10.8 Faults in BOSS safety system
Fault
Possible cause
Remedy
No travel move-
ments; steering is
still possible
The operator is inside the safety field with
radio remote control
Leave the safety field
Radio remote control or receiver replaced
and safety field system subsequently not
taught
9.2 „Teaching the BOSS safety field
Front or rear safety device aerial not con-
nected properly or defective
Check the plug-in connection of the aer-
ials; replace if necessary
Distance between machine and radio
remote control is too great
Reduce the distance
Safety device control not connected prop-
erly or defective
Check the plug-in connection of the con-
trol; replace if necessary
Radio remote control defective
Have examined by a specialist; replace if
necessary
Wiring loom defective
Have examined by a specialist; replace if
necessary
Troubleshooting – Faults in BOSS safety system
D.ONE
163
Summary of Contents for D.ONE
Page 2: ...2...
Page 7: ...1 Introduction Introduction D ONE 7...
Page 11: ...2 Technical data Technical data D ONE 11...
Page 16: ...Technical data Noise data D ONE 16...
Page 17: ...3 Concerning your safety Concerning your safety D ONE 17...
Page 50: ...Concerning your safety Signage D ONE 50...
Page 51: ...4 Indicators and control elements Indicators and control elements D ONE 51...
Page 60: ...Indicators and control elements Remote control D ONE 60...
Page 61: ...5 Checks prior to start up Checks prior to start up D ONE 61...
Page 69: ...6 Operation Operation D ONE 69...
Page 95: ...7 Loading transporting the machine Loading transporting the machine D ONE 95...
Page 101: ...8 Maintenance Maintenance D ONE 101...
Page 142: ...Maintenance As required D ONE 142...
Page 143: ...9 Setting up refitting Setting up refitting D ONE 143...
Page 148: ...Setting up refitting Teaching the BOSS safety field system D ONE 148...
Page 149: ...10 Troubleshooting Troubleshooting D ONE 149...
Page 167: ...11 Disposal Disposal D ONE 167...
Page 169: ...12 Appendix Appendix D ONE 169...
Page 189: ......
Page 190: ......