E 25
5
Adjusting extendable parts
To ensure that the screed lays without
marks and the extendable parts can also
be adjusted to the various operating
conditions during use, the height of the
extendable parts can be adjusted.
A
The approach angle of the extendable
parts is pre-set in the factory.
Two spindles, with which the positioning
angle of the extendable parts can be ad-
justed in relation to the main screed with
a ratchet, are located on each extenda-
ble part.
The extendable parts are adjusted at the
factors in such a way that they are 3 mm higher on the inner and outer side than the
main screed. The scales (1) are set to "0" with this adjustment.
5.1
Setting the height of the extendable parts
If the extendable screed parts do not lay without marks, this can be corrected during
laying.
Turning the spindle (2) counter-clockwise with the ratchet lifts the extendable screed
parts. Turning clockwise lowers the extendable screed parts.
Anstell.tif
2
1
Summary of Contents for V5100TV-H
Page 2: ...www dynapac com...
Page 10: ...V 2...
Page 24: ...A 2...
Page 35: ...B 11 5 o 4 7 2 1 6 2 4 o 1 3...
Page 42: ...C 4 2 1 4 3...
Page 63: ...D 21 5 Screed heater PLC version 5 1 Switch cabinet for screed heater 40 43 44 42 41...
Page 65: ...D 23 5 2 Operating the control and monitoring unit 45 46 55 47 48 49 50 53 54 51 52...
Page 78: ...D 36 6 2 Operating the control and monitoring unit 100 101 110 102 103 104 105 108 109 106 107...
Page 94: ...D 52...
Page 100: ...E 6 Transport position 5 4 6 9 12 10 11 14 15 15 14 13...
Page 128: ...E 34 6 6 Material guide plate brace 1 2 3 3 4 6 5 7 9 8 10 11 II I 4...
Page 136: ...E 42...
Page 144: ...F 8 5 2 Guide tubes 1 1 2 2 2x 1 2...
Page 148: ...F 12 6 2 Cleaning the screed Emptying the tamper compartment 1 1 2 2 2a 1a 1a 3 4 3 4...
Page 163: ...F 27 14 2 PLC version gas heater Fuses in the switch cabinet of the screed heater A Fuses A...
Page 194: ...G 22...
Page 196: ...www dynapac com...