![Dynojet 24xLC2 Linx Installation Manual Download Page 41](http://html1.mh-extra.com/html/dynojet/24xlc2-linx/24xlc2-linx_installation-manual_2550663041.webp)
37
L I N X W I T H A T R A F L E X I N S T A L L A T I O N
Upper Pulley Mount Installation
Version 3
Linx with Atra Flex Installation for Model 424 Automotive Dynamometers
I
NSTALLING
THE
U
PPER
S
TATIONARY
D
YNO
P
ULLEY
M
OUNT
1
Place the upper stationary dyno pulley mount (P/N 61300022, stamped 1) over
the stationary dyno pulley and loosely secure the mount to the inner plate using
five 3/8-16 x 1-inch bolts and five 3/8-inch flat washers (one of the holes on the
pulley mount is not used).
2
Loosely secure the pulley mount to the stationary dyno pulley bearing plate using
five 3/8-16 x 1-inch bolts and five 3/8-inch flat washers.
3
While applying upward pressure to support the shaft and pulley, tighten all the
bolts.
4
Using the installation instructions in
, secure the cap screws.
Figure 30: Install the Pulley Mount Over the Stationary Dyno Pulley
pulley mount
P/N 61300022
stamped 1