31
Rev. 0.6
[email protected] • www.e-breathe.de
e-breathe e-Flow
2.2 Filter
The choice of filter depends, among other things, on the type of contamination and the concentration. The blower
can be used either with only two particle filters, two gas filters or with two combination filters (combination of particle
and gas filter). (See separate instructions for use of the filters).
Typ
Color
Code
main application area
Class
Permitted maximum
gas concentration
A
brown
Protects against organic gases and vapours.
e.g. solvent with a boiling point above +65 °C
1
2
3
0,05 Vol-%
0,1 Vol-%
0,5 Vol-%
B
grey
Protects against inorganic gases and vapours.
e.g. chlorine, hydrogen sulphide and hydrocyanic acid
(not against CO)
1
2
3
0,05 Vol-%
0,1 Vol-%
0,5 Vol-%
E
yellow
Protects against acid gases and vapours.
e.g. sulphur dioxide and hydrogen fluoride
1
2
3
0,05 Vol-%
0,1 Vol-%
0,5 Vol-%
K
green
Protects against ammonia and certain amines.
e.g. ethylenediamine
1
2
3
0,05 Vol-%
0,1 Vol-%
0,5 Vol-%
HG
red
Protects against mercury vapour.
Warning! Maximum application time 50 hours.
1
2
3
Observe
manufacturer‘s ins-
tructions for use
The following filters are available for the e-breathe e-Flow with PAD-Box
Filter
can be combined with:
e-breathe ecoPAD P3 R / PSL
Gasfilter Adapter und ecoPAD GF A2, A2B2, ABEK
e-breathe ecoPAD GF A2
Filter Cover and ecoPAD P3 R / PSL
e-breathe ecoPAD GF A2B2
Filter Cover and ecoPAD P3 R / PSL
e-breathe ecoPAD GF A2B2E1K1
Filter Cover and ecoPAD P3 R / PSL
The following filters are available for the e-breathe e-Flow with filter box
Filter
can be combined with:
e-breathe Particle Filter P3 R / PSL
Gas Filter Adapter and ecoPAD GF A2, A2B2, ABEK
e-breathe Combination Filter A2-P3
ecoPAD P3 R / PSL and ecoPAD GF A2, A2B2, ABEK
e-breathe Combination Filter A2B2-P3
ecoPAD P3 R / PSL and ecoPAD GF A2, A2B2, ABEK
e-breathe Combination Filter A2B2E1K1-P3
ecoPAD P3 R / PSL and ecoPAD GF A2, A2B2, ABEK
Typ /
Class
Color
Code
main application area
P3
weiß
P = For use against solid and liquid toxic, radioactive and harmful particles as well as microorga-
nisms such as bacteria and viruses.
R
R (reusable) = The particle filter is intended for multiple use and can be used throughout several
working shifts.
SL
SL (Solid Liquid) = The particle filter is designed for use against solid and liquid aerosols.
Gas Filter A, B, E, K, HG
Particle Filter