HSP 600
HSP 1500
HSP 2600
HSP 4000
HSP 7000
HSP 10000
HSP 16000
06/18 re
v 1.2
HYDRAULIC SUBMERSIBLE PUMPS
USER MANUAL
Download PDF version from www.Dynaset.com/manuals Keycode: KL6SLG
Page 1: ...HSP 600 HSP 1500 HSP 2600 HSP 4000 HSP 7000 HSP 10000 HSP 16000 06 18 rev 1 2 HYDRAULIC SUBMERSIBLE PUMPS USER MANUAL Download PDF version from www Dynaset com manuals Keycode KL6SLG...
Page 2: ......
Page 3: ...u to take the full advance of the technical features avaible in your equipment Please contact us for any feedback you might have on our products Your feedback is important to us for improving our prod...
Page 4: ...LABELS 13 3 OPERATING PRINCIPLES 15 3 1 OPERATING DESCRIPTION 15 4 INSTALLATION 17 4 1 INSTALLATION TO A HYDRAULIC TOOL LINE 17 4 2 HYDRAULIC FLUIDS 19 4 3 CONNECTING HYDRAULIC HOSES 19 4 4 CONNECTING...
Page 5: ...Yl j rvi puh 03 3488 200 info dynaset com www dynaset com 7 MANUFACTURER S LIMITED WARRANTY 29 8 PRODUCT DISPOSAL 31 9 DECLARATION OF CONFORMITY 33 10 TECHNICAL SPECIFICATIONS 35 HYDRAULIC SUBMERSIBL...
Page 6: ...10 Picture 5 Operation description of HSP pump 15 Picture 6 Example of tool line installation 18 Picture 7 Connecting hydraulic hoses 19 Picture 8 Connecting the discharge line 20 Picture 9 Placing t...
Page 7: ...ndling operation and maintenance right from the beginning Pay attention to warnings and safety instructions READ CHAPTER 2 SAFETY for more information for more information 1 1 PRODUCT INFORMATION Dyna...
Page 8: ...oduce 3 Head of standard discharge The head in which the standard discharge of the HSP pumps are measured 4 Maximum hydraulic flow from the hydraulic system of base machine that HSP pump is designed t...
Page 9: ...3 33470 Yl j rvi puh 03 3488 200 info dynaset com www dynaset com HYDRAULIC SUBMERSIBLE PUMPS GENERAL 1 4 HSP PUMP LINE UP Picture 3 HSP pump line up 1 HSP 600 2 HSP 1500 3 HSP 2600 4 HSP 4000 7000 5...
Page 10: ...om www dynaset com HYDRAULIC SUBMERSIBLE PUMPS GENERAL 1 5 MAIN COMPONENTS OF HSP PUMP Picture 4 Main components of HSP pump 1 Pump body 2 Hydraulic motor 3 Impeller 4 Bottom plate intake 5 Screen 6 Q...
Page 11: ...injuries Always wear appropriate clothing and safety equipment Couplings valves and hoses need to be kept tight and clean to avoid possible leakages Leaks in the hydraulic system must be repaired imme...
Page 12: ...HSP pump beware of machinery parts warmed by hot hydraulic oil WARNING RISK OF BURNS The unit parts and hydraulic oil can be hotter than 80 C Wear personal safety equipment Never aim high pressure wa...
Page 13: ...onents of the system clean This is to ensure safe reliable and longlife operation of your equipment Hydraulic system of a base machine should be maintained according to the service program 2 5 WARNING...
Page 14: ...14 Dynaset Oy Menotie 3 33470 Yl j rvi puh 03 3488 200 info dynaset com www dynaset com HYDRAULIC SUBMERSIBLE PUMPS SAFETY...
Page 15: ...aulic motors are gear gerotor or piston type depending on pump Pump can run dry because motor seal is oil lubricated no water cooling required Picture 5 Operation description of HSP pump 1 The pump is...
Page 16: ...16 Dynaset Oy Menotie 3 33470 Yl j rvi puh 03 3488 200 info dynaset com www dynaset com HYDRAULIC SUBMERSIBLE PUMPS OPERATING PRINCIPLES...
Page 17: ...HSP pump can be operated from the existing controls Install the hydraulic tool lines pressure P and return T ports to their corresponding ports in the HSP pump Ensure that the hydraulic flow of the ba...
Page 18: ...UMPS INSTALLATION In the picture 6 is an example of installing the HSP pump into a existing tool line Picture 6 Example of tool line installation 1 DYNASET HSP pump 2 Quick couplers for hydraulic conn...
Page 19: ...information 4 3 CONNECTING HYDRAULIC HOSES Pressure P and return T lines of a hydraulic system are connected to the DYNASET unit s corresponding hydraulic ports Picture 7 Connecting hydraulic hoses Ro...
Page 20: ...m www dynaset com HYDRAULIC SUBMERSIBLE PUMPS INSTALLATION 4 4 CONNECTING THE DISCHARGE LINE Discharge hose is to be connected to the HSP pump with a quick coupling Ensure that there are no sharp bend...
Page 21: ...ouplings in hydraulic and pumping fluid circuits before use to ensure there are no leaks or damages HSP pump is ready to use unit Place the pump into the liquid to be pumped and the outlet end of the...
Page 22: ...rol valve Picture 10 Starting the HSP pump If the liquid contains too much inpurity to be pumped through the intake screen the screen can be detached 5 3 HEAD DIAGRAMS OF THE HSP PUMP Pump head is max...
Page 23: ...enotie 3 33470 Yl j rvi puh 03 3488 200 info dynaset com www dynaset com HYDRAULIC SUBMERSIBLE PUMPS OPERATION 5000 10000 15000 20000 5 10 15 20 25 30 25000 DELIVERY l min 0 35 HEAD m 0 HSP16000 5 317...
Page 24: ...OPERATION 5 4 STOPPING THE HSP PUMP When pumping is completed the HSP pump can be stopped by closing the hydraulic control valve Picture 11 Stopping the HSP pump Lift the pump out of the pumping loca...
Page 25: ...ERVALS All maintenance must be complied with as they are scheduled in this manual The following table provides maintenance schedule for DYNASET HSP pumps CHECK POINTS After daily use If necessary Clea...
Page 26: ...our carrier machine To use special hydraulic fluids with DYNASET equipment please contact nearest DYNASET representative for an advice 6 3 CLEANING THE HSP PUMP ATTENTION Keep the HSP pump clean to en...
Page 27: ...ucked in the inlet chamber Run the pump in opposite direction Stop the HSP pump depressurize hydraulic system and prevent the system start Remove clogging by hand FAILURE REASON CORRECTIVE ACTION Liqu...
Page 28: ...28 Dynaset Oy Menotie 3 33470 Yl j rvi puh 03 3488 200 info dynaset com www dynaset com HYDRAULIC SUBMERSIBLE PUMPS MAINTENANCE...
Page 29: ...primary to the seller of the product Contact must be made as soon as possible latest thirty 30 days after the problem was identified Seller and or manufacturer technical staff determines the nature o...
Page 30: ...maintenance Cost of maintenance adjustments installation or startup Coating hydraulic oil quick couplings and interconnection hoses internal or external to system assemblies Products altered or modif...
Page 31: ...ible way Do not dispose used oils electrical components batteries or any other hazardous waste with normal waste They are harmful for the environment and can be recycled for re use Contact your local...
Page 32: ...Dynaset Oy Menotie 3 33470 Yl j rvi puh 03 3488 200 info dynaset com www dynaset com 32 HYDRAULIC SUBMERSIBLE PUMPS PRODUCT DISPOSAL...
Page 33: ...ent and Councils on the harmonization of the laws of Member States on the safety of machines Machine directive 2006 42 EC Applied conformity standards CEN EN ISO 4413 EN ISO 4413 2010 Hydraulic fluid...
Page 34: ...Dynaset Oy Menotie 3 33470 Yl j rvi puh 03 3488 200 info dynaset com www dynaset com 34 HYDRAULIC SUBMERSIBLE PUMPS DECLARATION OF CONFORMITY...
Page 35: ...BSP 1 Return line T BSP 1 2 BSP 1 2 BSP 3 4 BSP 3 4 BSP 3 4 BSP 3 4 BSP 1 Overflow BSP 3 8 BSP 3 8 BSP 3 8 HYDRAULIC POWER REQUIREMENTS Oil flow max l min gpm 38 10 03 40 10 56 50 13 20 100 26 42 169...
Page 36: ...Dynaset Oy Menotie 3 33470 Yl j rvi puh 03 3488 200 info dynaset com www dynaset com 36 HYDRAULIC SUBMERSIBLE PUMPS TECHNICAL SPECIFICATIONS...
Page 37: ...DYNASET OY all rights reserved...
Page 38: ...DF Hydraulic Drilling Fluid Pump JPL High Pressure Bin Washing System HSP Hydraulic Submersible Pump COMPRESSED AIR HK Hydraulic Piston Compressor HKL Hydraulic Rotary Vane Compressor HKR Hydraulic Sc...