background image

 

 

 

 

Instruction Manual

 

of H2F Mobile Phone 

Infrared Thermal Imager   

Version (V1.0)   

 

 

 

 

Summary of Contents for H2F

Page 1: ...Instruction Manual of H2F Mobile Phone Infrared Thermal Imager Version V1 0...

Page 2: ...Shenzhen Dianyang Technology Co Ltd which shall not be imitated copied or translated in any way without the permission of the Company This manual contains no warranty expression of position or other...

Page 3: ...5 3 1 Setting 8 5 3 2 About 9 5 3 3 Interface Reset 9 5 3 4 Photo Taking 10 5 3 5 Video Recording 11 5 3 6 Album 11 5 3 7 Color palette 12 5 3 8 Regional Temperature Measurement 14 5 3 9 Temperature T...

Page 4: ...all pixel spacing and high resolution ratio and is equipped with a 3 2mm lens The product is lightweight and portable and can be used directly when plugged in With the customized professional thermal...

Page 5: ...It supports high temperature alarm and customized alarm threshold It supports the display of user defined temperature range screen and has many use scenarios for the display of high temperature regio...

Page 6: ...perature measurement range 15 450 Temperature measurement accuracy 2 C or 2 of reading Temperature measurement Highest lowest central point and area temperature measurement are supported Color palette...

Page 7: ...5 4Appearance and Equipment Connection Hardware Appearance and Part Name Figure 4 1 0 1...

Page 8: ...and installation Note OTG connection is required to be enabled in the mobile phone settings to run the APP normally because its location varies from phone to phone you can search for OTG in the setti...

Page 9: ...ent color palette can be switched to change the color of the video Regional Temperature Measurement Points lines and boxes can be added to measure temperature in different regions Temperature Tracking...

Page 10: ...5 2 Figure 5 2 0 2See Table 2 for the description of each setting item in the panel Table 2 2 Figure 5 2 0 2 General items Language English Temperature unit The temperature units can be set with Celsi...

Page 11: ...easurement deviation Reflection temperature Parameter values shall be filled in according to the reflection temperature of the test environment Ambient temperature Parameter values shall be filled in...

Page 12: ...Taking button to take the current infrared screen and save it automatically The photo button will remain red for one second and the heat map window will have an animation that is drawn into the album...

Page 13: ...isplayed correspondingly in the lower left corner of the video window at the same time Click the Video Recording button again to stop video recording Figure 5 6 0 6 5 3 6 Album All photos and videos t...

Page 14: ...ime Photo Only photo files are displayed Video Only video files are displayed with the video duration in the preview image Trash can Files are selected and then deleted 5 3 7 Color Palette There are 6...

Page 15: ...ion which is suitable for users of black and white traditional mode Black heat The high temperature section adopts black and the full screen mainly adopts black and white transition which is suitable...

Page 16: ...ed which is suitable for scenarios focusing on the high temperature state Cold blue Blue is used to mark the colder regions which is more suitable for observing low temperature target objects By adjus...

Page 17: ...the following interface will pop up allowing the temperature measurement of points lines and rectangular boxes to be added to the video in which the lines and rectangular boxes will display the real t...

Page 18: ...le or disable the measurement of the maximum temperature minimum temperature and center point temperature in the real time screen Red is the maximum temperature blue is the minimum temperature and yel...

Page 19: ...n be highlighted If there is no rectangular box in the current screen a rectangular box will be automatically added in the default position By long pressing the rectangular box its size can be adjuste...

Page 20: ...hold value pops up on the interface as shown in the figure below When the maximum temperature value in the screen is higher than the alarm threshold value in the regional temperature measurement mode...

Page 21: ...r board and the other regions are displayed as white heat and the temperature range can be adjusted by the slider on the right side of the color board bar The analysis mode of highlighted high tempera...

Page 22: ...ergent and other organic cleaners to clean the lens It is recommended to wipe the lens with soft objects dipped in water 2 Do not let sunlight laser and other strong light sources directly illuminate...

Page 23: ...21 7 Packing List Name Quantity H2F host 1 set Lens cleaning cloth 1 pcs Cloth bag 1 pcs Instruction manual 1 pcs...

Page 24: ...5 to 0 80 Sand 0 9 Charcoal powder 0 96 Soil 0 92 to 0 96 Paint 0 80 to 0 95 Water 0 92 to 0 96 Paint matte 0 97 Ice 0 96 to 0 98 Rubber black 0 94 Snow 0 83 Plastic 0 85 to 0 95 Glass 0 90 to 0 95 Wo...