY

ELECTRIC STORAGE

WATER HEATER

MANUAL OF 

MONTAGE,

USAGE,

MAINTENANCE

T-221 L / T-221 S
T-223 L / T-225 L

Summary of Contents for T-221 L

Page 1: ...lp Cd No 3 34844 Maltepe İSTANBUL Tel 0216 442 34 41 Fax 0216 442 39 96 e mail satis emas com tr www emas com tr SERVICE EMAR A Ş SERVİS MÜDÜRLÜĞÜ Yalı Mah Ziya Gökalp Cd No 3 34844 Maltepe İSTANBUL Tel 0216 458 45 00 pbx Fax 0216 305 65 43 www emas com tr EMAS A Ş and EMAR A Ş ARE THE ORGANIZATIONS OF ELGİNKAN SOCIETY v AUTOMAT CIRCUIT BREAKER ELECTRIC TERMINAL BOILER BODY FLANGE LIGHT SWITCH Top...

Page 2: ...C STORAGE WATER HEATER INSTALLATION CONNECTION CONTROL PANEL The inlet and outlet pipes for water in your heater are of R 1 2 Cold Water Inlet Connect the blue pipe to the cold water installation after assembling the security valve Hot Water Inlet Connect the red pipe to the hot water installation It must be ensured that the pipe connections do not leak water ON OFF SWITCH With the ON OFF switch o...

Page 3: ...rity thermostat is connected to the electric circuit If the water temperature rises excessively certain security is ensured by turning off the heating resistance SECURITY VALVE The security is mounted at the cold water inlet and has two different functions 1 During water cuts it shall act as a non re turn valve and keep the water in the boiler 2 If the internal pressure of the boiler rises it bala...

Page 4: ...x 8 9 bar Class I IPx1 1265mm 400mm 400mm 42kg 45kg MODEL T 223 L T 221 L T 225 L MEASUREMENTS WEIGHT E C A T 221 S model differs from T 221 L model in that in the standard ESWH there is not an ON OFF switch PROPERTIES OF E C A ELECTRIC STORAGE WATER HEATER E C A ESWH is a modern and easy water heater and has these properties which ensure the traditional E C A quality SECURITY OF USE ON OFF SWITCH...